Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JANUARY 11, 2023 SAM #7715
SOURCES SOUGHT

J -- Washington Aqueduct Venturi Pressure Transmitter Replacement

Notice Date
1/9/2023 11:31:09 AM
 
Notice Type
Sources Sought
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
W2SD ENDIST BALTIMORE BALTIMORE MD 21201-2526 USA
 
ZIP Code
21201-2526
 
Solicitation Number
PANNAD-22-P-0000-003521
 
Response Due
1/16/2023 8:00:00 AM
 
Point of Contact
Rosemarie Rollins, Phone: 4109623529, Vincent Gier, Phone: 4109622584
 
E-Mail Address
rosemarie.e.rollins@usace.army.mil, vincent.j.gier@usace.army.mil
(rosemarie.e.rollins@usace.army.mil, vincent.j.gier@usace.army.mil)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
The purpose of this contract action is to perform maintenance on the venturi tube taps following replacement of the transmitters and associated plumbing, electrical, and mounting accessories to provide accurate water flowrate and head pressure readings. The Contractor shall provide all labor, supervision, materials, equipment, and supplies to complete the following work for each of the (26) filter venturis in the East Filter Building: - Clean high-pressure and low-pressure venturi tube taps using rodding and flushing procedures. - Replace piping, valves, and fittings from the venturi taps to the Rate of Flow transmitter and Loss of Head transmitter. Bronze or steel isolation valves shall be replaced with 304 stainless steel type. All other material types shall be replaced in kind. - Replace the Rate of Flow transmitter and the Loss of Head transmitter and perform calibration on the new transmitters. Replace all conduits, fittings, and conductors between the transmitters and the control console. Incorporate a means to prevent water ingress into the transmitters via the incoming conduit (i.e. drip loop, grommets, seals, etc.). Provide a calibration report for each transmitter. - Replace the mounting posts supporting the transmitters with 304 stainless steel posts and properly mount the transmitters for visual operation of the screens. Please see attached draft Performance Work Statement (PWS) for more details.�Interested vendors that are capable of fulfilling the PWS may submit a capabilities statement by the closing date for consideration. Email capabilities statement to Rosemarie.E.Rollins@usace.army.mil and Ryandale.R.Fernandez@usace.army.mil referencing the sources sought notice number PANNAD-22-P-0000 003521.� Telephone inquiries will not be accepted or acknowledged, and no feedback will be provided.� If you have any questions, contact Rosemarie Rollins at Rosemarie.E.Rollins@usace.army.mil.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/14195240fe074a819332984203412235/view)
 
Place of Performance
Address: Washington, DC 20016, USA
Zip Code: 20016
Country: USA
 
Record
SN06559799-F 20230111/230109230107 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.