SOLICITATION NOTICE
66 -- Bruker MALDI-TOF instrument maintenance
- Notice Date
- 6/30/2022 7:22:40 AM
- Notice Type
- Solicitation
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- NAVAL MEDICAL RESEARCH CENTER DET DPO AA 34031-0008 USA
- ZIP Code
- 34031-0008
- Solicitation Number
- BAC220009
- Response Due
- 7/14/2022 9:00:00 AM
- Archive Date
- 07/29/2022
- Point of Contact
- Genaro M Vasquez, Phone: 0115116144128
- E-Mail Address
-
genaro.m.vasquez.ln@mail.mil
(genaro.m.vasquez.ln@mail.mil)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Description
- Complete Maintenance in LIMA,PERU Agreement includes: -Onsite response of Three (3) Business Days: Monday-Friday 8:30am-5pm. - 1 (One) Planned Maintenance (PM) visits per year with complete inspection of listed instrumentation -Unlimited onsite emergency service visits -Parts, labor, travel. Exclusions noted in the Terms and Conditions. -Software Upgrades. Bruker proprietary software only, excludes 3rd party software; excludes hardware necessary to upgrade system compatibility - 1 (One) cleaning visit or 1 (One) additional PM will be inclusive after a technical expert recommends a cleaning or PM on the contracted system Additionally provide a Hotline number for applications /technical service during normal business hours; Technical support hotline outside normal business hours of 5PM-12AM EST weekdays, 9AM -9PM EST on weekends and holidays. Any other than the included PM /cleanings visits will be sold separately. Parts exclusions are noted in the Terms and Conditions. FIRST LINE OF SUPPORT IS VIA A REMOTE ACCESS: If remote access is not available , response time and/or repair will be delayed to a minimum of 2 business days. Response time begins once a certified Bruker engineer diagnoses the system and recommends a visit. Service response excludes weekends, company and local public holidays. For IVD/ CA system, software and library are registered/ approved and cleared for use with registered/ approved Bruker CARE products. The use of non-Bruker reagents and consumables is therefore not permitted and is consequently leading to immediate invalidity of this contract. In this case contract fees will not be reimbursed.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/443b778620164ccb8e52202b786d9b19/view)
- Place of Performance
- Address: LIMA, PER
- Country: PER
- Country: PER
- Record
- SN06375828-F 20220702/220630230211 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |