SOLICITATION NOTICE
X -- General Services Administration (GSA) Office Lease; Durant,OK
- Notice Date
- 12/13/2022 9:26:14 AM
- Notice Type
- Presolicitation
- Contracting Office
- PBS R7 FORT WORTH TX 76102 USA
- ZIP Code
- 76102
- Solicitation Number
- 1OK2104
- Response Due
- 1/3/2023 3:30:00 AM
- Point of Contact
- Zachary Crawford, Phone: 8178508449
- E-Mail Address
-
zachary.crawford@gsa.gov
(zachary.crawford@gsa.gov)
- Description
- Presolicitation Notice/Advertisement GSA Public Buildings Service U.S. GOVERNMENT General Services Administration (GSA) seeks to lease the following space: State: Oklahoma City: Durant Delineated Area: North: Folsom Rd, N. Washington Ave, Red Bud Ln, Route 78, Magnolia St, Old US 70, US 70, South: McKennon Rd/Route 70E, E2130 Rd, E Main St, S. McKinley Ave, Smiser Rd, E2120Rd, East: N3770 Rd, Old hwy 70, N. Roberts Rd, West: N3675 Rd, E 3065 Rd, N3680 Rd, E2110 Rd, N3682 Rd Minimum Sq. Ft. (ABOA): 4,251.00 Maximum Sq. Ft. (ABOA): 4,251.00 Space Type: Office / Storage / Special Parking Spaces (Total): 10 Parking Spaces (Surface): 10 Parking Spaces (Structured): 0 Parking Spaces (Reserved): 0 Full Term: 15 Years Firm Term: 10 Years Option Term: N/A Additional Requirements: AGENCY UNIQUE REQUIREMENTS 1. This requirement is for a law enforcement agency. 2. The Security Level is II. 3. The Tenant will provide the site's telecommunications service requirements in terms of 100 Mbps for data and 10 Mbps for Phone. Depending upon the site, multiple circuits may be required. The Lessor will be required to procure the connection (circuit), not telecom devices, based upon guidance provided by Tenant Security. 11/2022 4. 10 surface parking spaces are required. Facilities with underground parking must have access-controlled parking restricted to building Tenants. Open and/or general public parking is not permitted below the building proposed for the Tenant office. A mixed-Tenant building with public parking within 20'-0"" of the interior perimeter wall will not be considered. 5. The proposed site must not be within 640'-0"" of any facilities identified by the ISC as ""hazardous materials transportation/storage facilities."" o Hazardous locations include facilities with potential environmental threats (e.g., fuel storage areas, gas stations, chemical manufacturing facilities, and railroad lines transporting hazardous material). o Special consideration should be given to exclude sites located near hazardous areas, such as bulk storage sites (e.g., hazardous materials storage sites, water purification centers, above ground fuel storage, and rail yards). o It is preferred that the proposed facility not be located near ""Low Risk Facilities"" (e.g., day care centers, senior centers, schools, hospitals, and religious/rehabilitation/social service centers). 6. The proposed facility must not be located within 400'- 0"" of public defenders, Immigration and Customs Enforcement (ICE), probation offices, Internal Revenue Service (IRS), universities, other businesses or facilities deemed unacceptable by Tenant Security for safety purposes. This requirement may be waived by Tenant Security if no other facility 11/2022 7. All space must be contiguous, on the 2nd floor or higher. Space on the first floor will be considered only when no other space is available, or if deemed appropriate by the Tenant. First-floor spaces require additional security measures. 8. If the exterior skin of the building is not of substantial construction as determined by Tenant Security (e.g., concrete, concrete masonry unit, brick), and does not meet the Tenant�s forced entry protection requirements, interior assembly of perimeter partitions must be constructed in accordance with Partition Type A7 specifications. 9. All exterior perimeter windows must have fragment retention film, except at SCIF rooms, which must have film rated for radio frequency (RF) and infrared (IR) shielding and blast film, as specified within the POR. 10. All perimeter windows less than 18'-0"" from grade or accessible platform (e.g., air conditioners, fire stairs, adjacent roofs, ledges, or windows) must have forced entry protection such as man bars or security screening. Assessment of accessible platform(s) will be determined by Tenant Security. 11. Roofs less than 18'-0"" from grade or an accessible platform also must meet the same forced entry protection and sound attenuation requirements as the building�s perimeter partitions. Metal roofs less than 18'- 0"" from grade or accessible platform must meet the same forced entry protection and sound attenuation requirements as the perimeter partitions. 12. Metal structure buildings that will have an ""Open Storage Secure"" security posture must have the secured perimeter constructed to meet forced entry protection requirements, Partition Type A7, or approved equivalent by Tenant and CO. 11/2022 13. If the space and/or building are of wood joist construction, or in an historical building, additional security measures will be required, such as increased sound isolation, hard capping the ceiling of the suite, and providing an additional layer of plywood over existing floor systems. 14. Skylights must be removed or secured with forced entry protection and applied opaque film to prevent visual observation Offered space must meet Government requirements for fire safety, accessibility, seismic, and sustainability standards per the terms of the Lease. A fully serviced lease is required. Offered space shall not be in the 1-percent-annual chance floodplain (formerly referred to as 100-year floodplain). Entities are advised to familiarize themselves with the telecommunications prohibitions outlined under Section 889 of the FY19 National Defense Authorization Act (NDAA), as implemented by the Federal Acquisition Regulation (FAR). ). For more information, visit: https://acquisition.gov/FAR- Case-2019-009/889_Part_B. Expressions of Interest Due: Market Survey (Estimated): Occupancy (Estimated): Send Expressions of Interest to: Name/Title: Zachary Crawford , LCO Email Address: Zachary.crawford@gsa.gov Government Contact Information Lease Contracting Officer Zachary Crawford
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/fdc85c824eb441a2bc3ee4c5d8a18ffe/view)
- Place of Performance
- Address: Fort Worth, TX 76103, USA
- Zip Code: 76103
- Country: USA
- Zip Code: 76103
- Record
- SN06542312-F 20221215/221214015836 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |