Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF OCTOBER 09, 2022 SAM #7618
SOURCES SOUGHT

C -- 518-21-110 Steam Replacement and Distribution

Notice Date
10/7/2022 10:19:23 AM
 
Notice Type
Sources Sought
 
NAICS
541330 — Engineering Services
 
Contracting Office
241-NETWORK CONTRACT OFFICE 01 (36C241) TOGUS ME 04330 USA
 
ZIP Code
04330
 
Solicitation Number
36C24122Q0614
 
Response Due
11/9/2022 1:00:00 PM
 
Archive Date
01/09/2023
 
Point of Contact
Sary Nhet, Contract Specialist, Phone: Email only, please
 
E-Mail Address
sary.nhet@va.gov
(sary.nhet@va.gov)
 
Small Business Set-Aside
SDVOSBC Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
 
Awardee
null
 
Description
SOURCES SOUGHT: The Bedford VA Medical Center located at 200 Springs Road in Bedford, MA has a requirement for a Firm Fixed Price contract to provide professional Architect/Engineer (A/E) Design for Project Number 518-21-110 Steam Replacement and Distribution. The objective of this scope of work is an A/E design package (drawings and specifications) consisting of a thorough review of the current Energy Distribution System (EDS), an overall energy and efficiency audits of the entire EDS, a minimum of 2 alternative upgrades scenarios for the EDS, and construction drawings and cost estimates to implement each scenario. SCOPE: The scope of this project consists of Architectural and Engineer (A/E) services required to complete the project. The period of performance (type A and B services) is 250 calendar days, beginning with the issuance of the Notice to Proceed (NTP) by the Contracting Officer to the acceptance of 95% Construction Document. The Magnitude of Construction is between $2,000,000 to $5,000,000. The VA will not be responsible for any costs incurred by interested parties in responding to this announcement. This is a Request for Qualifications: The purpose of this notice is to request SF-330 Qualification statements from qualified SDVOSBs that have the experience directed at the requirements of the Statement of work. The design effort is to be completed by more than 50% SDVOSB. The NAICS code is 541330 and the small business size standard is $22.5 million. Firms must have valid registration in the System for Award Management (SAM). Visit: SAM.gov to register in this database. SDVOSB firms must be verified in VETBIZ under NAICS 541330. Visit: vip.vetbiz.va.gov RESPONSE: Interested SDVOSB firms must provide their qualifications to the Contracting Specialist no later than 10:00am on 07/08/2022 via email to Sary.Nhet@va.gov The following information is required as a valid response: A positive statement of your intention to submit a proposal in response to a solicitation for this project and include your firm s UEI Number, Firms address and Contact information. Evidence of your experience in A/E Services for complete design and construction of a project similar to this one, preferably with the VA and/or Medical facility (please provide contract descriptions, contract dollar amounts and telephone numbers for points of contact no photographs). Qualifications (Adjectival Evaluation Factors): Facility Energy Efficiency Design and/or Energy Distribution System Design (minimum 3 projects in 10 years) Past Performance (minimum no more than 1 marginal noting in CPARS in the last 3 years) Competency of staff in disciplines (civil engineering projects, minimum of 3 medium [> 2M+/- construction budget] experience in last 10 years) Location proximity to Bedford VAMC (200 miles or less) SF-330 Architect- Engineer Qualifications completed for the intent of the project. Evidence that your SDVOSB firm will perform more than 50% of the requirement with a qualified SDVOSB and or VOSB team. Failure to submit all information requested will result in a contractor not being considered as an interested SDVOSB concern. EVALUATION FACTORS: Adjectival Description Exceptional A comprehensive and thorough presentation of extraordinary merit with one or more significant strengths. Offeror s response is clearly superior. The response is innovative and exceeds requirements. No deficiency or significant weaknesses exists. Good Exceeds all the minimum requirements of the criteria; has an above average probability of success; contains no significant weaknesses and only minor, correctable weaknesses exist. Acceptable Meets all the minimum requirements of the criteria; has an average probability of success; no significant weaknesses and any deficiencies can be readily corrected. Marginal Fails to meet one or more of the minimum requirements of the criteria; low probability of success; major weaknesses and/or significant number of deficiencies exist. Unacceptable Fails to meet any of the minimum requirements of the criteria; very low probability of success. Neutral (Applies only to Past Performance) Offeror s performance record, relevant past performance or information on past performance is not available SELECTION PROCESS: The A/E selection will be completed in two stages as follows: In Stage I, interested firms will submit SF-330 Qualification Statements of Capabilities. In Stage II, the A/E team most qualified will be requested to submit a price proposal for negotiations in an issued Request for Proposal. PROJECT INFORMATION ATTACHMENT: Attachment 1 - Project Design Schedule (to be developed) Attachment 2 - Survey & Web-Geographic Information Services. Project Number 518-12-04, Drawings 1-14, May 17, 2013. Attachment 3 - Facility Master Plan, pages 1-48 for existing facility overview, dated 12/31/2012, by HAI Architecture Attachment 4 - Steam Distribution Drawings: (1) Original Steam Distribution Layout. Drawings 1-13, Dated 1/15/1927. (for reference only). (2) Steam Distribution Alterations to Bldgs #2 & 22. Project Number 20-5220, Drawings 1-13, dated 11/26/1958. (3) Replacement Steam Distribution Project Phase II, Project Number 518-81-140, 11 Drawings 1-11, dated 12/7/1990. Attachment 5 - Upgrade Steam Distribution System Phase I, Project Number 518-96-110, Drawings 1-36, dated 11/30/1998. Attachment 6 - Upgrade Steam Distribution System Phase II, Project Number 518-96-110, Drawings 1-28, dated 11/30/1998. Attachment 7 - VA-Upgrade Steam Distribution Phase III, Project 518-07801-ES, Drawings 1-15, dated 12-04-2009. Attachment 8 - Alterations to Buildings #2, 4, & 22 and Steam Distribution, Project Number 20-5220, Drawings 1-20, dated 11/26/1958. Attachment 9 - Repair Stacks & Steam Lines - Project Number W912DR-09-D-D-0014, Drawings 1-20, dated 08/18/2009 Attachment 10 - Standard Plumbing Sheets, Drawings 1-12, dated 11/10/2013-07/13/1945. Attachment 11 - Steam Condensate Return System, Project Number 518-80-215, Drawings 1-8, dated 6/15/1987. Attachment 12 - Electrical Panel and Feeder Diagrams for Facility: (1) Updated High Voltage Electrical One-Line Schematic Diagrams, Project Number 2523-102, drawings E701-E706, dated 6/21/2017. (2) Electrical Distribution System Upgrades, Project Number 518-13-104, drawings 1-36, dated 2/16/2018. Attachment 13 - Boiler #3 Replacement: (1) Replace Boiler #3 - Bldg #22, Project # 518-04-106, Drawings 1-11, dated 4/21/2006. (2) Boiler #3 Replacement Project Pipe Connections As-Built Drawings - Dillon Boiler Services, Drawings 12465-12468, dated 11/03/2010 Attachment 14 - Replace Blrs #1 & #2 Project Number 518-96-101, Drawings 1-25, dated original construction 07/30/97 and as-built drawings 08/17/1997 Attachment 15 - Boiler Plant Safety Improvements Bldg #22. Project Number 518-10-102, Drawings 1-11, dated 7/16/2010. Attachment 16 - Steam, Heating Hot Water, and Outside Distribution Systems Design Manual, September 2016, Volume 1 Steam Boilers. Attachment 17 - Boiler Plant Piping System Specifications, Section 23.21.11, dated 02/01/2020. Subset of Design Manuals (PG-18-10); HVAC Design Manual for New, Replacement, Addition and Renovation of Existing VA Facilities: Department of Veterans Affairs, Office of Construction and Facilities Management. Attachment 18 - Outside Steam, Heating Hot Water, and Distribution Design Manual, November 1, 2020. Attachment 19 - Steam and Condensate Heating and Piping Specification, Section 23.22.13, dated 02/01/2020. Attachment 20 - Steam condensate pumps for Heating, Ventilating & Air Conditioning Specification, Section 23.22.23, dated 04/01/2020 Attachment 21 - Boiler Plant Mechanical Equipment Specification, Section 23.50.11, dated 04/01/2020 Attachment 22 - Steam Energy Distribution Specification, Section 33.63.00, dated 09/01/17 Attachment 23 - HVAC Design Manual, originally written 11/01/2017, revised 03/01/2020. Attachment 24 - Model CBLE Cleaver Brooks 125-800 Hp Package Boiler O&M Manual, Revision 02/2013 Attachment 25 - VHA Supplemental Contract Requirements for Combatting COVID-19 Updated 12-14-2021
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/bb0c1e4d8cf043e29ef8e3710e8f83ee/view)
 
Place of Performance
Address: Bedford VA Medical Center Edith Nourse Rogers Memorial Veterans Hospital 200 Springs Road, Bedford 01730, USA
Zip Code: 01730
Country: USA
 
Record
SN06489892-F 20221009/221007230116 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.