SOLICITATION NOTICE
D -- SUBMIT A QUOTE TO: 1. PROVIDE, INSTALL, AND MAINTAIN A 10MB FIBER CIRCUIT LOCATED AT THE DELAWARE AIR NATIONAL GUARD BASE, BLDG 2902, AT 2902 SPRUANCE DR, NEW CASTLE, DE 19720.
- Notice Date
- 7/28/2022 11:43:28 AM
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 517311
— Wired Telecommunications Carriers
- Contracting Office
- TELECOMMUNICATIONS DIVISION- HC1013 SCOTT AFB IL 622255406 USA
- ZIP Code
- 622255406
- Solicitation Number
- HC101322QA416
- Response Due
- 8/29/2022 3:00:00 PM
- Archive Date
- 08/29/2023
- Point of Contact
- Amanda Romanitis, Phone: 6184186557, George C. Butler, Phone: 6184186707
- E-Mail Address
-
amanda.m.romanitis.civ@mail.mil, george.c.butler4.civ@mail.mil
(amanda.m.romanitis.civ@mail.mil, george.c.butler4.civ@mail.mil)
- Description
- SUBMIT A QUOTE TO: 1. PROVIDE, INSTALL, AND MAINTAIN A 10MB FIBER CIRCUIT LOCATED AT THE DELAWARE AIR NATIONAL GUARD BASE, BLDG 2902, AT 2902 SPRUANCE DR, NEW CASTLE, DE 19720. 2. ESTABLISH TSP FOR THIS SERVICE. 3. CIRCUIT ID: TBD 4. DHCP IS BEING REQUESTED FOR THIS SERVICE. 5. THE GOVERNMENT IS REQUESTING THE VENDOR (TECHNICIAN) TO INSTALL A NEW LINE (JACK) FROM THE NETWORK INTERFACE DEVICE (NID) TO THE USER LOCATION. THIS WILL ASSURE THAT THIS NEW SERVICE WILL NOT AFFECT ANY CURRENT SERVICES AT THE LOCATION. 6. NID MUST CONVERT CIRCUIT FROM FIBER TO BE AN ETHERNET HAND OFF. ***REMARKS*** 1. CONTRACTOR MUST CONTACT THE SITE POC(S) AT LEAST 72 HRS PRIOR TO INSTALLATION. 2. CONTRACTOR MUST CALL DISA NOSC 202-757-6001 AT LEAST 72 HRS PRIOR TO MAINTENANCE. 3. CUSTOMER WILL ACCEPT EARLIEST POSSIBLE INSTALL DATE. (SIP) 4. THIS IS A CANDIDATE FOR RESTORAL TELECOMMUNICATIONS SERVICE PRIORITY (TSP). 5. SERVICE AVAILABILITY 99.5% OR BETTER, WITH 30 MINUTE RESPONSE; 2 HOUR RESTORAL; UPDATES PROVIDED EVERY 60 MINUTES UNTIL CIRCUIT IS FULLY TESTED AND OPERATIONAL. VENDOR MUST HAVE 24 HOUR MONITORING FACILITIES AND EQUIPMENT TO TROUBLESHOOT PATH AND ASSOCIATED EQUIPMENT AFTER INSTALLATION. 6. COMPLETE OUTAGE: INTERFACE OR PROTOCOL NON-OPERATIONAL RESPONSE TIME FROM INITIAL REPORT OR DETECTION OF CIRCUIT DOWN WILL BE 30 MINUTES AND THE MEAN RESTORE TIME TO REPAIR (MTTR) MUST BE 120 MINUTES. 7. IMPAIRMENT: IMPAIRED THROUGHPUT OR IMPAIRED CIRCUIT OPERTION (EG. LATENCY ISSUES, INTERMITTENTLY FLAPPING/BOUNCING, INTERMITTENT ISSUES) RESPONSE TIME FROM INITIAL REPORT OR DETECTION OF CIRCUIT IMPAIRMENT WILL BE 30 MINUTES AND THE MEAN RESTORE TIME TO REPAIR (MTTR) MUST BE 240 MINUTES. 8. CIRCUIT MUST AVOID SATELLITE LINKS. 9. CONTRACTOR MUST CONTACT THE BELOW LISTED POC AT LEAST 2 WEEKS PRIOR TO INSTALLATION, ACCESS WILL NOT BE GRANTED WITHOUT THE 2 WEEK PRIOR APPROVAL, TECHS WILL BE TURNED AWAY WITHOUT THE APPROVAL 10. JURISDICTIONAL CLASS: INTERSTATE USE, 100 PERCENT ***NOTE: THE CONTRACTOR MUST PROVIDE TSR, CCSD OR CSA IN ALL CORRESPONDENCE INCLUDING WHEN DELIVERING CIRCUIT TO SITE POC*** TECHNICAL ACCEPTABILITY EVALUATION CRITERIA: A QUOTE MUST COMPLY WITH ALL STANDARD PROVISIONS, PROVISIONS, CLAUSES, AND ADDRESS SECTIONS F-M OF THE SOLICITATION TO BE DEEMED TECHNICALLY ACCEPTABLE. ALL PORTIONS OF THE SOLICITATION SHOULD BE CAREFULLY REVIEWED FOR ALL MANDATED REQUIREMENTS OUTLINED WITHIN THE STANDARD PROVISIONS AND DOCUMENTATION REQUESTED AS FOUND IN SECTION M AND AFFILIATED ATTACHMENTS. QUOTATIONS MUST INCLUDE ALL REQUIRED DOCUMENTS AND RESPONSES INDICATED FROM THESE STANDARD PROVISIONS, PROVISIONS, CLAUSES, SECTION M, AND AFFILIATED ATTACHMENTS TO BE CONSIDERED TECHNICALLY ACCEPTABLE AND/OR ELIGIBLE FOR AWARD. IN RESPONSE TO THIS IQO SOLICITATION, NO TERMS, CONDITIONS, OR ASSUMPTIONS WILL BE ENTERTAINED. IF TERMS, CONDITIONS, AND/OR ASSUMPTIONS ARE INCLUDED IN A QUOTATION, THE QUOTATION MAY BE EXCLUDED ON GROUNDS THAT IT FAILED TO COMPLY WITH THE IQO SOLICITATION INSTRUCTIONS. EVALUATION CRITERIA: IN ADDITION TO THE PROCEDURES OUTLINED IN STANDARD PROVISION 23, TECHNICAL EVALUATION TEAM MEMBERS WILL INCLUDE GOVERNMENT PERSONNEL AND MAY INCLUDE GOVERNMENT'S CONTRACTED ADVISORS. GOVERNMENT PERSONNEL WILL MAKE THE FINAL DETERMINATION OF TECHNICAL ACCEPTABILITY. IF THERE ARE QUESTIONS REGARDING SITE SURVEYS OR SITE INFORMATION PLEASE CONTACT THE CONTRACT SPECIALIST LISTED ON THIS SOLICITATION PRIOR TO THE QUOTE DUE DATE.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/9c761f1b4a57468293ec07293d00685c/view)
- Record
- SN06405319-F 20220730/220728230110 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |