SOLICITATION NOTICE
Y -- 620A4-18-212 Pharmacy USP 800 Renovation
- Notice Date
- 11/22/2022 6:58:50 AM
- Notice Type
- Solicitation
- NAICS
- 236220
— Commercial and Institutional Building Construction
- Contracting Office
- 242-NETWORK CONTRACT OFFICE 02 (36C242) ALBANY NY 12208 USA
- ZIP Code
- 12208
- Solicitation Number
- 36C24223B0001
- Response Due
- 12/7/2022 11:00:00 AM
- Archive Date
- 01/06/2023
- Point of Contact
- Michael j Giaquinto, Contracting Officer
- E-Mail Address
-
michael.giaquinto2@va.gov
(michael.giaquinto2@va.gov)
- Awardee
- null
- Description
- IFB 36C24223B0001 RFI Responses The fixture schedule is missing the Fail-Safe series letters for type L3 & we need the letter code that identifies the fixture series: Response: The Fail-Safe fixture shall be from the FSP series or approved equal. Please see the questions from the contractors for the USP project. Please respond at your earliest and provide the site visit sign in sheet, Spec 08 42 29 AUTOMATIC ENTRANCES Part 1.2 Related Requirement for aluminum framed lites in Spec 08 41 13 ALUMINUM FRAMED ENTRANCES AND STOREFRONTS. This spec is missing, was it intended to be included in the bid docs? Please minimally provide a finish for aluminum doors. Response: Spec section 08 41 13 will not be required. Tempered glass will need to be noted for all vision lights in doors. All operable doors are picked up in another section. What permits are required for performing this scope of work and who will be paying for said permits if required? Response: None. Can they existing epoxy flooring and base in the compounding suite remain and just be resurfaced? Response: Warranty for the epoxy flooring is required per the manufacturer specification. Install flooring to meet warranty requirements. Please provide photos of crane location and building elevation at temporary stair locations Response: Here is a Google Image. VA to verify Crane Location. Can you provide the contact information for the roofing company that holds the new roof warranty? Response: information will be provided to the awardee contractor Will the Site Superintendent, if duly qualified, be permitted to also serve in the roles of CQC and SSHO or will a separate individual be required for either of those two roles? Response: yes as long as these 2 roles(CQC & SSHO) does not interfere with the daily task for the site Superintendent .
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/d8268323d0c54d2eb4b8d241d498e23a/view)
- Record
- SN06525870-F 20221124/221125065242 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |