Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF DECEMBER 23, 2022 SAM #7696
SOURCES SOUGHT

66 -- Lab Equipment - Leica Aperio GT 450 Scanner

Notice Date
12/21/2022 12:54:33 PM
 
Notice Type
Sources Sought
 
NAICS
339113 — Surgical Appliance and Supplies Manufacturing
 
Contracting Office
RPO EAST (36C24E) PITTSBURGH PA 15212 USA
 
ZIP Code
15212
 
Solicitation Number
36C24E23Q0038
 
Response Due
12/28/2022 12:00:00 PM
 
Archive Date
01/27/2023
 
Point of Contact
Ann Marie Stewart, Contracting Officer, Phone: 401-919-0878
 
E-Mail Address
annmarie.stewart@va.gov
(annmarie.stewart@va.gov)
 
Awardee
null
 
Description
SUMMARY: This is a Sources Sought notice and not a request for quotes. This request is solely for the purpose of conducting market research to enhance VHA s understanding of the market s offered products, services and capabilities. The Government will not pay any costs for responses submitted in response to this Sources Sought. This Sources Sought notice provides an opportunity for respondents to submit their notice of ability, and their available products and services in response to the requirement described below. Vendors are being invited to submit information relative to their potential of fulfilling the requirement below, in the form of a capability response that addresses the specific requirement identified in this Sources Sought. The Veterans Health Administration (VHA) is seeking a vendor to provide the following products and/or services below. Please see the General Requirements section below for the requested products/services and descriptions. This Sources Sought is to facilitate the Contracting Officer s review of the market base, for acquisition planning, size determination, and procurement strategy. GENERAL REQUIREMENTS: The Atlanta VA Medical Center requires brand name or equal equipment for the Aperio GT 450 Next Generation Scanner. Below are the following items required. LEICA 23GT450 Aperio GT 450 Next Generation Scanner LEICA 23GT450SAM Aperio GT450 Scanner Admin MGR Server LEICA 23GT450SAMSW Aperio GT 450 Scanner Admin MGR SAM SW REQUIRED TECHNICAL SPECIFICATIONS: Salient (minimum) Characteristics Equipment must meet the following specifications: Automated pathological slide scanner with a high throughput and resolution of scanning of at least: Continuous rack loading 60 seconds per slide Overall output of up to 81 slides per hour Magnification of 40x Resolution of 0.26 m/pixel at 40x magnification Ability to have no touch scanning and continuous loading of slides on racks with a maximum slide capacity of 450 The device should be a tabletop device Ability to be integrated with a versatile software and server for the scanning of the pathological slides from our Veteran patients: Slide management software that provides easy access for slide sharing for consultations and collaborations between our tumor board members. Images must be in the svs type file format, which is suitable for slide de-identification and files can be exported from the slide for image analysis. The product capabilities and salient characteristics identified above by a brand name or equal description are intended to be descriptive, not restrictive, and to indicate the quality and characteristics of the product that will be satisfactory. Quotes offering ""equal products (including products of the brand name manufacturer other than the one described by the brand name) will be considered if such product is clearly identified in the quote and is determined by the VA to meet fully the salient characteristics on above products. If offering an equivalent product, the brand name of the equivalent product shall be clearly identified in the quote. Unless visibly identified as an equivalent product, offered items shall be considered as the brand name product referenced in this announcement. RESPONSE COMMITMENT: I. Response: A. Capability statement and a list of the salient characteristics. Please provide your socioeconomic status, and size classification (large business, small business, SDVOSB, VOSB, etc.), and the approximate shipping time from the date of order. Please indicate if your company is an authorized dealer for this product. No 3rd part resellers are acceptable. All responses should be directed to annmarie.stewart@va.gov by December 28, 2022, 3PM EST. B. Submittals furnished will not be returned to the sender. No debriefs will be conducted. Eligibility in participating in a future acquisition does not depend upon a response to this notice. C. Proprietary information is neither requested nor desired. If such information is submitted, it must clearly be marked ""proprietary"" on every sheet containing such information, and the proprietary information must be segregated to the maximum extent practicable from other portions of the response (e.g., use an attachment or exhibit). II. Timeline: This notice will close on December 28, 2022, 3PM EST III. Delivery Address: U.S. Department of Veterans Affairs Atlanta VA Medical Center 1670 Clairmont Rd, Decatur, GA 30033 Notes: 1. This Sources Sought is for planning purposes only, and does not constitute a commitment, implied or otherwise, that a procurement action will follow. The Department of Veterans Affairs will use the information submitted in response to this notice at its discretion and will not provide comments to any submission; however, The Department of Veterans Affairs reserves the right to contact any respondent to this notice for the sole purpose of enhancing The Department of Veteran Affairs understanding of the notice submission. 2. The content of any responses to this notice may be reflected in any subsequent solicitation, except for content marked or designated as business confidential or proprietary which will be fully protected from release outside the government. The Department of Veteran Affairs Contracting Office POC: Ann Marie Stewart Contracting Officer annmarie.stewart@va.gov
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/20e8c8dd691741c4a26b187cc1a67961/view)
 
Place of Performance
Address: US Department of Veterans Affairs Atlanta VA Medical Center Research Office 1670 Clairmont Rd, Decatur, GA 30033, USA
Zip Code: 30033
Country: USA
 
Record
SN06549948-F 20221223/221221230112 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.