SOURCES SOUGHT
65 -- SURGICAL TABLE VA LONG BEACH
- Notice Date
- 8/3/2022 3:25:06 PM
- Notice Type
- Sources Sought
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- 262-NETWORK CONTRACT OFFICE 22 (36C262) Gilbert AZ 85297 USA
- ZIP Code
- 85297
- Solicitation Number
- 36C26222Q1448
- Response Due
- 8/10/2022 4:00:00 PM
- Archive Date
- 10/09/2022
- Point of Contact
- ADRIANA.GARCIA@VA.GOV, ADRIANA GARCIA, Phone: 562-766-2227
- E-Mail Address
-
adriana.garcia@va.gov
(adriana.garcia@va.gov)
- Awardee
- null
- Description
- This is a source sought synopsis only. The purpose of this synopsis is to gain knowledge of potential qualified sources and their size classification (hubzone, 8(a), small, small disadvantage, small veteran owned business or service disabled veteran owned small business) relative to NACIS 339112 (size standard of 750 employees). Responses to this synopsis will be used by the Government to make appropriate acquisition decisions. After review of the responses to this sources sought synopsis, a solicitation announcement may be published in the SAM.gov website. Responses to this sources sought synopsis are not considered adequate responses to the solicitation announcement. All interested offerors will have to respond to the solicitation announcement in addition to responding to this sources sought announcement. The Department of Veterans Affairs, Network Contracting Office NCO22, is seeking sources for a SURGICAL TABLE FOR THE VA LONG BEACH HEALTHCARE SYSTEM. The anticipated award date shall be If you are interested and are capable of providing the required supplies please provide the requested information as indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions: (1) Is your business small (2) If small, does your firm qualify as a small, emerging business, or small disadvantaged business? (3) If disadvantaged, specify under which disadvantaged group and if your firm is certified under Section 8(a) of the Small Business Act? (4) Is your firm a certified Hubzone firm? (5) Is your firm a woman-owned or operated business? (6) Is your firm a certified Service-Disabled Veteran Owned Small Business, (7) Is your firm a Veteran Owned Small Business? Small businesses considering participation in this potential solicitation process under any Small Business Set-aside procedure must do so in a manner consistent with the requirements of the Small Business Act. Responses to this notice shall be e-mailed to Adriana.garcia@va.gov. Telephone responses will not be accepted. Responses must be received in writing no later than 4:00 PM 08/10/22. This notice is to assist the VA in determining sources only. A solicitation is not currently available. If a solicitation is issued it will be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this announcement. Responses to this sources sought is not a request to be added to a prospective bidders list or to receive a copy of the solicitation. Item # Description/Part Number* Qty 1 Steris 4095 Table Bat/Line 120V Ss Fwls W/Tlt Pads / ST013911002 2 2 Inspect and Start-Up 4085 Table / SE1101100072 2 3 Standard Accessory Package with 3"" Anesthesia Armboard Pad w Standard Length Restraint Strap / BF413 2 4 X-Ray Tops Comp Set Snap-in-Style (Cmax, 4085, 5085, 5085 SRT) / BF101 2 5 Bariatric Table Ext Kit W/ 4"" Pads / BF644 1 6 Bariatric Accessory Storage Cart / BF551 1 7 EYE-ENT-NEURO Headrest Adapter (4085,5085) / BF173 2 8 Adult Arm and Hand Table / BF435 1 9 Clark Sockets (Pair) / BF083 1 Salient Characteristics Steris 4085 Surgical Table Must have radiolucent tabletop and Superb C-arm access Must have Centered IA Coverage: imagine length 34 to head and 34 to foot, total imaging ares 518 sq in to head and 514 sq. in to foot. Upper Body IA Coverage: imaging length 43 Must have hand control and Auto Limit Sensor Must Electro-Hydraulic 4-section tabletop w powered radiolucent kidney elevator Must be ergonomically crafted and compact base Must removable leg section Must have Easy to read indication for battery level status Must have 26 to 45 of height range Maximum patient weight support is 1,100 lb. including raise and lower (centered on the column), 1000 lb. full table articulation (centered on the column) and 600 lb. full table articulation including slide Mush have self-leveling floor locks to compensate for uneven O.R floors Must have Integrated manual override system for emergency backup. Must have the following positioning options: Trendelenburg/Reverse 30/30 degrees, Lateral Tilf (left /right) 20 / 20 degrees, Head section +90 / -90 degrees, Back section =80/-40 degrees, flex/reflex 140 / 100 degrees
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/95f24637d4674c379da68b8348d17a4f/view)
- Place of Performance
- Address: DEPARTMENT OF VA LONG BEACH HEALTHCARE SYSTEM 5901 E. 7TH STREET LONG BEACH, 90822
- Record
- SN06413553-F 20220805/220803230119 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |