Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JULY 29, 2022 SAM #7546
SOURCES SOUGHT

66 -- Fluke Networks DSX2-8000QI for the Northport VAMC

Notice Date
7/27/2022 12:40:29 PM
 
Notice Type
Sources Sought
 
NAICS
334515 — Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals
 
Contracting Office
242-NETWORK CONTRACT OFFICE 02 (36C242) ALBANY NY 12208 USA
 
ZIP Code
12208
 
Solicitation Number
36C24222Q1024
 
Response Due
8/1/2022 1:00:00 PM
 
Archive Date
08/04/2022
 
Point of Contact
Jonatan Rondon, Contract Specialist, Phone: 212-686-7500 6490
 
E-Mail Address
jonatan.rondon@va.gov
(jonatan.rondon@va.gov)
 
Awardee
null
 
Description
TITLE: 38-Sources Sought Notice SOL: 36C24222Q1024 DUE: 08/1/2022 at 16:00 EST NAICS: 334515 AGENCY: Department of Veterans Affairs, Northport VA Medical Center 79 Middleville Road Northport, NY 11768. POC: Jonatan Rondon Email all responses only to: Jonatan.rondon@va.gov DESCRIPTION: This Sources Sought Notice is for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time. This notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine interest and capability of potential qualifications of all businesses relative to the North American Industry Classification Code (NAICS) 334515. The Department of Veteran s Affairs is seeking all qualified business manufacturer or distributors of small business manufacturers to all the following specifications: Requirement: The Northport VA Medical Center Engineering department is looking to acquire the new Fluke Networks DSX2-8000QI by TEquipment, this is the preferred equipment as engineering staff has deemed it the right equipment for their hospital s need. However, the Service will accept Brand Name or equal based on the desired characteristics and specifications below. Contractor is to provide the following: Fluke Networks DSX2-8000QI Versiv 2 CableAnalyzer w/Quad OLTS and Fiber Inspection, Integrated Wi-Fi Versiv modular design supports copper certification, fiber optic loss, OTDR testing and fiber end-face inspection Unmatched speed for Cat 6A, 8, Class FA, I/II and all current standards ProjX system manages job requirements and progress from set-up to systems acceptance, making sure all tests are completed correctly Taptive user interface simplifies set-up, and eliminates errors Analyze test results and create professional test reports using LinkWare management software Graphically displays the source of failures including crosstalk, return loss and shield faults for faster troubleshooting Intertek Verified to TIA Level 2G the most stringent accuracy requirement Complete testing for your Industrial Ethernet copper cabling Specifications: DSX2-8000 Performance Specifications Category 8 test modes (or lower link categories) ANSI/TIA-1152 Level 2G Class I/II test modes Proposed standard IEC 61935-1 Ed. 5 Level VI Length of Twisted Pair Cabling1 Without Remote With Remote Range 800 m (2600 ft) 150 m (490 ft) Resolution 0.1 m or 1 ft 0.1 m or 1 ft Accuracy ± (0.3 m + 2 %); 0 m to 150 m ± (0.3 m + 2 %) ± (0.3 m + 4 %); 150 m to 800 m Propagation Delay Without Remote With Remote Range 4000 ns 750 ns Resolution 1 ns 1 ns Accuracy ± (2 ns + 2 %); 0 ns to 750 ns ± (2 ns + 2 %) ± (2 ns + 4 %); 750 ns to 4000 ns Delay Skew Range 0 ns to 100 ns Resolution 1 ns Accuracy ± 10 ns DC Loop Resistance Test Range 0 to 540 Resolution 0.1 Accuracy ± (1 + 1 %) Overload recovery time Less than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage. Fluke Networks CertiFiber Pro Optical Loss Test Set Specifications Power Meter Specifications Input Connector Interchangeable connector adapter (LC standard, SC, ST and FC optional) Detector Type InGaAs Wavelengths 850 nm, 1300 nm, 1310 nm, 1550 nm Power Measurement Range 0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths) Power Measurement Uncertainty1,2 -5 dBm <0 dBm SMF-28 singlemode fiber Continuous wave SC/UPC connector Operating Wavelength 650 nm nominal Output Modes Continuous wave Pulsed mode (2 Hz to 3 Hz blink frequency) Connector Adapter 2.5 mm universal Laser Safety Class II CDRH Over operating temperature range Environmental Specifications Title Requirement Operating Temperature -18° C to 45° C Storage Temperature -30° C to +60° C Operating Relative Humidity 0 % to 90 %, 32 °F to 95 °F (0° C to 35° C) % RH without condensation 0 % to 70 %, 95 °F to 113 °F (35° C to 45° C) Vibration Random, 2 g, 5 Hz-500 Hz Shock 1 m drop test with and without module and adapters Safety CSA C22.2 No. 1010.1: 1992 EN 61010-1 1st Edition + Amendments 1, 2 Pollution Degree 2 Altitude Operating: 4,000 m; storage: 12,000 m EMC EN 61326 1 THIS IS NOT A SOLICITATION AND DOES NOT OBLIGATE THE GOVERNMENT TO ISSUE A SOLICITATION. Please be advised that the Government will not pay for any information submitted under this announcement. The applicable North American Classification System (NAICS) Code for this requirement is 334515 (Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals). Response Email should contain the following information: Name of firm, Socio-Economic category of the firm, complete address, phone & fax number of contacts.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/8104993a72424233947f8d1f99d6751a/view)
 
Place of Performance
Address: Northport VA Medical Center 79 Middleville Road, Northport, NY 11768, USA
Zip Code: 11768
Country: USA
 
Record
SN06404624-F 20220729/220727230121 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.