SOLICITATION NOTICE
44 -- BED BUG OVEN - TOP VAMC
- Notice Date
- 3/1/2023 7:59:41 AM
- Notice Type
- Presolicitation
- NAICS
- 333994
— Industrial Process Furnace and Oven Manufacturing
- Contracting Office
- 255-NETWORK CONTRACT OFFICE 15 (36C255) LEAVENWORTH KS 66048 USA
- ZIP Code
- 66048
- Solicitation Number
- 36C25523Q0228
- Response Due
- 3/6/2023 10:00:00 AM
- Archive Date
- 03/20/2023
- Point of Contact
- Ashley Schmitt, Contracting Specialist, Phone: 913-946-1974
- E-Mail Address
-
ashley.schmitt@va.gov
(ashley.schmitt@va.gov)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Awardee
- null
- Description
- Statement of Work Bed Bug Oven Topeka VA Medical Center Bed bug treatment oven to kill 100% of bed bugs in all life stages, including eggs, nymphs and adults: Inside self-contained heating cabinet needs to be at least 70""H x 34""W x 22""D. Unit shall be mounted on casters. Allow the preprogramming of digital controller with a low temperature (120 degrees) and high temperature (150 degrees) cut off limits and a set point of 130 degrees. Bed Bug Oven needs to be designed to kill bedbugs using a heat treatment cycle of 130°F ± 5°F for a period of 30 minutes. Oven will need to be designed for a single phase, 120/24OVAC, 20A power feed. One 240 VAC, 1700W resistive heater is protected by a two pole 10A circuit breaker and two safety thermal switches wired in series. The temperature of the oven needs to be controlled by a temperature controller in the PLC with a preset temperature set point of 130°F and uses ON/OFF control to reach and maintain the set point. The feedback transducer to the controller needs to be a Type K thermocouple. The temperature controller needs to be controlled by the airflow temperature of the oven and set to a maximum temperature of 170°F. The fan and control electronics need to be powered by 120 VAC through a 1A and 2A circuit breaker, respectively. The fan needs to be configured to remain on after the cycle is complete and turn off when the door is opened, or the ""STOP/RESET"" pushbutton is pressed. The cycle timing of the heat treatment cycle needs to be initiated when the probe temperature of the items being treated reaches and maintains 130°F. When the heat treatment cycle is complete the resistive heaters need to shut off and have a completion indicator. A spare parts package to consist of 1 each: heater element, thermocouple, over-temperature switch, solid state relay and fan unit.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/3e9377d5b67a4a81869b8057ad48a761/view)
- Place of Performance
- Address: Colmery-O'Neil VA Medical Center 2200 Gage Blvd, Topeka, KS 66622, USA
- Zip Code: 66622
- Country: USA
- Zip Code: 66622
- Record
- SN06605465-F 20230303/230301230106 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |