SOURCES SOUGHT
65 -- DEFIBRILLATORS
- Notice Date
- 11/22/2022 11:44:15 AM
- Notice Type
- Sources Sought
- NAICS
- 334510
— Electromedical and Electrotherapeutic Apparatus Manufacturing
- Contracting Office
- 246-NETWORK CONTRACTING OFFICE 6 (36C246) HAMPTON VA 23667 USA
- ZIP Code
- 23667
- Solicitation Number
- 36C24623R0011
- Response Due
- 11/28/2022 8:00:00 AM
- Archive Date
- 01/27/2023
- Point of Contact
- Contract Officer, Kim Pauley, Phone: No Phone Calls Please
- E-Mail Address
-
kim.pauley@va.gov
(kim.pauley@va.gov)
- Awardee
- null
- Description
- This is sources sought for the replacement of the existing fleet of both the defibrillators and AED devices at the Charles George VA Medical Center. The fleet includes 41 R Series Plus AED s, 39 Basic Life Support AED s and 3 Non-Clinical Training AED s. Replacement includes deliver to the facility and unpack the equipment for the Biomedical Engineering Department. The vendor will provide basic onsite setup on the equipment and provide two days of onsite technical training for the Biomedical Department Personnel. The number of staff has not been noted for the Contracting Officer. Please respond to kim.pauley@va.gov no later than November 28, 2022 at 11:00 AM EST if your company can supply this product. Please provide your SAMS number and socio-economic status if you are interested in this acquisition. Below are the salient characteristics that are essential. Energy Selection: Joules Paddle Controls: Charge, discharge, energy select Waveform Shape: Biphasic Biphasic, energy, J: 1-10, 15, 20, 30, 50, 75, 100, 120, 150, 200 ECG Monitor 3-channel color LCD screen External Pacemaker Specific Oxygen: SPO2 End-tidal CO2: ETCO2 Non-invasive blood pressure: NIBP Battery Power Lithium Ion Charge Time <4 Hours Electronic filter to remove chest compression artifacts from ECG Ability for device to provide CPR feedback both audibly and visually Device must be able to self-test on power-up, daily, weekly, or more in an automatic fashion Device must have FIPS 140-2 certification Automated clock syncing via WIFI Software for wireless defibrillator and AED readiness monitoring and management Software for CODE data review Defibrillators must have a 5-year warranty AEDs must have CPR feedback for users during a resuscitation event
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/053d73b8d9c34674afb2d194094924aa/view)
- Place of Performance
- Address: 1100 Tunnel Road, Asheville, NC 28805, USA
- Zip Code: 28805
- Country: USA
- Zip Code: 28805
- Record
- SN06526519-F 20221124/221125065249 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)