Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF NOVEMBER 06, 2022 SAM #7646
SOURCES SOUGHT

65 -- COVID-19 ANTIGEN TESTING - VISN 15 BASE + 3 Option Years

Notice Date
11/4/2022 5:59:07 AM
 
Notice Type
Sources Sought
 
NAICS
325413 — In-Vitro Diagnostic Substance Manufacturing
 
Contracting Office
255-NETWORK CONTRACT OFFICE 15 (36C255) LEAVENWORTH KS 66048 USA
 
ZIP Code
66048
 
Solicitation Number
36C25523Q0035
 
Response Due
11/10/2022 9:00:00 AM
 
Archive Date
12/25/2022
 
Point of Contact
Shelley Welton, Contract Officer, Phone: Contract Specialist, Fax: Betty Flores - veronica.flores@va.gov
 
E-Mail Address
SHELLEY.WELTON@VA.GOV
(SHELLEY.WELTON@VA.GOV)
 
Awardee
null
 
Description
This is a SOURCES SOUGHT announcement only. It is neither a solicitation announcement nor a request for proposal or quote and does not obligate the Government to award a contract. Responses to this Sources Sought must be in writing. The purpose of this Sources Sought Announcement is for market research, to make appropriate acquisition decisions, and to gain knowledge of potential qualified businesses capable of providing the following: VISN 15 Ancillary Testing: COVID 196 Antigen Testing for the following VA Medical Centers: Harry S. Truman VA Medical Center, 800 Hospital Drive, Columbia, MO 65201 Kansas City VA Medical Center, 4801 East Linwood Blvd, Kansas City, MO 64126 John J. Pershing VA Medical Center, 1500 N. Westwood Blvd, Poplar Bluff, MO 63901 St Louis Medical Center, John Cochran Division, 915 North Grand Blvd, St. Louis, MO 63106 Colmery-O Neil VA Medical Center, 2200 Gage Blvd, Topeka, KS 66622 Robert J. Dole VA Medical Center, 5500 E. Kellogg Avenue, Wichita, KS 67218 Dwight D. Eisenhower VA Medical Center, 4101 S. 4th Street Trafficway, Leavenworth, KS 66048 This requirement is for a Base and Three (3) Option Years *** See Statement of Work below for details *** If this is within your capability, please respond with the information below to both point of contacts below: Company Name Address Point of Contact Phone, Fax, and Email UEI number GSA Contract (as applicable) Interested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications to be considered for award. In addition, FAR 4.11 states that prospective contractors shall be registered in the System for Award Management (www.SAM.gov) database. All Service-Disabled Veteran Owned Small Businesses (SDVOSB) and Veteran Owned Small Businesses (VOSB) shall be verified in VetBiz at www.vip.vetbiz.gov. Point of Contact for this Sources Sought is: Shelley Welton, Shelley.Welton@va.gov Alternate Point of Contact for this Sources Sought is: Betty Flores, Veronica.Flores@va.gov Department of Veterans Affairs Network Contracting Office -15 3450 S. 4th Street Trafficway Leavenworth, KS. 66048.  STATEMENT OF WORK (SOW) FOR VISN 15 Ancillary Testing: COVID 196 Antigen Testing INTENT: It is the intent of the Department of Veterans Affairs, (herein afterwards referred to as VISN 15) to establish an agreement for Point of Care Reagents, Test Kits & Sets for COVID-19 Antigen test and controls. Contractor agrees to the following terms with the VISN facilities listed by Attachment A herein and awarded. However, as requirements change, facilities within VISN 15 may be added or deleted by supplemental agreement of the Government and the Contractor. ORDERS: The Government is obligated only to the extent of authorized orders issued under the agreement by authorized individuals. PRICES AND TERMS: VISN 15 will provide an estimated volume by test as reflected in Attachment B for each individual medical center and outpatient clinic laboratory. Pricing is based on the AVERAGE daily test volume for each facility. The Government estimates the volumes per facility as listed in Attachment B but does not guarantee volumes as listed; they are estimates ONLY. TERM OF agreement: This will be a single vendor award, firm-fixed price agreement with one base year and three, one-year options. This agreement is not a contract. VISN 15 intends to establish the base year of the agreement for the period of 12/01/2022 through 11/30/2026. IDENTIFICATION: Delivery Orders issued shall be identified by their applicable agreement Number. Agreement identification numbers are assigned through the VHA. ORDERING METHOD: The participating facilities in Attachment A may order products via Electronic Data Interchange (EDI), telephone, facsimile, or other written communication, identifying the products by number, quantity, purchase price, address for delivery, and any special instructions. DESCRIPTION/SPECIFICATIONS/STATEMENT OF WORK SCOPE OF PROCUREMENT: Contractor shall provide the following test kits and controls required to perform rapid COVID-19 screening to patients and employees according to the delivery schedule. Item # Description/Part Number* Qty 0001 Covid-19 Ag Test Card (40 test) 964 0002 COVID-19 Ag Self-Test Card (24 per kit) 267 003 COVID-19 Ag Control Kit (10 Positive Strips per kits) 58 Single purchase acquisition with On- Demand delivery schedule. GENERAL REQUIREMENTS Technical Features Test kits must be Clinical Laboratory Improvement Amendments (CLIA) waived. The COVID-19 Ag swab test must be acceptable to use with individuals suspected of COVID-19 in all sections of the hospital, including patients with bleeding disorders, spinal cord injury, traumatic brain injury, and patients undergoing major surgery for head and neck diseases. Testing time should be equal or less than 15 minutes. Test procedure must include minimal pre-treatment steps post collection. Test procedure must include minimal sample manipulation to decrease potentially infectious exposures. Test Kits from the same shipment must have the same lot numbers and expiration date. Packaging and Inspection: All kits will be packaged with adequate materials to ensure safe handling. If a kit is delivered and upon inspection the materials are found to be defected, the contractor shall deliver a new kit immediately upon notification at no additional costs. Quality QC material should be included in every box to meet regulatory standards. QC material should at minimal include a positive control. Additional shipments of the same lot number must include additional QC material. If 3-5% of the kits fail to perform, it will be reported to the contractor and the contractor shall send a replacement test kit at no additional charge. Attachment A: Harry S. Truman VA Medical Center, 800 Hospital Drive, Columbia, MO 65201 Kansas City VA Medical Center, 4801 East Linwood Blvd, Kansas City, MO 64126 Dwight D. Eisenhower VA Medical Center, 4101 S. 4th Street Trafficway, Leavenworth, KS 66048 John J. Pershing VA Medical Center, 1500 N. Westwood Blvd, Poplar Bluff, MO 63901 St Louis Medical Center, John Cochran Division, 915 North Grand Blvd, St. Louis, MO 63106 Colmery-O Neil VA Medical Center, 2200 Gage Blvd, Topeka, KS 66622 Robert J. Dole VA Medical Center, 5500 E. Kellogg Avenue, Wichita, KS 67218 Attachment B:   Covid-19 Ag Test Card (40 test) Kits 195-000 Covid-19 Ag Self-Test Card (24 test) Kits 195-264 Test Card Control Kits 195-080 COL 38 63 15 KC   8 5 LEA 13   13 PB   188 5 STL 900   5 TOP 13   13 WIC   8 2
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/5420d21733364ca2975a6a0567bac4b8/view)
 
Place of Performance
Address: Department of Veteran Affairs VISN 15 - Multiple Facilities See Attachment A in Statement of Work Below 66048-5014, USA
Zip Code: 66048-5014
Country: USA
 
Record
SN06510653-F 20221106/221104230059 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.