Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF AUGUST 06, 2022 SAM #7554
SOLICITATION NOTICE

66 -- Low Vibration Cryostat

Notice Date
8/4/2022 5:53:33 PM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
DEPT OF COMMERCE NIST GAITHERSBURG MD 20899 USA
 
ZIP Code
20899
 
Solicitation Number
NB687090-22-01963
 
Response Due
8/15/2022 9:00:00 AM
 
Archive Date
08/30/2022
 
Point of Contact
Patricia Rose, Phone: 3034973106, Angela Hitt, Phone: 3034977305
 
E-Mail Address
patricia.rose@nist.gov, angela.hitt@nist.gov
(patricia.rose@nist.gov, angela.hitt@nist.gov)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
AMENDMENT 1: The purpose of Amendment 1 is to provide an extension to the quotation due date to August 15, 2022 as provided in this posting and provide Questions and Answers as follows: Q1. Is an optical table required as part of this bid? Or will it mount onto an existing optical table? A1. No an optical table is not required, it will mount onto an existing table. Q2. Is any optical access required? Wither windows or Optical fibres? A2. Optical access is required, windows are preferred. Q3. Is there any dimensions available for the HTS leads? A3. Approximately 5mm wide HTS ribbon or arbitrary length. Q4. How will the vibrations be tested? By LASER interferometer or by experiment? Are there any frequencies that are particularly critical for damping? A4. Laser interferometry. Q5. Is a support frame over the optical table preferred or a a cryostat that mounts from underneath the optical table? A5. A cryostat that mounts from underneath is preferred. Q6. Is there a preference for the coax cable to be used? UT85 SS/SS, UT47 BeCu, UT47 CuNi for example? A6. SS/SS or BeCu are ok, UT47 is preferred, CuNi is not acceptable. Q7. Is mounting required for the positioners? If so then is data available for the size / mounting holes? A7. Mounting holes will be required, detailed specifications are flexible and can be supplied later. Q8. Is an inverted sample space acceptable? Or a platform that hangs below the cryostat? A8. Non-inverted sample space is preferred. Q9. Is a higher cooling power useful? >130mW @ 4.2K A9. Higher cooling power is useful. Q10. Is a lower base temperature (I.E < 1.8K) useful? A10. A lower base temperature is useful. NO OTHER CHANGES ________________________________________________________________________________________________________ Please see the attached RFQ and associated documents to respond to this RFQ.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/3aaba07d2934457a8b59f2727565f9b5/view)
 
Record
SN06415085-F 20220806/220804230114 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.