SOLICITATION NOTICE
Y -- PROJECT 526-15-112 Renovate and Modernize E.R.
- Notice Date
- 6/29/2022 2:29:04 PM
- Notice Type
- Solicitation
- NAICS
- 236220
— Commercial and Institutional Building Construction
- Contracting Office
- 242-NETWORK CONTRACT OFFICE 02 (36C242) ALBANY NY 12208 USA
- ZIP Code
- 12208
- Solicitation Number
- 526-15-112
- Response Due
- 8/1/2022 11:00:00 AM
- Archive Date
- 08/30/2022
- Point of Contact
- Patricia Cordero, Contracting Officer, Phone: (718) 584-9000 x4928
- E-Mail Address
-
patricia.cordero@va.gov
(patricia.cordero@va.gov)
- Small Business Set-Aside
- SDVOSBC Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- Description
- Statement of Work Project # 526-15-112 Renovate and Modernize E.R. IFB#: 36C24222B0004 The renovation of an approximately 9000 S.F. space on the 1st floor F Wing of the Main Hospital (Building 100) of the James J. Peters VA Medical Center to completely renovate the existing Emergency Department.� The work will be phased as shown on the contracting drawings and work must be done with minimal disruption to the surrounding areas. The work includes but not limited to the construction of barriers to comply with infection control and life safety regulations, selection demolition, general carpentry, electrical, plumbing and med-gas, fire protection and detection, HVAC, telecommunication, security systems, installation of millwork and/or casework, and interior finish work in accordance to the supplied specifications and drawings. In addition to the work laid out by the contract documents, the contractor shall also include the replacement of the Emergency Room outer canopy.� This shall include the demolition of the existing canopy and an installation of a new canopy that will cover almost the entire the sidewalk section outside the ER, especially the new ambulance entrance.� The contractor shall provide engineered shop drawings for this canopy and shall include electrical work to replicate optimal lighting conditions under the canopy as well as a lit �Emergency Room� sign.� Prior to installing the canopy, the contractor shall replace the sidewalk and curb outside the emergency room, taking care not to damage the top of the Breeching Tunnel nor the fresh air intakes.� The 6� steel tube columns can be rehabbed and reused if desired.� A template of canopy can be provided upon request, but the contractor can submit their own proposed template for approval. Anteroom and smoke barrier wall will be constructed along the perimeter of the project before any construction work commences.� All proper infection control and life safety measure will be provided and coordinated with Infection Control and Safety Officer. Work is expected to be completed within __760____ calendar days from NTP SEE ACTUAL SOLICITATION FOR ADDITIONAL INFORMATION
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/e78bc51137cb4eb1a8eed5ca9552c924/view)
- Place of Performance
- Address: Bronx, NY 10468, USA
- Zip Code: 10468
- Country: USA
- Zip Code: 10468
- Record
- SN06373302-F 20220701/220629230106 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |