Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JUNE 30, 2022 SAM #7517
SOURCES SOUGHT

65 -- STRYKER BEDS FOR CLC

Notice Date
6/28/2022 4:16:44 PM
 
Notice Type
Sources Sought
 
NAICS
339113 — Surgical Appliance and Supplies Manufacturing
 
Contracting Office
246-NETWORK CONTRACTING OFFICE 6 (36C246) HAMPTON VA 23667 USA
 
ZIP Code
23667
 
Solicitation Number
36C24622Q0651
 
Response Due
7/5/2022 12:00:00 PM
 
Archive Date
07/20/2022
 
Point of Contact
LaToya Glover, Contract Specialist, Phone: 910-488-2120 x-5823
 
E-Mail Address
LaToya.Glover2@va.gov
(LaToya.Glover2@va.gov)
 
Awardee
null
 
Description
This is sources sought announcement only. The purpose of this notice is to conduct market research and obtain information from qualified businesses with special interest in seeking: VA certified Service-Disabled Veteran owned Business (SDVOSB); Veteran Owned Small Business (VOSB) and Small Business for small business concerns. No solicitation is being issued at this time. This notice shall not be construed as a commitment by the Government to ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. Your responses will be due by Tuesday, July 05, 2022 3:00PM (EST) to the point of contact listed below. All information submitted in response to this announcement is voluntary; the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government. The U.S. Department of Veterans Affairs, Network Contracting Office 6, and the Durham Veterans Affairs Medical Center anticipate a delivery for several Hospital Beds. This is a VHA Directive requirement for the facility to obtain equipment. Equipment: Essential physical characteristics for Durham VA bed requirements: o Bed weight limit of patients up to 500 pounds o Equipped with an In-bed scale o The bed should be capable of descending a minimum 12-15 from the floor for safe/ease of egress o Bed sensing system that identifies object beneath frame and prevents crush injury from floor surface/and bed deck upon descent o The Bed retracted length should not exceed 91 inches o The Bed should have touch screen controls on both sides, to offer control and access for caregivers/intuitive, non-complex control systems o Bed frame must be open architecture o The Bed/Mattress/support surface should have mechanism/technology that addresses weight-based pressure redistribution, shear, friction, patient migration with clinical indications up to and including stage 4 pressure injuries. Preferred option: Able to incorporate low air loss to provides moisture vapor/heat transfer with microclimate surface o The Bed must have quick release CPR function o The Bed must meet national safety standards regarding interface of both patient and caregiver, with FDA side rail and entrapment issues. Reference: FDA/Hospital Bed System Dimensional and Assessment Guidance to Reduce Entrapment. o Safety: Access with portable Hoyer lift/Evacu-Sled devices o The Bed to tolerate hospital grade cleaning disinfectants o The bed should have Motorized-drive with Variable Speed control mechanisms with steering controls o Brakes: Head/foot brake system o Preferred: Bed deck with non-solid sheeting o Preferred: Under bed lighting o Services or Performance required: 1 yr vendor maintenance coverage o Requesting trade-in allowance Place of Delivery: Durham VAMC 508 Fulton Street Durham, NC 27705 The appropriate NAICS Code 339113 and the small business size standard are 750 interested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications in conjunction with FAR 4.11 required registration in the System for Award Management (SAM) database prior to award of a contract. ALL INQUIRIES SHALL BE MADE TO: Contracting Specialist: LaToya Glover; NCO 6, Durham, North Carolina; email: LaToya.Glover2@VA.GOV
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/01941b1f3fee48c892c2ad43f9082be9/view)
 
Place of Performance
Address: Durham VAMC 508 Fulton Street, Durham 27705
Zip Code: 27705
 
Record
SN06372413-F 20220630/220628230130 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.