SOURCES SOUGHT
65 -- Welch Allyn Connex System
- Notice Date
- 8/5/2022 1:14:10 PM
- Notice Type
- Sources Sought
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- 261-NETWORK CONTRACT OFFICE 21 (36C261) MATHER CA 95655 USA
- ZIP Code
- 95655
- Solicitation Number
- 36C26122Q0964
- Response Due
- 8/12/2022 12:00:00 PM
- Archive Date
- 08/22/2022
- Point of Contact
- Mandy Thompson, Contract Specialist, Phone: 650-493-5000 x62211
- E-Mail Address
-
mandy.thompson2@va.gov
(mandy.thompson2@va.gov)
- Awardee
- null
- Description
- Page 3 of 3 This is a Sources Sought only. The Department of Veterans Affairs (VA) Network Contracting Office (NCO) 21 is performing market research to determine if there are any vendors with economic status of Service-Disabled Veteran Owned, Veteran Owned, Women Owned, and other Small Businesses that can provide the Welch Allyn Connex System. Responses to this Sources Sought will be used for market research purposes. This requirement is for the Veterans Integrated Service Network (VISN 21) procurement to provide the Welch Allyn Connex System. There is no solicitation document as this time. The NAICS is 339112 with Small Business size of 1000 employees. NOTE: Please ensure that System For Award Management (SAM) (www.sam.gov) indicates this NAICS code if you are interested in the requirement. If you are responding as an SD/VOSB vendor, you must be verified on the Vendor Information Pages (VIP) at https://www.vip.vetbiz.gov/ AND your verification must indicate this NAICS code. Only firms interested and capable should send their information and/or capability statement and any questions by email to mandy.thompson2@va.gov no later than 12:00 PM Pacific Standard Time, August 12, 2022. If interested, please provide the following information: Name of Company Point of Contact Name, phone number, and email address SAMS Unique Entity ID Number Socio-economic status such as Service-Disabled Veteran Owned Small Business, VOSB, Women-Owned Small Business, etc. should be included. SDVOSB/VOSB status and NAICS will be verified using VIP. Capability statement(s) Authorized Distributor Memo on Manufacturers letterhead Indicate if any other relevant information DISCLAIMER This Sources Sought notice is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this request that is marked proprietary will be handled accordingly. The Government will not compensate an offeror for providing information in response to this sources sought. Furthermore, the Government reserves the right to cancel this requirement at its discretion. This is simply a source sought notice. See below draft salients and contract line-item numbers. Brand Name Item: Welch Allyn Connex 6800, Connex Server, and Connectivity License Essential/significant physical, functional, or performance characteristics Overall solution must be compatible with receiving ADT (Admit/Discharge/Tranfer) data from VistA or Cerner Electronic Health Records. Server can be installed as a Virtual Machine and must utilize a currently supported Operating System, such as Windows Server 2019. Server should allow for being added to the VA domain. Both a test server and production server instance shall be provided. Each vital sign machine must be able to transmit vitals data to the main server through either a hard wired or wireless configuration. Wireless network card must be FIPS 140-2 certified and use specific pre-shared key for authentication with the system. Hardwired network system must allow for a minimum 100mbs auto authentication with the network switches. Each vital sign machine must be able to measure SpO2, temperature, Non-invasive Blood pressure, Pulse Rate, and allow for manual entry of other values such as respiratory rate, or pain measurement scoring. SpO2 technology must be Masimo. Each vital sign must have a barcode scanner to scan patient wrist band/ID, and staff badge. Complete generic identification Vital Sign Monitor and Connectivity to EHR Applicable model/make/catalog number Welch Allyn Connex 6800, Connex Server Manufacturer name Hillrom/Welch Allyn ITEM NUMBER DESCRIPTION OF SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0001 1.00 EA __________________ __________________ IR HTM 003 23d- NCHCS Welch Allyn Connex System - VISN21- 22REQ2037d 2022-OIT-EHRM-145247-Infra-N/A 2022-OEHRM-273-5 Mather, CA License 106900 Connex Server Application (Prod/Test) 0002 74.00 EA __________________ __________________ Mather, CA License 1000981 Welch Allyn Device Connectivity License 0003 74.00 EA __________________ __________________ Mather, CA Equipment 68MXTX-B Welch Allyn Connex 6800 Vital Sign 0004 74.00 EA __________________ __________________ Mather, CA Equipment 6000-916HS Welch Allyn HS-1M 2D Barcode Scanner 0005 60.00 EA __________________ __________________ Mather, CA Equipment 008-0834-01 GCX Wall Mount Kit for Welch Allyn VSM 0006 14.00 EA __________________ __________________ Mather, CA Equipment 4800-60 Welch Allyn Accessory Cable/Mobile Stand 0007 1.00 EA __________________ __________________ Mather, CA Support S3-PREMIUM-CS Software Support 0008 1.00 EA __________________ __________________ Mather, CA Installation INS-PS-01 Installation 0009 74.00 EA __________________ __________________ Mather, CA Delivery DELIVERYASSIST
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/93a7a85eee334de79ffc5b5efae7dd3d/view)
- Record
- SN06416837-F 20220807/220805230123 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |