Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF DECEMBER 10, 2022 SAM #7680
SOLICITATION NOTICE

Y -- FY23: NRM-Tier 1 (PROJ: 548-23-122) D/B Install Additional Pump on OR Chilled Water Loop

Notice Date
12/8/2022 11:26:37 AM
 
Notice Type
Solicitation
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
248-NETWORK CONTRACT OFFICE 8 (36C248) TAMPA FL 33637 USA
 
ZIP Code
33637
 
Solicitation Number
36C24823R0051_1
 
Response Due
12/13/2022 9:00:00 AM
 
Archive Date
12/28/2022
 
Point of Contact
Stacy Figlinski, Contracting Officer, Phone: (813) 940-2788
 
E-Mail Address
Stacy.Figlinski@va.gov
(Stacy.Figlinski@va.gov)
 
Small Business Set-Aside
SDVOSBC Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
 
Description
This solicitation is 100% Set-Aside for Service Disabled Veteran Owned Small Businesses (SDVOSB).� POP is 120 Days from NTP. AMENDMENT 2 - P1 Due Date extended to Dec 13, 2022 at 12:00 PM EST; P1 Site Visit Sign In Sheet Provided. AMENDMENT 1 - Change to Site Visit and RFI dates. See attachment titled ""S06 36C24823R0051 0001"". The contractor shall provide all labor, tools, and materials necessary for the following work: Install new pump on existing OR chilled water loop. The pump will match existing and will be installed in parallel with the two (2) existing pumps. Pumping capacity will be designed to carry full load. Control configuration will allow either of the three (3) pumps to act as the primary. Install new Eaton VFD for the new pump. The new VFD will match existing and will be located adjacent to the (2) existing pump VFDs. New VFD to have manual disconnect. The power feed to the two (2) existing pumps will be rewired by the contractor so that the pumps are not on the same electrical panel. New DDC controls with BACNET communication. Contractor shall use our installed BACnet compatible building automation system (BAS) for this project. Contractor shall provide all engineering and technical assistance required for integration into BAS. All devices installed shall be BACnet tested and approved and work seamlessly with existing BAS.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/19bfa78b4054408aaec1accce896d31a/view)
 
Place of Performance
Address: FL 33410, USA
Zip Code: 33410
Country: USA
 
Record
SN06538768-F 20221210/221208230101 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.