SOLICITATION NOTICE
66 -- Low Vibration Cryostat
- Notice Date
- 8/4/2022 5:53:33 PM
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- DEPT OF COMMERCE NIST GAITHERSBURG MD 20899 USA
- ZIP Code
- 20899
- Solicitation Number
- NB687090-22-01963
- Response Due
- 8/15/2022 9:00:00 AM
- Archive Date
- 08/30/2022
- Point of Contact
- Patricia Rose, Phone: 3034973106, Angela Hitt, Phone: 3034977305
- E-Mail Address
-
patricia.rose@nist.gov, angela.hitt@nist.gov
(patricia.rose@nist.gov, angela.hitt@nist.gov)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Description
- AMENDMENT 1: The purpose of Amendment 1 is to provide an extension to the quotation due date to August 15, 2022 as provided in this posting and provide Questions and Answers as follows: Q1. Is an optical table required as part of this bid? Or will it mount onto an existing optical table? A1. No an optical table is not required, it will mount onto an existing table. Q2. Is any optical access required? Wither windows or Optical fibres? A2. Optical access is required, windows are preferred. Q3. Is there any dimensions available for the HTS leads? A3. Approximately 5mm wide HTS ribbon or arbitrary length. Q4. How will the vibrations be tested? By LASER interferometer or by experiment? Are there any frequencies that are particularly critical for damping? A4. Laser interferometry. Q5. Is a support frame over the optical table preferred or a a cryostat that mounts from underneath the optical table? A5. A cryostat that mounts from underneath is preferred. Q6. Is there a preference for the coax cable to be used? UT85 SS/SS, UT47 BeCu, UT47 CuNi for example? A6. SS/SS or BeCu are ok, UT47 is preferred, CuNi is not acceptable. Q7. Is mounting required for the positioners? If so then is data available for the size / mounting holes? A7. Mounting holes will be required, detailed specifications are flexible and can be supplied later. Q8. Is an inverted sample space acceptable? Or a platform that hangs below the cryostat? A8. Non-inverted sample space is preferred. Q9. Is a higher cooling power useful? >130mW @ 4.2K A9. Higher cooling power is useful. Q10. Is a lower base temperature (I.E < 1.8K) useful? A10. A lower base temperature is useful. NO OTHER CHANGES ________________________________________________________________________________________________________ Please see the attached RFQ and associated documents to respond to this RFQ.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/3aaba07d2934457a8b59f2727565f9b5/view)
- Record
- SN06415085-F 20220806/220804230114 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |