SOLICITATION NOTICE
W -- ELECTRIC HIGH PRESSURE AIR COMPRESSOR RENTAL
- Notice Date
- 7/19/2022 8:23:19 AM
- Notice Type
- Solicitation
- NAICS
- 532490
— Other Commercial and Industrial Machinery and Equipment Rental and Leasing
- Contracting Office
- PORTSMOUTH NAVAL SHIPYARD GF PORTSMOUTH NH 03801-5000 USA
- ZIP Code
- 03801-5000
- Solicitation Number
- N3904022RC20254
- Response Due
- 7/21/2022 9:00:00 AM
- Archive Date
- 08/05/2022
- Point of Contact
- Bob Watters, Phone: 2074382205
- E-Mail Address
-
robert.watters@navy.mil
(robert.watters@navy.mil)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Description
- 5000 PSI Electric High Pressure� Air Compressor� The unit is to be an air cooled High Pressure Air Compressor with controller to deliver oil free air at 5000 psi. The unit is to be electric driven, self contained, skid mounted with all necessary filters, dryers, and instruments to deliver 4500 psi, oil free air at dew point of -80 degrees F at atmosphere. The compressor shall be equipped with a moisture separator and air dryer capable of drying 18 CFH to a dew point of -80 degrees F at atmosphere. All assemblies shall be connected to enable single point connection by the shipyard. The compressor is to compress free air from the atmosphere to 5000 psig, deliver 100% oil free air at a rated discharge capacity of 30 CFH @ 3000 PSIG and 18 CFH @ 5000 PSIG, and must be capable of continuously supplying the specified quantity of air at the discharge pressure. 1.5 cubic foot, 7000 PSI ASME receiver with safety relief valve, drain valve and 1/2"" NPT discharge line service valve The unit is to be equipped with an integral after cooler, to deliver air under 100 degrees F, and enclosed in a weather proof enclosure Must have a purification system consisting of a dehydration/purification rack, priority valve, upstream and downstream pressure gauges and drain. One mechanical separator and two coalescing filters remove oil and water droplets. Six molecular sieve cartridges remove oil and water vapors. Each cartridge must have a particulate filter to prevent passage of particles downstream. The coalescing filters need a manual filter drain piped into the condensate tank for collection and disposal. Motor is to be 460VAC, 3 Phase, 60 cycle, the starter is to be a pre-wired, soft start, closed transition type. The motor to be suited for operation in an outdoor industrial pier side environment in 0 degrees F temperatures without the need for additional shelter. The motor is to be air cooled. The unit shall be wired electrically to enable a single point shipyard connection and equipped with 50 ft. of properly sized cable. Period of Performance (Base) 8/1/22-4/23/23 Period of Performance (Option) 4/24/23-5/21/23 Place of performance is: Naval Base Point Loma, San Diego, CA
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/9ef82aba6505468bb12ce8ade7055b1d/view)
- Place of Performance
- Address: San Diego, CA 92106, USA
- Zip Code: 92106
- Country: USA
- Zip Code: 92106