Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF DECEMBER 23, 2022 SAM #7696
SOURCES SOUGHT

99 -- Facilitate Other Maintenance (FOM) Storage Shelter

Notice Date
12/21/2022 10:20:44 AM
 
Notice Type
Sources Sought
 
NAICS
332311 — Prefabricated Metal Building and Component Manufacturing
 
Contracting Office
FA8571 MAINT CONTRACTING AFSC PZIM ROBINS AFB GA 31098-1672 USA
 
ZIP Code
31098-1672
 
Solicitation Number
L3WA34
 
Response Due
1/15/2023 2:00:00 PM
 
Archive Date
01/15/2024
 
Point of Contact
David Guo, Phyllis Vail, Phone: 4783272660
 
E-Mail Address
David.Guo.2@us.af.mil, phyllis.vail@us.af.mil
(David.Guo.2@us.af.mil, phyllis.vail@us.af.mil)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
FOM Storage Shelter L3WA34 19 December 2022 CAUTION: This market survey is being conducted to identify potential sources that may possess the expertise, capabilities, and experience to meet the requirements for qualification and production of the FOM Storage Shelter for use by United States Air Force (USAF) personnel.� The level of security clearance and amount of foreign participation in this requirement has not been determined.� Contractors/Institutions responding to this market research are placed on notice that participation in this survey may not ensure participation in future solicitations or contract awards.� The government will not reimburse participants for any expenses associated with their participation in this survey. INSTRUCTIONS: Below is a document containing a description of the FOM Storage Shelter requirement and a Contractor Capability Survey, which allows you to provide your company�s capability. If, after reviewing these documents, you desire to participate in the market research, you should provide documentation that supports your company�s capability in meeting these requirements.� Failure to provide documentation may result in the government being unable to adequately assess your capabilities.� If you lack sufficient experience in a particular area, please provide details explaining how you would overcome the lack of experience/capabilities in order to perform that portion of the requirement (i.e., teaming, subcontracting, etc.) Identify any areas of work that your organization believes should be broken out exclusively for Small Business. Both large and small businesses are encouraged to participate in this Market Research.� Joint ventures or teaming arrangements are encouraged. Questions relative to this market survey should be addressed to David Guo (David.guo.2@us.af.mil) and Ishan Patel (Ishan.Patel@us.af.mil). Telephone responses will not be accepted. FOM Storage Shelter PURPOSE/DESCRIPTION ����� The Government is conducting market research to identify potential sources that possess the production expertise, capabilities, and experience to meet qualification requirements for the production and installation of FOM Shelter. Install fabric shelter which includes: Should be fully enclosed Fabric material should be flame retardant Exterior dimensions 174ft (width) x 820ft (length) x 20ft (height at eave), 52ft (height at center peak/ridge) Fabric Shelter should support wind loads 105mph (Risk Category I) and 115mph (Risk Category II) Dead loads should support lighting and fire suppression 2 roll up doors in each end wall and 3 roll up doors along each length (10 total) 6 doors for basic life safety egress along with emergency exit signs HVAC system for modular space, fire alarm panel and fire riser mechanical room (lockable) Lighting: LED lights Estimating 3,500,000 lumens for the fabric shelter interior Contractor will install all electrical, water & sewage/plumbing Electrical requirements: Estimating 480V/277V 3 phase, 600 Amp service 120/208 receptacle power Outside disconnect Fire suppression: Dry pipe sprinkler system (prevent frozen and burst pipes) Modular Space: 60ft x 40ft & 30ft x 15ft for offices (with HVAC, cubicles, desks and electrical) Total of approx. 80 workers between day and swing shift Include 5 secured offices and 15 cubicles (with desks) 58ft x 30ft for break room (with electrical and HVAC) 25ft x 20ft for restrooms (with electrical, plumbing and HVAC) 2 toilets and 2 urinals for male bathroom 3 toilets for female bathroom CONTRACTOR CAPABILITY SURVEY FOM Storage Shelter Part I.� Business Information ����������� Please provide the following business information for your company/institution and for any teaming or joint venture partners: ����� Company/Institute Name: ����� Address: ����� Point of Contact: ����� CAGE Code: Phone Number: E-mail Address: Web Page URL: ����� Size of business pursuant to North American Industry Classification System (NAICS) Code:� 332311 - Prefabricated Metal Building and Component Manufacturing ������ Based on the above NAICS Code, state whether your company is: Small Business���������������������������������������������� (Yes / No) Woman Owned Small Business�������������������� (Yes / No) Small Disadvantaged Business��������� ����������� (Yes / No) 8(a) Certified������������������������������������������������� (Yes / No) HUBZone Certified��������������������������������������� (Yes / No) Veteran Owned Small Business�������������������� (Yes / No) Service Disabled Veteran Small Business���� (Yes / No) ����� Central Contractor Registration (CCR).� ����������� (Yes / No) ����� A statement as to whether your company is domestically or foreign owned (if foreign, please indicate the country of ownership). Written responses via e-mails please, must be received no later than close of business 15 January 2023.� Please mail email the following individuals: David Guo (David.guo.2@us.af.mil) Ishan Patel (Ishan.Patel@us.af.mil) Phyllis Vail (phyllis.vail@us.af.mil) Part II. Capability Survey Questions General Capability Questions: Describe briefly the capabilities of your facility and the nature of the goods and/or services you provide.� Include a description of your staff composition and management structure. Describe your company's past experience on previous projects similar in complexity to this requirement.� Include contract numbers, a brief description of the work performed, period of performance, agency/organization supported, and individual point of contact (Contracting Officer or Program Manager). What quality assurance processes and test qualification practices does your company employ?� Please provide a description of your quality program (ISO 9001, AS9100, etc.) Are there specific requirements in the documentation that we provide that would currently preclude your product from being a viable solution to our requirement? Include a detailed listing of facilities and equipment, including quantities, required to satisfy the requirements of this effort. Provide an outline of the proposed process, including inspections. Commerciality Questions: Are there established catalog or market prices for our requirement?� If you offer this product and/or service to both U.S. Government and commercial sources, is the same workforce used for both the U.S. Government and general public?� Is our requirement offered to both under similar terms and conditions?� Briefly describe any differences. Describe your standard warranty and return process for goods and services furnished to the government for items similar in nature to this requirement. �
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/0494fb67e1b84959b55a36807acbdfa4/view)
 
Place of Performance
Address: Warner Robins, GA 31098, USA
Zip Code: 31098
Country: USA
 
Record
SN06549971-F 20221223/221221230112 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.