Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF SEPTEMBER 10, 2022 SAM #7589
SOURCES SOUGHT

65 -- Hematology Analyzers Naval Hospital Yokosuka

Notice Date
9/8/2022 7:03:43 AM
 
Notice Type
Sources Sought
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
DEFENSE HEALTH AGENCY FALLS CHURCH VA 22042 USA
 
ZIP Code
22042
 
Solicitation Number
HT941022N0010
 
Response Due
9/23/2022 8:00:00 AM
 
Point of Contact
Cassi Jo Newman, Phone: 7262030088, Jeff Collins, Phone: 7262030106
 
E-Mail Address
cassi.j.newman.civ@health.mil, jeffrey.p.collins20.civ@health.mil
(cassi.j.newman.civ@health.mil, jeffrey.p.collins20.civ@health.mil)
 
Description
The Defense Health Agency intends to negotiate on a sole source basis (IAW FAR 13.501(a), Only One Responsible Source. The proposed source is Beckman Coulter Life Sciences Japan, 3-5-7 Ariake Koto-Ku, Tokyo, Japan 135-0063. Hematology analyzers are required to attain the standard for production for Naval Hospital Yokosuka Japan and Branch Health Clinics located in Atsugi, Sadebo, and Iwakuni, Japan and Diego Garcia, United Kingdom. �Hematology benches are workstations used to conduct Complete Blood Counts and other hematology testing methods. �Without in-house analyzers, the blood samples would have to be shipped to laboratories in Japan or the United States. �Blood samples cannot be frozen for transport and must be analyzed within 48 hours to ensure the integrity of the sample and the test results. �Samples from remote locations like Diego Garcia will take approximately 1 week to ship to laboratories in Japan resulting in a 2-week turnaround for critical and potentially life-saving test results and diagnosis. �One potentially viable option is to send samples to local laboratories in Japan; however, utilization of these laboratories presents a greater risk of clerical errors due to language barriers in addition to additional turnaround time, the risk of reliable transport of samples between sites, and sample deterioration which can lead to adverse patient outcomes in emergency situations. The seven (7) hematology analyzers, to be delivered, installed, and validated no later than 1 January 2023 meeting the following minimum requirements: Must have a Laboratory Information System (LIS) and ethernet connection Must have date storage: �30,000 patient results including graphics, flags, codes and messages Must have 12 control files each with a maximum of 150 runs Must perform roughly 1,000 test per month within 48 hours of blood draw to include 17 uL of venous or micro-collected whole blood and 20 uL of hole blood for pre-diluted analysis Must provide results for the following Complete Blood Count parameters: �white blood cell, red blood cell, hemoglobin, hematocrit, mean corpuscular volume, mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration red cell distribution width-standard deviation, platelet, mean platelet volume, reticulocytes, absolute reticulocytes, mean reticulocyte volume, immature reticulocyte fraction Must provide the following differentials: �neutrophils, lymphocytes, monocytes, eosinophils, basophils, monocyte volume width distribution, nucleated red blood cell, absolute neutrophils, absolute lymphocytes, absolute monocytes, absolute eosinophils, absolute basophils, absolute nucleated red blood cell Must perform the following body fluids (CSF, serous and synovial): �total nucleated cell count, red blood cell, @BFM%, @BFP% Must be able to use USB printer Must have touch screen display and handheld barcode scanner Local maintenance and repair support for the 4 geographic locations within 12 hours of notification, including weekends and holidays. Manufacturer must offer on-site training, in English, for two (2) technicians in Japan and a separate training for the Branch Clinic located in Diego Garcia in conjunction with installation Due to the configuration of the laboratories, the following size and electrical limitations must be met: Analyzer 1 (Diego Garcia) (Qty 2): H: 406mm, W: 270mm, D: 430mm; Weight: 25.1lbs Electrical Power Supply: �VAC 100-240, Hz 50-60, three-wire AC outlet, Single Phase Analyzer 2 (Qty 5): H: 82.42cm, W: 75.57cm, D: 82.80cm; Weight: 560 lbs Electrical Power Supply: �VAC 90-264, Hz 48-63, three-wire AC outlet, Single Phase Critical Values Feature: Enables onscreen and printed notification of critical hematology results to enable easy identification and accelerated reporting of critical values. �User-defined critical values and customized notification text add flexibility needed to support the differences in notification policies from one facility to another. Delivery Dates Base:� 30 September 2024 OPT1:� 30 September 2025 OPT 2:� 30 September 2026 OPT 3:� 30 September 2027 OPT 4:� 30 September 2028 There are not set-aside restrictions for this requirement.� The intended procurement will be classified under North America Industry Classification System (NAICS) 334516.� This notice of intent is not a request for competitive proposals and no solicitation document exists for this requirement.� However, parties interested in responding to this notice will need to submit technical data sufficient to determine capability in providing the same product.� All capability statements received by the closing date of this synopsis will be considered by the Government.� A determination by the Government not to compete based on responses to this notice is solely within the discretion of the Government.� Information received will be considered solely for the purpose of determining whether to conduct a competitive procurement. If a vendor challenges the basis of this requirement, please email product capability statements (formats for submission: PDF, MS Word, or MS Excel) to Cassi Jo Newman at cassi.j.newman.civ@health.mil Closing date for challenges is no later than 0800 PST on 23 September 2022.� No phone calls will be accepted.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/174cdb6d806445e0a74cec9a9ee6a68b/view)
 
Place of Performance
Address: YOKOSUKA, JPN
Country: JPN
 
Record
SN06458439-F 20220910/220908230133 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.