SOLICITATION NOTICE
X -- U.S. Government Seeks to Lease Office and Related Space in Queens / Western Long Island, New York
- Notice Date
- 7/25/2022 6:02:16 AM
- Notice Type
- Presolicitation
- NAICS
- 531120
— Lessors of Nonresidential Buildings (except Miniwarehouses)
- Contracting Office
- PBS CENTRAL OFFICE - BROKER SVCS WASHINGTON DC 20405 USA
- ZIP Code
- 20405
- Solicitation Number
- 3NY0743
- Response Due
- 8/15/2022 2:00:00 PM
- Point of Contact
- Vincent LaManna, Phone: (631) 370- 6046
- E-Mail Address
-
Vincent.LaManna@cbre.com
(Vincent.LaManna@cbre.com)
- Description
- General Services Administration (GSA) seeks to lease the following space: State: New York City:�Queens, Western Long Island Delineated Area: From the point of beginning (POB): 159th Street and Rockaway Blvd, Queens, NY Portions of Queens and Western Long Island, New York roughly bounded by College Point to the Northwest, John F. Kennedy International Airport to the Southwest, Baldwin to the Southeast and Spinney Hill to Northeast. Please see attached Map Minimum Sq. Ft. (ABOA):�42,739 Maximum Sq. Ft. (ABOA):�61,055 Space Type:�Office and related space Parking Spaces (Total):�175 - 250 (secured, reserved for the exclusive use of the Government). The Government requires up to 7 electric vehicle charging stations as part of its parking requirement. Parking Spaces (Surface):�Either Parking Spaces (Structured):�Either Parking Spaces (Reserved):�175 - 250 Full Term:�20 Years Firm Term:�20 Years Option Term:�N/A Additional Requirements: If offered space is not on the first floor, a minimum of 2 passenger elevators or three (3) passenger elevators with one passenger elevator as a combination passenger/freight elevator. If not dedicated for the Government�s sole use, the elevators must allow for the Government to control access to Government occupied floors by card access control, destination dispatch, or other methods acceptable to the Lease Contracting Officer (LCO). If the offered space is not on the first floor, the offeror shall provide a freight elevator approximately 6' X 8' having a minimum 3500 lb. capacity near the warehouse area and loading dock. If not dedicated for the Government�s sole use, the freight elevator must allow for the Government to control access to Government occupied floors by card access control, destination dispatch, or other methods acceptable to the LCO. Ceilings shall be at a minimum 9 feet and 0 inches and no more than 12 feet and 0 inches measured from floor to the lowest obstruction. The offeror must ensure floor is capable of supporting installation of High density file rooms and associated high density file cabinets. Examples of these filing systems are as follows: Lektriever Type Units: Megastar MegaLift VLM (800-701-1908), 117.5"""" x 130"""" x 135"""", Model: 15654/25B/3410, 3/PE 208V, 17 A, 60Hz #1 MegaStar Media Station 125 (800-701-1908), 128.7"""" x 57.37"""" x 107.28"""", Model: SYS-120-1661-US,2/PE 110 V, 18 A, #2 Hanel Rotomat 700, 116"""" x 56.5"""" x 106"""", 1P 110V, 36.4A, #3 Hanel Rotomat 400, 102.5"""" x 52.5"""" x 104"""", 1P 110V, 22.4A, #4 Kardex Series 2000, 102"""" x 59.75"""" x 95.5"""", 120V, 15A. The building must provide a minimum area of 6� x 15� for a metal detector and X-ray unit in the public area on the lowest floor of occupancy or near the first-floor lobby area. The building must accommodate a smoking pavilion, subject to local ordinance. The building�s HVAC system shall be capable of providing an amount of fresh air ventilation to minimize indoor air recirculation, per CDC COVID-19 Employer Information for Office Buildings. The building HVAC systems shall have the capacity to employ internal technology to minimize airborne particles, for example HEPA/MERV-13 filters in addition to UV-C lights, to minimize the spread of airborne pathogens through recirculated air. The building must have a truck (semi-trailer, 18 wheeler, etc.)-level loading dock bay with access to the freight elevator. The loading dock must have a ramp that is suitable to allow a 6K forklift to get on and off the loading dock, OR a material lift at the loading dock. The building must provide space and access for a backup generator pad with approximate sizing of 202�x96�. The offeror must provide 500NSF interior storage space within a 50 foot proximity to the loading dock and freight elevator for pallets and oversized items, acceptable to the LCO. The 500 NSF storage space is considered a part of the Government�s usable square footage. The building must provide antennae and satellite space on the roof. Minimum structural capacity of roof slab around antennae/satellite location shall be uniform live load of 100 pounds per square foot. The Facility must allow for installation of a minimum of seven (7) electrical vehicle charging stations servicing fourteen (14) parking spaces, included in its parking spaces indicated above. The building must not be more than � mile proximity to public transportation accessible by continuous sidewalks, walkways, or pedestrian crosswalks. The primary functional entrance of the Building shall be within safely accessible, walkable 2,640 foot (1/2 mile) distance of at least FIVE (5) instances of amenities, two of which must be inexpensive or moderately priced fast-food or eat-in restaurants.� The remaining THREE (3) instances must fall within at least 2 of the Diverse Use Categories shown below: Food Retail - Supermarket, Other food store with produce Community-Serving Retail - Clothing store or department store selling clothes, Convenience store, Farmer�s market, Hardware store, Pharmacy, Other retail Services - Bank, Gym, Health club, Exercise studio, Hair care, Laundry, Dry cleaner, Restaurant, Caf�, Diner (excluding establishments with only drive-through) Civic and Community Facilities: Adult or senior care (licensed), Child care (licensed), Community or recreation center, Cultural arts facility (museum, performing arts), Educational facility (including K�12 school, university, adult education center, vocational school, community college), Family entertainment venue (theater, sports), Government office that serves public on-site, Place of worship, Medical clinic or office that treats patients, Police or fire station, Post office, Public library, Public park, Social services center To be considered, amenities must be accessible from the Building by continuous sidewalks, walkways, or pedestrian crosswalks.� Amenities must be existing or the Offerors must demonstrate to the Government�s reasonable satisfaction that such amenities will exist by the Government�s required occupancy date. The building must meet the Facility Security Level (FSL) 3 security requirements as set forth by FAA Order (FAO) 1600.69C, Facility Security Management Program (FSMP). FSL III Security requirements are available upon request. The offeror must provide a current full set of construction documents in AutoCAD including, but not limited to architectural, mechanical, electrical, plumbing, fire protection, structural, and site plans. To the extent a requirement referenced in this section conflicts with any other requirement of the Market Survey, the more stringent shall apply. Offered space must meet Government requirements for fire safety, accessibility, seismic, and sustainability standards per the terms of the Lease.� A fully serviced lease is required.� Offered space shall not be in the 100 year flood plain. The ABOA square footage range noted above will be finalized after the market survey date noted below but prior to the issuance of the Request for Lease Proposals. Entities are advised to familiarize themselves with the telecommunications prohibitions outlined under Section 889 of the FY19 National Defense Authorization Act (NDAA), as implemented by the Federal Acquisition Regulation (FAR).� For more information, visit: https://acquisition.gov/FAR-Case-2019-009/889_Part_B. Expressions of Interest Due:�August 15, 2022 Market Survey (Estimated):�September 7 - 9, 2022 Occupancy (Estimated):�April 3, 2025 Send Expressions of Interest to: Vincent LaManna, First Vice President CBRE Advisory & Transaction Services 58 S. Service Road, Suite 410 Melville, NY 11747 Office:�(631) 370-6046 Email Address:�vincent.lamanna@cbre.com Government Contact Information: GSA Lease Contracting Officer -�Eduardo Vidal CBRE Local Brokers -�Vincent LaManna, Ralph Guiffre and Richard Freel CBRE Transaction Manager - Maria Kobe
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/c77f6f88f0464eedab68de6b25030ec7/view)
- Place of Performance
- Address: USA
- Country: USA
- Country: USA
- Record
- SN06400500-F 20220727/220725230108 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |