SOLICITATION NOTICE
65 -- Olink Proteomics Olink�Target Reagent kits panels
- Notice Date
- 1/25/2023 6:51:41 AM
- Notice Type
- Presolicitation
- NAICS
- 621511
— Medical Laboratories
- Contracting Office
- W4PZ USA MED RSCH ACQUIS ACT FORT DETRICK MD 21702-5014 USA
- ZIP Code
- 21702-5014
- Solicitation Number
- PANMRA-23-P-0000-000284-Olink_Presolicitation
- Response Due
- 2/10/2023 7:00:00 AM
- Point of Contact
- Linda Taylor Hinson, Phone: 3016192127, Sharew Hailu
- E-Mail Address
-
linda.t.hinson.civ@health.mil, sharew.hailu.civ@health.mil
(linda.t.hinson.civ@health.mil, sharew.hailu.civ@health.mil)
- Description
- This is a pre-soliciation notice in accordance with FAR Part 5.� A Soliciation is being forecasted on or about 10 Februrary 2023.� The purpose of this Brand Name or Equal to Indefinte Delivery Indefinte Quantity (IDIQ) is to provide Walter Reed Army Institute of Research (WRAIR). Minimum Essential Characteristics (MECs) The Walter Reed Army Institute of Research (WRAIR), Center for Military Psychiatry and Neurosciences Division (CMPN) Medical Readiness Systems Biology Branch (MRSB) is requesting Olink Proteomics Olink� Target reagent kits panels or Equal to the following: Minimum Essential Characteristics (MEC) for Olink Proteomics: Olink� Target 96 Mouse Exploratory Reagent kit (95380) High throughput analysis of at least 92 protein biomarkers across 96 samples simultaneously with no loss in data quality. Detect biomarkers both established and exploratory. Access to list of all protein biomarkers via Olink�s biomarker and panel library. Reagents utilize Proximity Extension Assay technology to conserve data purity. Detect protein targets with high precision and sensitivity from only 1 �L sample. Should be compatible with serum, plasma, and other type of biological sample starting material. Must be able to be used on the Fluidigm� BioMark� system and The Juno� system. Results reported in standard concentration units(pg/mL) or NPX units Minimum Essential Characteristics (MEC) for Olink Proteomics: Olink� Target 96 Inflammation Reagent Kit 95302) High throughput analysis of at least 92 protein biomarkers across 96 samples simultaneously with no loss in data quality. Detect biomarkers both established and exploratory. Access to list of all protein biomarkers via Olink�s biomarker and panel library. Reagents utilize Proximity Extension Assay technology to conserve data purity. Detect protein targets with high precision and sensitivity from only 1 �L sample. Should be compatible with serum, plasma, and other type of biological sample starting material. Must be able to be used on the Fluidigm� BioMark� system and The Juno� system. Results reported in standard concentration units(pg/mL) or NPX units Minimum Essential Characteristics (MEC) for Olink Proteomics: Olink� Target 96 Immuno-Oncology Reagent Kit (95311) High throughput analysis of at least 92 protein biomarkers across 96 samples simultaneously with no loss in data quality. Detect biomarkers both established and exploratory. Access to list of all protein biomarkers via Olink�s biomarker and panel library. Reagents utilize Proximity Extension Assay technology to conserve data purity. Detect protein targets with high precision and sensitivity from only 1 �L sample. Should be compatible with serum, plasma, and other type of biological sample starting material. Must be able to be used on the Fluidigm� BioMark� system and The Juno� system. Results reported in standard concentration units(pg/mL) or NPX units Minimum Essential Characteristics (MEC) for Olink Proteomics: Olink� Target 96 Immune Response Reagent Kit (95320) High throughput analysis of at least 92 protein biomarkers across 96 samples simultaneously with no loss in data quality. Detect biomarkers both established and exploratory. Access to list of all protein biomarkers via Olink�s biomarker and panel library. Reagents utilize Proximity Extension Assay technology to conserve data purity. Detect protein targets with high precision and sensitivity from only 1 �L sample. Should be compatible with serum, plasma, and other type of biological sample starting material. Must be able to be used on the Fluidigm� BioMark� system and The Juno� system. Results reported in standard concentration units(pg/mL) or NPX units Minimum Essential Characteristics (MEC) for OLink Proteomics: Olink� Target 96 CVD II Reagent Kit (95500) High throughput analysis of at least 92 protein biomarkers across 96 samples simultaneously with no loss in data quality. Detect biomarkers both established and exploratory. Access to list of all protein biomarkers