SPECIAL NOTICE
Y -- W912DR23B0007 - Pre-Qualification of Sources Notice for the Recycling Collection Center - Fort Meade, MD
- Notice Date
- 2/8/2023 11:40:06 AM
- Notice Type
- Special Notice
- NAICS
- 236220
— Commercial and Institutional Building Construction
- Contracting Office
- W2SD ENDIST BALTIMORE BALTIMORE MD 21201-2526 USA
- ZIP Code
- 21201-2526
- Solicitation Number
- W912DR23B0007
- Response Due
- 11/29/2022 11:00:00 AM
- Archive Date
- 03/31/2023
- Point of Contact
- ERICKA COLLINS, Patricia Morrow
- E-Mail Address
-
ericka.t.collins@usace.army.mil, patricia.l.morrow@usace.army.mil
(ericka.t.collins@usace.army.mil, patricia.l.morrow@usace.army.mil)
- Description
- **CLARIFICATION: RFI's were due 18NOV and pre-qualification submissions are due 29NOV. All other terms and conditions remain the same.** Amendment 0001 - The construction magnitude was changed from $5M-10M to $1M-5M. In addition, the submission through PIEE for this pre-qualification notice was removed and only email will be used. The Amendment 0001 attachment is listed below. All other terms and conditions will remain the same. PLEASE SEE ATTACHED REQUEST FOR PREQUALIFICATION INFORMATION AND�INSTRUCTIONS. INTERESTED CONTRACTORS SHALL RESPOND IN�ACCORDANCE WITH THE ATTACHED INSTRUCTIONS. This is the Prequalification of Sources notice for the Recycling Collection Center at Fort Meade, MD.�Sources will be prequalified in accordance with DFARS 236.272. Under these�procedures, Offerors will be required to submit information addressing�capabilities and other factors identified in the prequalification criteria. The�Government will evaluate the prequalification information and determine a�list of qualified Offerors to which the Invitation for Bid (IFB), including�plans and specifications, will be sent. The contract is for the construction of an 8,200 GSF recycling center with 2,856 SY concrete pads in support of NSA refuse operations.�The supporting facilities include site preparation, infrastructure improvements, utility services, perimeter security measures, infrastructure for the telecommunication and the physical security system.� The site preparation will include standard clearing, grubbing, cut, fill, grading, storm water management systems, surface parking upgrades, and landscaping.�� The new facility shall include a processing floor, loading dock, storage area, and an administrative area.� The administrative area shall be fully conditioned and comprised of two desk stations, a large central break area for staff which will double as meeting space, lockers, a single shower, and single latrine, janitor closet, three utility rooms for communications, mechanical, and electrical and direct access to the processing floor and outside.� The facility shall be required to comply with user-defined security requirements, and force protection measures that will include fences, vehicle barriers, an electronic security system, card readers for the office portion of the building, and a CCTV camera. The facility shall also meet the requirements of the Architectural Barriers Act (ABA) Standards.�In�accordance with DFARS 236.204, the magnitude of construction is between�$1,000,000 and $5,000,000. Note: This requirement was previously listed using the solicitation number W912DR22R0053; however, since we are in FY23 the solicitation number is now W912DR23B0007.�
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/d68b5b26d6a6414da40bd7e3c3acd825/view)
- Place of Performance
- Address: USA
- Country: USA
- Country: USA
- Record
- SN06585468-F 20230210/230208230105 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |