Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF NOVEMBER 09, 2022 SAM #7649
SOURCES SOUGHT

Y -- Building 34 Chiller Replacement, DSCR Richmond

Notice Date
11/7/2022 8:01:27 AM
 
Notice Type
Sources Sought
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
W2SD ENDIST NORFOLK NORFOLK VA 23510-1096 USA
 
ZIP Code
23510-1096
 
Solicitation Number
W9123623B5004
 
Response Due
11/28/2022 9:00:00 AM
 
Point of Contact
Jack Bass, Phone: 757-201-7385, Nicholas Lizotte, Phone: 7572017310
 
E-Mail Address
Jack.B.Bass@usace.army.mil, nicholas.lizotte@usace.army.mil
(Jack.B.Bass@usace.army.mil, nicholas.lizotte@usace.army.mil)
 
Description
SOURCES SOUGHT Building 34 Chiller Replacement, DSCR Richmond This is a sources sought notice only; it is not a request for competitive proposals.� There are no solicitations, specifications, and/or drawings available at this time. This Sources Sought Notice is for informational purposes only to determine the interest, and availability, of potential qualified contractors. The Government will not reimburse respondents for any cost incurred in preparation of a response to this notice. The Government intends to use responses to this Sources Sought to make appropriate acquisition decisions for the project.� NO AWARD will be made from this Sources Sought notice. ALL INTERESTED FIRMS SHOULD RESPOND TO THIS NOTICE NO MATTER WHAT BUSINESS SIZE UNDER THE NAICS CODE 236220. Project Description: The Norfolk District, Corps of Engineers is conducting Market Research to identify potential Sources for the Building 34 Chiller Replacement project at DSCR, Chesterfield County Richmond, Virginia. The work would include demolishing Building 34 existing chilled water equipment, which includes but not limited to: water cooled chiller, cooling tower, and pumps located in two mechanical rooms adjacent to the building entrance and replace with a similar capacity air cooled chiller with supporting equipment (pumps, expansion tanks, piping system, air separators, etc.) and new electrical infrastructure support (feeder and branch circuit, disconnect switches etc.) extending from B34 to new equipment. The existing diesel generator will be demolished and replaced with a new natural gas generator with Automatic Transfer Switch (ATS) to support back-up operation. The air cooled chiller will be placed outdoor in the outdoor equipment area adjacent to the mechanical room. Existing electrical infrastructure to be demolished along with the existing equipment removed. Minor modification to the building structure/site work will be needed to allow removal of existing equipment and installation of new equipment in mechanical rooms and outdoor equipment yard including but not limited to: capping roofing penetrations after cooling tower is removed, wall demolition and new work, removing existing concrete equipment pads, and new underground gas piping for gas generator. The anticipated Period of Performance is 180 calendar days. The Contracting Officer has classified this requirement as Construction of Commercial and Institutional Building Constructions, North American Industry Classification System (NAICS) code 236220. The small business size standard is $36.5 million.� In accordance with DFARS 236.204(i), the magnitude of construction for this project is between $1,000,000 and $5,000,000. Contractors will be required to submit bonding documents prior to award.� Bonding documents are not required for this Sources Sought. THIS SOURCES SOUGHT ANNOUNCEMENT IS NOT A REQUEST FOR PROPOSAL. It is a market research tool being used to determine the availability and adequacy of potential sources prior to determining the acquisition strategy. The Government is not obligated to and will not pay for any information received from potential sources as a result of this announcement. It is requested that interested sources submit to the contracting office a brief capabilities statement package (no more than 3 pages in length, single-spaced, 12 point font minimum) demonstrating ability to perform the requested services identified in this survey. Response Requirements: 1. Offeror's name, addresses, points of contact, telephone numbers, and e-mail addresses. 2. Offeror's business size to include each designation as Certified Small Businesses, 8(a) contractors, HUBZone Certified Small Business Concerns, Service Disabled Veteran Owned Small Businesses and Woman Owned Businesses. For 8(a) Contractors, please include proposed graduation date from the 8(a) Program. 3.� Offeror�s bonding capability (construction bonding level per contract and aggregate construction bonding level, both expressed in dollars). 4. Provide a narrative indicating the primary nature of your business.� Narratives shall be no longer than five (5) pages and shall demonstrate experience in a similar type of work as described, at a similar contract value, and in a similar location. 5. Description of Experience � Provide two (2) to three (3) examples of successful projects similar to requirements described in the project description above, within the past five (5) years. If a specialty sub-contractor is used, the sub-contractor shall also provide work examples and experience. Based on definitions above, for each project submitted include: a. Current percentage of construction complete and the date when it was or will be completed. b. Scope of the project c. Size of the project d. Dollar value of the project e. The portion and percentage of work that was self-performed The order of magnitude for this effort is estimated between $1,000,000.00 and $5,000,000.00. Contractors will be required to submit bonding documents prior to award. Bonding documents are not required for this sources sought.� The project is located near areas available for work during regular working hours (7:00am to 4:30pm). No holiday work is anticipated.� This Sources Sought Announcement is not a request for competitive proposals. Since this is a Sources Sought Announcement only, no evaluation letters and/or results will be issued to the respondents.� No solicitation exists and solicitation requests will not be acknowledged.� USACE Norfolk District is not seeking or accepting unsolicited proposals, and will not accept telephone inquiries.� All questions and correspondence shall be directed via email at Jack Bass at Jack.B.Bass@usace.army.mil and a copy to Nicholas Lizotte at Nicholas.Lizotte@usace.army.mil Responses: All responses to this announcement may be sent electronically to Jack Bass at Jack.B.Bass@usace.army.mil and Nicholas Lizotte at Nicholas.Lizotte@usace.army.mil later than 12:00 p.m. EST, 28 November 2022.� Primary Point of Contact: Jack Bass Contract Specialist Jack.B.Bass@usace.army.mil O: 757 201-7385 F: 757-201-7183 USACE District, Norfolk Secondary Point of Contact: Nicholas Lizotte Contracting Officer Nicholas.lizotte@usace.army.mil O: 757-201-7310 F: 757-201-7183 USACE District, Norfolk
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/40ecd049f2074410b203c0165c286456/view)
 
Place of Performance
Address: Richmond, VA 23297, USA
Zip Code: 23297
Country: USA
 
Record
SN06511870-F 20221109/221107230103 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.