via Olink�s biomarker and panel library. Reagents utilize Proximity Extension Assay technology to conserve data purity. Detect protein targets with high precision and sensitivity from only 1 �L sample. Should be compatible with serum, plasma, and other type of biological sample starting material. Must be able to be used on the Fluidigm� BioMark� system and The Juno� system. Results reported in standard concentration units(pg/mL) or NPX units Minimum Essential Characteristics (MEC) for Olink Proteomics: Olink� Target 96 CVD III Reagent Kit (95611) High throughput analysis of at least 92 protein biomarkers across 96 samples simultaneously with no loss in data quality. Detect biomarkers both established and exploratory. Access to list of all protein biomarkers via Olink�s biomarker and panel library. Reagents utilize Proximity Extension Assay technology to conserve data purity. Detect protein targets with high precision and sensitivity from only 1 �L sample. Should be compatible with serum, plasma, and other type of biological sample starting material. Must be able to be used on the Fluidigm� BioMark� system and The Juno� system. Results reported in standard concentration units(pg/mL) or NPX units Minimum Essential Characteristics (MEC) for Olink Proteomics: Olink� Target 96 Organ Damage Reagent Kit (95331) High throughput analysis of at least 92 protein biomarkers across 96 samples simultaneously with no loss in data quality. Detect biomarkers both established and exploratory. Access to list of all protein biomarkers via Olink�s biomarker and panel library. Reagents utilize Proximity Extension Assay technology to conserve data purity. Detect protein targets with high precision and sensitivity from only 1 �L sample. Should be compatible with serum, plasma, and other type of biological sample starting material. Must be able to be used on the Fluidigm� BioMark� system and The Juno� system. Results reported in standard concentration units(pg/mL) or NPX units Minimum Essential Characteristics (MEC) for Olink Proteomics: Olink Target 96 Metabolism Reagent Kit (95340) High throughput analysis of at least 92 protein biomarkers across 96 samples simultaneously with no loss in data quality. Detect biomarkers both established and exploratory. Access to list of all protein biomarkers via Olink�s biomarker and panel library. Reagents utilize Proximity Extension Assay technology to conserve data purity. Detect protein targets with high precision and sensitivity from only 1 �L sample. Should be compatible with serum, plasma, and other type of biological sample starting material. Must be able to be used on the Fluidigm� BioMark� system and The Juno� system. Results reported in standard concentration units(pg/mL) or NPX units Minimum Essential Characteristics (MEC) for Olink Proteomics: Olink� Target 96 Development Reagent Kit (95352) High throughput analysis of at least 92 protein biomarkers across 96 samples simultaneously with no loss in data quality. Detect biomarkers both established and exploratory. Access to list of all protein biomarkers via Olink�s biomarker and panel library. Reagents utilize Proximity Extension Assay technology to conserve data purity. Detect protein targets with high precision and sensitivity from only 1 �L sample. Should be compatible with serum, plasma, and other type of biological sample starting material. Must be able to be used on the Fluidigm� BioMark� system and The Juno� system. Results reported in standard concentration units(pg/mL) or NPX units Minimum Essential Characteristics (MEC) for Olink Proteomics: Olink� Target 96 Cardiometabolic Reagent Kit (95360) High throughput analysis of at least 92 protein biomarkers across 96 samples simultaneously with no loss in data quality. Detect biomarkers both established and exploratory. Access to list of all protein biomarkers via Olink�s biomarker and panel library. Reagents utilize Proximity Extension Assay technology to conserve data purity. Detect protein targets with high precision and sensitivity from only 1 �L sample. Should be compatible with serum, plasma, and other type of biological sample starting material. Must be able to be used on the Fluidigm� BioMark� system and The Juno� system. Results reported in standard concentration units(pg/mL) or NPX units Minimum Essential Characteristics (MEC) for Olink Proteomics: Olink� Target 96 Cell Regulation Reagent Kit (95370) High throughput analysis of at least 92 protein biomarkers across 96 samples simultaneously with no loss in data quality. Detect biomarkers both established and exploratory. Access to list of all protein