SOLICITATION NOTICE
C -- 508-23-105 TDVV Repair Roofs Building 508C (VA-23-00003246)
- Notice Date
- 6/28/2022 11:35:51 AM
- Notice Type
- Presolicitation
- NAICS
- 541330
— Engineering Services
- Contracting Office
- 247-NETWORK CONTRACT OFFICE 7 (36C247) AUGUSTA GA 30904 USA
- ZIP Code
- 30904
- Solicitation Number
- 36C24722R0107
- Response Due
- 7/29/2022 11:00:00 AM
- Archive Date
- 10/27/2022
- Point of Contact
- Christopher Harper, Contract Specialist, Phone: 318-895-2366
- E-Mail Address
-
Christopher.Harper3@va.gov
(Christopher.Harper3@va.gov)
- Small Business Set-Aside
- SDVOSBC Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- Awardee
- null
- Description
- This acquisition is 100% restricted to Service-Disabled, Veteran-Owned Small Businesses (SDVOSB) THIS IS NOT A REQUEST FOR PROPOSAL. THIS IS A REQUEST FOR SF 330'S ARCHITECT/ENGINEER QUALIFICATION PACKAGES ONLY. ALL INFORMATION NEEDED TO SUBMIT SF 330 DOCUMENTS IS CONTAINED HEREIN. NO SOLICITATION PACKAGE WILL BE ISSUED IN THIS PHASE. THERE WILL BE NO SITE VISITS ARRANGED DURING THIS PHASE OF THE REQUIREMENT. THIS PROJECT IS SUBJECT TO AVAILABILITY OF FUNDS. The Government will not pay, nor reimburse, any costs associated with responding to this request. The Government is under no obligation to award a contract as a result of this announcement. The Department of Veterans Affairs Network 7 Contracting Office is seeking qualified Architect-Engineering (AE) firms to submit Standard Form 330 (SF 330) Architect/Engineering Statement of Qualifications for Project 508-23-105 TDVV Repair Roof Building 508C at Trinka-Davis Veteran s Village, located at 180 Martin Drive, Carrollton, GA 30117. Leaks were reported in all areas where terracotta roofing is installed. Leaks may be caused by poorly installed underlayment, water infiltration through ridge and hip nail holes, and condensation. The A/E is responsible for the quality of the design in accordance with a professional standard of care, VA standards, VA project-specific requirements, and applicable codes. A/E shall utilize Roof Assessment report which will be provided at a later date to the highest rated selected A/E firm. The A/E Services listed herein is being procured in accordance with the Federal Acquisition Regulation (FAR) 36.6 and VAAR 836.6. Firms submitting qualification packages must be fully licensed to perform designs as a registered professional AE firm in the United States to be considered for this opportunity. Also, see geographic location restriction in paragraph 4 of this notice. All submissions will be evaluated in accordance with the evaluation selection criteria as specified herein. Point of Contact: Christopher Harper, Email: Christopher.Harper3@va.gov Prospective Contractors are cautioned that proposal submitted in response to this solicitation must meet the criteria identified by 38CFR, Part 74. The SDVOSB concern agrees that in the performance of the contract, the concern will comply with the limitation on subcontracting requirements in accordance with VAAR Clause 852-219-10, VA Notice of Total Service-Disabled Veteran-Owned Small Business Set-Aside. For a Service-Disabled Veteran Owned Small Business (SDVOSB) to be considered as a prospective contractor, the firm, including Joint Ventures, must be verified and registered in the Department of Veteran Affairs (VA) Office of Small & Disadvantaged Business Utilization (OSDBU) Vendor Information Pages (VIP), VETBIZ (www.vip.vetbiz.gov, registered in the System for Award Management (SAM) database (www.sam.gov ) at time of submission of their qualification and reporting to VETS -4212 Federal Contractor Reporting in accordance with FAR 52.222-37, Employment Reports on Veterans at https://www.dol.gov/agencies/vets/programs/vets4212 . Failure of a prospective SDVOSB to be verified by the Center for Veterans Enterprise (CVE) at the time the SF 330 is submitted shall result in elimination from consideration. All Joint Ventures must be CVE verified at time of submission and submit agreements that comply with 13CFR 125.15 prior to contract award. A Firm Fixed Price A/E Design service contract is contemplated for Project #508-23-105 TDVV Repair Roof Bldg 508C, at Trinka-Davis Veteran s Village, Carrollton, GA. The NAICS Code for this procurement is 541330 Engineering Services and the annual small business size standard is $22.5M. The anticipated period of performance for completion of design is 175 calendar days after Notice to Proceed. The NAICS code for the anticipated Construction project is projected to be 236220 and magnitude of construction is predicted to be between $500,000 and $1,000,000. The area for consideration for this acquisition is restricted to A/E firms with an operating office located within 400 miles of Trinka-Davis Veteran s Village, 180 Martin Drive, Carrollton, GA 30117. Eligible prime contractor firms shall have a main and/or branch office geographically located within the 400 mile radius. The address of the main and/or branch office shall be documented on the SF 330. (Determination of mileage eligibility will be based off Google Maps) STATEMENT OF TASK/SCOPE OF WORK Architect Engineer (A/E) team, not limited to architects, engineers, and professional consultants shall provide design services for the development of specifications and drawings to correct the terracotta roof deficiencies outlined here within. Work includes but not limited to the following: Removal of all tile and associated flashings and underlayment; filling the gaps at the ridges/hips with spray foam insulation as required; installing a peel and stick membrane over the NailBase insulation; installing a vented deck system; applying a peel and stick membrane over the plywood substrate, and the re-install of the terracotta tile and associated flashing, metal flashing, vented eaves and ridge assemblies; as well as any other miscellaneous items as required to provide a watertight roof assembly. An assessment of the roof will be conducted to further determine which deficiencies will be addressed in this project. This design will include but not limited to the following disciplines: Architectural. This design shall follow all applicable VA guidelines, all applicable laws, NFPA codes, and standards. SELECTION CRITERIA: The A/E Source Selection Team shall utilize the following selection criteria in descending order of importance. Professional qualifications necessary for satisfactory performance of required service and working together as a team (in-house and/or consultants(s)). Provide brief resumes of proposed team members who will specifically serve as the Project Managers and Designers of Record. Note: The firm and A/E on staff representing the project or signing drawings in each discipline must be registered/licensed to practice in the United States. Provide your information on the SF 330 clearly marked by providing a current architect and/or engineering License numbers AND proof of Licensure. Specialized experience and technical competence in the type of work required, including, where appropriate on similar projects: experience in roofing repair, pollution prevention, waste reduction, and the use of recovered materials (include Government and private experience). Technical competence includes design quality management procedures, CADD, equipment resources, and laboratory requirements of the prime firm and any subcontractors. In addition, provide information on the effectiveness of the proposed project team (including management structure; coordination of disciplines, offices and/or subcontractors; and prior working relationships). Capacity to accomplish work in the required time. This factor evaluates firm's experience with similar size projects and the available capacity of key disciplines when evaluating the capacity of a firm to perform the work in the required time. The general workload and staffing capacity of the design office will be evaluated. List current projects with similar design fee being designed in the firms office. Indicate the firms present workload and the availability of the project team (including sub-consultants) for the specified contract performance period; Describe experience in successfully delivering projects per performance schedule, providing timely construction support, and successfully completing multiple projects with similar delivery dates. Past performance on contracts with Government agencies and private industry in terms of cost control, quality of work, and compliance with performance schedules. VISN 7 will evaluate past performance on recent and relevant contracts with government agencies (emphasis on VA work) and private industry in terms of cost control, quality of work, compliance with performance schedules and a record of significant claims against the firm due to improper or incomplete engineering services (references required). Recent is defined as performance occurring within 5 years of the date of this notice, except that ongoing projects must have begun no less than one (1) year prior to the issuance of this notice. Relevancy is defined as performance of work on projects that are similar in scope to the types of projects anticipated under the resultant contracts. Respondents with no previous past performance shall state this when addressing the selection criteria. Where there is no record of past performance, the proposal will be evaluated neither favorably nor unfavorably. Superior performance ratings on relevant projects may be considered more favorably in the evaluation. Submission Requirements: Submit a maximum of four (4) references; any of the following evaluations are acceptable: A-E Contractor Appraisal Support System (ACASS), Contractor Performance Assessment Report System (CPARS), or Past Performance Questionnaire (PPQ) evaluation for each project submitted under Criterion 2. If a completed CPARS evaluation is available, it shall be submitted with the completed SF330 package. If there is not a completed ACASS/CPARS evaluation, the PPQ included with this notice is provided for the Offeror or its team members to submit for each project included in criterion (2). If a PPQ is submitted, but an official ACASS/CPARS evaluation is found for that project in government databases, the official evaluation will take precedence. If an ACASS/CPARS evaluation is not available, ensure correct phone numbers and email addresses are provided for each contract customer/reference. Completed PPQs should be submitted with your SF330. A-Es should follow-up with references to ensure timely submittal of questionnaires. At the reference s request, questionnaires may be submitted directly to the Contracting Specialist Christopher Harper via email at Christopher.Harper3@va.gov, prior to the response date. A-Es shall not incorporate by references into their response ACASS/CPARS or PPQ evaluations previously submitted in response to other A-E services procurements. However, this does not preclude the Government from utilizing previously submitted PPQ information in the past performance evaluation. Submitted ACASS/CPARS and PPQ evaluations will not be counted as part of the page limitation and shall be attached to the SF330, behind the SF330 Part II document. Location in general geographical area and knowledge of the locality of the project and that your proximity to the general geographical area enables you to respond to emergency calls in person within 24 hours if required. (SF 330 submittal should show your knowledge of the locality of the project.) The area of consideration for offeror is a 400-mile driving radius between offeror location and the VA Medical Center referenced in paragraph 1 General Information. (Determination of mileage eligibility will be based on www.google.com) The extent to which potential contractors identify and commit to the use of service-disabled Veteran-owned small businesses, Veteran-owned small businesses, and other types of small businesses as subcontractors. Experience in construction period services to include professional field inspections during the construction period, review of construction submittals, support in answering requests for information during the construction period, and support of construction contract changes to include drafting statements of work, and cost estimates. A/E SELECTION PROCESS: a. This requirement is being procured in accordance with The Brooks Act of 1972, Federal Acquisition Regulation 36.6 (FAR) and VA Acquisition Regulation 836.6 (VAAR) and VA Acquisition Manual (VAAM) 836.6. Firms responding to this announcement by submitting a qualifying SF 330, before the closing date and time, will be considered for initial selection evaluation. Following initial evaluation of the SF330s received, three or more firms that are considered the most highly qualified to provide the type of services required will be selected for interviews. Selected firms will be notified by telephone or email of selection and provided further instructions. b. Selection and evaluation of firms shall be made based on SF 330 submissions and direct responses to the selection criteria identified herein. Failure to address all selection criteria will result in a decreased rating. c. Evaluating past performance and experience may include information provided by the firm, customer inquiries, Government databases, and Contracting Officer knowledge of current project performance. Failure to provide requested data, accessible points of contact or valid phone numbers could result in a firm being removed from consideration. d. Firms that design or prepare specifications in conjunction with this contract are prohibited from participating on any future construction contracts based on those documents. All projects identified on the SF330 must be completed by the office/branch/individual team member performing the work under this contract. SUBMISSION CRITERIA/REQUIREMENTS: The SF 330 form may be downloaded from http://www.gsa.gov/portal/forms/type/SF Completed SF 330 s shall include the primary firms, subcontractor firms and any consultants expected to be used on the project. Do not submit information incorporating by reference. Prospective firms shall address all selection criteria factors within their submitted SF330 packages. The following format shall be used: (1) Cover Page with Solicitation Number, Project Title (2) Table of Contents (3) SF 330 s (4) Copy of Current A/E state Engineer/Architect License (5) Copy of current vetBiz.gov SDVOSB certification (6) Unique Entity Identifier (UEI) Number (7) Tax ID number (8) The E mail address and Phone number of the Primary Point of Contact. b. SF 330 Date of Receipt/Due Date: Interested firms having the capabilities to perform this work must submit one (1) electronic SF 330 and attachments (if any) no later than (NLT) 2:00 PM EST, 29 JULY 2022. Email capacity is limited to five (5) to seven (7) megabyte (Megs). c. All SF330 submittals and questions must be sent electronically to the attention of Christopher Harper, Contracting Specialist at Christopher.Harper3@va.gov . DO NOT SEND HARD COPIES. Please provide Pre-Solicitation Number, Project Title, and Firm Name in Subject Line of email. When submitting SF330s, if more than one email is sent, please number emails in Subjects as 1 of n . Submittals received after the date and time identified on page one (1) will not be considered. Firms not providing the required information may be negatively evaluated. Facsimile submittals will not be accepted. All information must be included in the SF330. d. The SF-330 including title page, table of contents, and any other relevant information shall not exceed a total of 50 pages in a common font size 12 font, single spaced. The proposal shall be submitted as a single application-generated (not scanned), searchable PDF document. A page is defined as each face of an 8.5 X 11-inch sheet of paper containing information. The page limitation does not apply to the licenses, contract performance evaluations, (i.e. CPARS) and award documentation. This information should be provided as attachments to the SF 330. It is the offeror s responsibility to check the Federal Business Opportunities website at: www.fbo.gov for any revisions to this announcement prior to submission of SF330s.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/908c6818d3414b78a2fef678a49c5b6b/view)
- Place of Performance
- Address: Trinka-Davis Veteran's Village 180 Martin Drive Carrollton, GA 30117
- Zip Code: 30117
- Zip Code: 30117
- Record
- SN06371385-F 20220630/220628230123 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |