Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JULY 22, 2022 SAM #7539
SOURCES SOUGHT

65 -- Biosense Webster Cardiac catheters and supplies

Notice Date
7/20/2022 10:06:14 AM
 
Notice Type
Sources Sought
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
W40M USA HLTH CONTRACTING ACT JBSA FT SAM HOUSTON TX 78234-0000 USA
 
ZIP Code
78234-0000
 
Solicitation Number
W81K0022Q0167
 
Response Due
7/26/2022 8:00:00 AM
 
Point of Contact
Cathy Harris, Phone: 2102213245
 
E-Mail Address
cathy.l.harris2.civ@mail.mil
(cathy.l.harris2.civ@mail.mil)
 
Description
The purpose of this sources sought notice is to conduct market research to determine if responsible sources exist by ascertaining if this effort can be successfully competed and/or set-aside for Small Businesses. The proposed North American Industry Classification System (NAICS) Code is 339112 - Surgical and medical Instrument Manufacturing with a corresponding size standard of 1,000 employees. The Government will use this information to determine the best acquisition strategy for this procurement. The Government is interested in all large and small businesses to include 8(a), Service-Disabled Veteran- Owned, HubZone, and Women-Owned small business concerns. The Regional Health Contracting Office - Central, JBSA, Fort Sam Houston, Texas, is seeking potential sources to provide catheters and supplies which are compatible with the CARTO3 XP EP Navigation and Ablation System and software currently owned by Brooke Army Medical Center (BAMC). These products are required for treatment of electrical arrhythmias of the heart and are regularly used during cardiology procedures for patients at the San Antonio Military Medical Center (SAMMC), JBSA - Fort Sam Houston, Texas. Vendor responses should include: 1) Organization name, address, e-mail address, Web site address, telephone number, and size (small versus large business, and any other socio-economic categories) and type of ownership for the organization; 2) Tailored capability statements addressing the salient characteristics listed, with appropriate documentation supporting capability. a. The catheters must interface directly with the existing Biosense Webster CARTO3 System. b. The catheters must allow the operator to perform fast anatomical mapping (FAM) and allow for instantaneous catheter localization with accuracy of +/- 1mm. All catheters manufactured by Biosense Webster are proprietarily manufactured for compatibility and use with the CARTO3 System for diagnostic, ultrasound, and therapeutic purposes. c. The catheters must be sensor based and allow for fast anatomical map development with map activation and voltage data collection. d. These catheters are regular expendable proprietary items which are fundamentally Designed to interface via direct connection with the Biosense Webster CARTO3 System Patient Interface Unit (PIU). e. The inherent design of the Multi electrode mapping catheters must be linked to CARTO MEM proprietary software of the CARTO3 system, which allows for the simultaneous acquisition of up to 20 highly accurate activation points (point-to-point map) for maximized speed, accuracy and efficiency in mapping complex atrial and ventricular circuits. f. The Soundstar ultrasound catheters must provide the ability to visualize and mark cardiac anatomy through the CARTO3 System and afford the ability to visualize the tip of the ablation catheter via the ultrasound image using the tip to tissue overlay feature. g. The ablation catheters must be capable of a direct interface with the CARTO SmartTouch Catheter ablation System and able to receive continuous peristaltic pumping heparinized irrigation solution, and variable power delivery in conjunction with this proprietary system. h. The SmartTouch Catheters must provide force contact parameters and visitag integration with the CARTO3 System reflecting real time force contact information and ablation characteristics that better inform the physician's ablation strategy and delivery of lesion set which are designed for use with the CARTO3 System and SmartAblate Generator System. This is not a solicitation. This information is for planning purposes only and is not to be construed as a commitment by the Government, implied or otherwise, to issue a solicitation or award a contract. Vendors responding to this sources sought notice are advised their response does not ensure participation in future solicitations or contract awards. The Government will not reimburse any company or individual for any expense associated with preparation or participation in this research. Interested parties should e-mail responses to cathy.l.harris2.civ@mail.mil by the date identified below. Hard copies of the responses are not required and will not be accepted. Submit your response no later than 26 Jul 2022 by 10:00 noon CST.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/1a6b09a94da5476ebc17100388f7ab52/view)
 
Place of Performance
Address: JBSA Ft Sam Houston, TX 78234, USA
Zip Code: 78234
Country: USA
 
Record
SN06396329-F 20220722/220720230119 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.