SPECIAL NOTICE

61 -- 15Kv Electrical Switchgear - construction

Notice Date
11/4/2022 7:31:01 AM
 
Notice Type
Special Notice
 
NAICS
238210 — Electrical Contractors and Other Wiring Installation Contractors
 
Contracting Office
W072 ENDIST DETROIT DETROIT MI 48226-5000 USA
 
ZIP Code
48226-5000
 
Solicitation Number
W911XK-22-JA-Switchgear
 
Response Due
11/14/2022 10:00:00 AM
 
Point of Contact
Teresa Kelly, Phone: 3132267474, Glenn W. Moon
 
E-Mail Address
teresa.l.kelly@usace.army.mil, Glenn.W.Moon@usace.army.mil
(teresa.l.kelly@usace.army.mil, Glenn.W.Moon@usace.army.mil)
 
Description
The United States Army Corps of Engineers (USACE), Detroit District will be soliciting proposals for a construction contract to replacement the 15kV Electrical Switchgear at the Hydropower Plant, Sault Ste Marie, Michigan.� As part of the construction contract solicitation, USACE intends to include the following two (2) sole source requirements: (1) Manufacturer, ABB Inc. � Campus Montreal, is the only authorized source for maintenance, updates, and repair of the static excitation system (aka: exciter), as ABB considers the exciter as specialized proprietary equipment.� The exciter is vital to maintaining availability of the Hydro Units.� The USACE Hydropower plant, located at the Soo Project Office, has been identified as �critical� to facility operations by the Cloverland Electric Company and to the Greater Eastern Upper Peninsula Region of Michigan.� An exciter failure is considered a �critical� failure, and results in the Hydro Generator shutting down.� ABB is the manufacture and installer of the existing static exciter.� It is imperative that only certified engineers/technicians update and test the system.� Unqualified personnel not familiar with this critically sensitive specialized equipment could harm the Hydro Generator by causing permanent damage.� It is anticipated that validating the system will need to be accomplished while the unit is online. The exciter is electronic with numerous set-points and accidentally changing a parameter could result in significant damage to the generator, which would potentially cost the Government hundreds of thousands of dollars in replacement costs.� Additionally, any miss-step with 13,800 VAC could result in personnel injury and electrical damage to the exciter.� (2) Manufacturer, Voith Group - Voith US Inc, is uniquely qualified since they are the manufacture and installer of the governor control system on the hydro generator unit. Voith does not authorize other contractor to install or update their systems. �Updating the governor involves identifying hard to detect issues, parameter adjustment, and calibration of the electronic based system that is unique to Voith�s equipment.� Modifying it requires intimate knowledge and specific skills typical of manufacturer trained personnel.� The governor is vital to maintaining availability of the Hydro Units. The USACE Hydropower plant, located at the Soo Project Office, has been identified as �critical� to facility operations by the Cloverland Electric Company and to the Greater Eastern Upper Peninsula Region of Michigan.� A governor failure is considered a �critical� failure, and results in the Hydro Generator shutting down.� Voith is the manufacture and installer of the existing governor control system.� It is imperative that only certified engineers/technicians update and test the system.� Unqualified personnel not familiar with this critically sensitive specialized equipment could harm the Hydro Generator by causing permanent damage.� It is anticipated that validating the system will need to be accomplished while the unit is online. The governor is electronic with numerous set-points and accidentally changing a parameter could result in significant damage to the generator, which would potentially cost the Government hundreds of thousands of dollars in replacement costs.� All responsible sources may submit a capability statement which shall be considered by the agency.� The submission must be received no later than 1:00 p.m. Eastern time on 14 November 2022 to teresa.l.kelly@usace.army.mil. THIS IS NOT A REQUEST FOR PROPOSAL
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/0e1a14700def40989e5dbf4bbbb0b1da/view)
 
Place of Performance
Address: 0, MI 49783, USA
Zip Code: 49783
Country: USA
 
Record
SN06510097-F 20221106/221104230054 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.