biomarkers via Olink�s biomarker and panel library. Reagents utilize Proximity Extension Assay technology to conserve data purity. Detect protein targets with high precision and sensitivity from only 1 �L sample. Should be compatible with serum, plasma, and other type of biological sample starting material. Must be able to be used on the Fluidigm� BioMark� �system and The Juno� system Results reported in standard concentration units(pg/mL) or NPX units Minimum Essential Characteristics (MEC) for Olink Proteomics: Olink� Target 96 Neuro Exploratory Reagent Kit (95391) High throughput analysis of at least 92 protein biomarkers across 96 samples simultaneously with no loss in data quality. Detect biomarkers both established and exploratory. Access to list of all protein biomarkers via Olink�s biomarker and panel library. Reagents utilize Proximity Extension Assay technology to conserve data purity. Detect protein targets with high precision and sensitivity from only 1 �L sample. Should be compatible with serum, plasma, and other type of biological sample starting material. Must be able to be used on the Fluidigm� BioMark� system and The Juno� system. Results reported in standard concentration units(pg/mL) or NPX units Minimum Essential Characteristics (MEC) for Olink Proteomics: Olink� Target 96 Oncology III Reagent Kit (95400) High throughput analysis of at least 92 protein biomarkers across 96 samples simultaneously with no loss in data quality. Detect biomarkers both established and exploratory. Access to list of all protein biomarkers via Olink�s biomarker and panel library. Reagents utilize Proximity Extension Assay technology to conserve data purity. Detect protein targets with high precision and sensitivity from only 1 �L sample. Should be compatible with serum, plasma, and other type of biological sample starting material. Must be able to be used on the Fluidigm� BioMark� system and The Juno� system. Results reported in standard concentration units(pg/mL) or NPX units Minimum Essential Characteristics (MEC) for Olink Proteomics: Olink� Target 96 Oncology II Reagent Kit (95700) High throughput analysis of at least 92 protein biomarkers across 96 samples simultaneously with no loss in data quality. Detect biomarkers both established and exploratory. Access to list of all protein biomarkers via Olink�s biomarker and panel library. Reagents utilize Proximity Extension Assay technology to conserve data purity. Detect protein targets with high precision and sensitivity from only 1 �L sample. Should be compatible with serum, plasma, and other type of biological sample starting material. Must be able to be used on the Fluidigm� BioMark� system and The Juno� system. Results reported in standard concentration units(pg/mL) or NPX units Minimum Essential Characteristics (MEC) for Olink Proteomics: Olink� Target 96 Neurology Reagent Kit (95801) High throughput analysis of at least 92 protein biomarkers across 96 samples simultaneously with no loss in data quality. Detect biomarkers both established and exploratory. Access to list of all protein biomarkers via Olink�s biomarker and panel library. Reagents utilize Proximity Extension Assay technology to conserve data purity. Detect protein targets with high precision and sensitivity from only 1 �L sample. Should be compatible with serum, plasma, and other type of biological sample starting material. Must be able to be used on the Fluidigm� BioMark� system and The Juno� system. Results reported in standard concentration units(pg/mL) or NPX units Minimum Essential Characteristics (MEC) for Olink Proteomics: Olink� Target 48 Cytokine Reagent Kit (93200) High throughput analysis of at least 45 protein biomarkers across 48 samples simultaneously with no loss in data quality. Detect biomarkers both established and exploratory. Access to list of all protein biomarkers via Olink�s biomarker and panel library. Reagents utilize Proximity Extension Assay technology to conserve data purity. Detect protein targets with high precision and sensitivity from only 1 �L sample. Should be compatible with serum, plasma, and other type of biological sample starting material. Must be able to be used on the Fluidigm� BioMark� system and The Juno� system. Results reported in standard concentration units(pg/mL) or NPX units
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/d8d625a7c2824bb897d22936da3ce9d6/view)
- Place of Performance
- Address: Silver Spring, MD 20901, USA
- Zip Code: 20901
- Country: USA
- Zip Code: 20901
- Record
- SN06573439-F 20230127/230125230111 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |