SOLICITATION NOTICE
N -- Switchgear Metering and Preventative Maintenance Project
- Notice Date
- 8/10/2022 7:59:26 AM
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 238210
— Electrical Contractors and Other Wiring Installation Contractors
- Contracting Office
- SAC FREDERICK (36C10X) FREDERICK MD 21703 USA
- ZIP Code
- 21703
- Solicitation Number
- 36C10X22Q0225
- Response Due
- 8/30/2022 7:00:00 AM
- Archive Date
- 09/14/2022
- Point of Contact
- Justin Cole / Tanya Sims-Williams, Justin Cole
- E-Mail Address
-
Tanya.Sims-Williams@va.gov, Justin.Cole4@va.gov
(Tanya.Sims-Williams@va.gov, Justin.Cole4@va.gov)
- Description
- The Contractor shall be responsible to inspect, test, document deficiencies, repair/refurbish, retest, paint, tag, package and reship/reinstall switchgear breakers at HITC. The Contractor shall provide all necessary labor, tools, material, parts, testing equipment, supervision to service switchgear breakers while maintaining energized circuits/no power disruptions to the data center operation. The overall goal of the project is to upgrade the static trips units on the data center related switchgear breakers, perform preventative maintenance on all facility (house) and data center breakers to ensure compliance with NFPA/NEC 70E. The Contractor shall: Purchase and install eleven (11) of the Utility Relay Company�s AC PRO II (or equal) static trip units, broken down as follows: -� Five (5) DS-206 switchgear breakers with 120v controls (currently installed and operational). -� Six (6) bench stock DS-206 switchgear breakers (refurbished/benchstock). -� Purchase and install a Monitoring and Control System that is compatible to the static trip units that display, monitor, and log power consumption (Amps/Voltage/KVA) of each breaker and cumulative of the entire system. One unit will be Wi-Fi and internet compatible to the VA system where the user can access it from any VA device. The other unit will be a control device at the system of operation.� HMI will be in the switchgear room and also via the web base interface. HITC�s existing switch gear breakers are all custom fabricated Square D or Siemens breakers to fit in the Westinghouse frames. The Contractor shall provide a turn-key solution with refurbishing the existing breakers.� The reconditioned breakers shall be altered from the existing switchgear frame or settings, which are Westinghouse brand (Eaton). The model numbers are unknown. The vendor shall provide the brand name product listed above, or an �equal� product that meets the following known electrical gears: Siemens, DS-623-Type 3200A-Frame Siemens, DS-416-Type 1600A-Frame 1600A Siemens, DS-206-Type 800A-Frame 800A
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/ee10656b9e6041bca8e2df9611311044/view)
- Place of Performance
- Address: Hines, IL 60141, USA
- Zip Code: 60141
- Country: USA
- Zip Code: 60141
- Record
- SN06421101-F 20220812/220810230117 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |