H -- 3RD PARTY BOILER INSPECTION SERVICE BASE + 4 OYS

Notice Date
10/11/2022 5:07:23 AM
 
Notice Type
Solicitation
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
252-NETWORK CONTRACT OFFICE 12 (36C252) MILWAUKEE WI 53214 USA
 
ZIP Code
53214
 
Solicitation Number
36C25223Q0002
 
Response Due
10/17/2022 8:00:00 AM
 
Archive Date
11/16/2022
 
Point of Contact
Susan Pasholk, CONTRACT SPECIALIST
 
E-Mail Address
susan.pasholk@va.gov
(susan.pasholk@va.gov)
 
Awardee
null
 
Description
Is this for one Testing/Tuning visit per year or two per year as specified in VHA 1810?This contract is to have a 3rd party test all the safety devices in the Steam plant as directed by VA directive 1810 And provide documentation of the findings. Per 1810, this is the definition of a qualified test contractor- Qualified Testing Contractor. A qualified testing contractor is an individual/company that has performed testing in compliance with VHA Boiler and Associated Plant Safety Device Testing Manual in at least three other VA medical facilities. Please provide Make and Models for all 3 boilers, DA Tank & Condensate Tank Boiler #1 is a Simoneau- Sterling Serial #5385 20,000 lbs per hour, Boiler #2 is Simoneau -Sterling  Serial # 5384 30,000 lbs per hour and Boiler 3 is just like boiler 2 but has serial # 5383. The DA tank Is a Simoneau tank with a max working pressure of 50 PSI at 350 degrees Serial # 5399 and the condensate tank  has a max working pressure of 50 psi at 298 degrees serial # 5401 Is National Board Inspections included in this contract? If so: NO, This is not an internal inspection but rather a safety device test Does the VA open & close the boilers for inspection? NA Does the VA provide all gaskets? NA For DA Tank & Condensate Tank, Is the 6 Year NDT inspection included during any of these 5 years? If so, which year (s)? No Is Transmitter Calibration included in this contract? If so, how many transmitters? No, We will be soliciting another contract that will deal with Testing, calibration and burner tuning Is Gauge Calibration included in this contract? If so, how many gauges? No. We will be soliciting another contract that will deal with Testing, calibration and burner tuning
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/67f7e7cdf3e24adda22e97a194636bac/view)
 
Record
SN06490514-F 20221013/221011230056 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.