SOLICITATION NOTICE
66 -- MULTIGEN2, CO, (VA-22-00055385) 589-22-2-7311-0156
- Notice Date
- 7/28/2022 10:54:04 AM
- Notice Type
- Presolicitation
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- 255-NETWORK CONTRACT OFFICE 15 (36C255) LEAVENWORTH KS 66048 USA
- ZIP Code
- 66048
- Solicitation Number
- 36C25522Q0449
- Response Due
- 8/10/2022 9:00:00 AM
- Archive Date
- 09/24/2022
- Point of Contact
- Buchanan, Lisa A, Contracting Officer, Phone: 913-946-1990
- E-Mail Address
-
lisa.buchanan1@va.gov
(lisa.buchanan1@va.gov)
- Small Business Set-Aside
- SDVOSBC Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- Awardee
- null
- Description
- Statement of Work Stryker Interventional Spine RF MultiGen Generator The Harry Truman VA in Columbia, MO requires a new Stryker Interventional Spine RF MultiGen Generator to be used in treatment of patients with chronic pain. The system requirements are: The ablation system should be designed for radiofrequency procedures to include, but not limited to: Radiofrequency Ablation, DREZ, Facet Denervation, Percutaneous Chordotomy, Peripheral Neuralgia, Rhizotomy and Trigeminal Neuralgia Must have capability to handle multiple lesions simultaneously Must have capability to perform monopolar and bipolar procedures Must have capability to accommodate thermal and pulsed procedures Must have capability to deliver controlled lesions Must have capability to provide multiple pulse settings Must have capability to provide high temperature pulsed radiofrequency Minimum of 100 watts Must be portable Touch screen Allow users to save procedure specific settings for multiple providers Must have the ability to create a large lesion acceptable for genicular and sacroiliac joint regions without increased cost of capital. Must have the ability to create a Venom lesion by deploying electrode outside of cannula to create a V for larger lesion surface area. Must have the ability to use 18 and 20 gauge Venom RF needles. Must have 1 RF Generator Must have 1 splitter cable Must have 1 monopolar return electrode cable Require 8, 100MM Nitinol Electrodes Require 4, 150MM Nitinol Electrodes Must include 12 sterilization boxes for processing Must include 3 identification tags for the sterilization boxes
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/570274899dae472f9c9167e420b0691c/view)
- Place of Performance
- Address: Department of Veterans Affairs Harry S Truman Columbia VAMC 800 Hospital Drive, Columbia 65201
- Zip Code: 65201
- Zip Code: 65201
- Record
- SN06406528-F 20220730/220728230119 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |