SOURCES SOUGHT
65 -- Dental Milling Machine CS: Maureen Sundstrom
- Notice Date
- 3/3/2023 10:30:03 AM
- Notice Type
- Sources Sought
- NAICS
- 339114
— Dental Equipment and Supplies Manufacturing
- Contracting Office
- 260-NETWORK CONTRACT OFFICE 20 (36C260) VANCOUVER WA 98662 USA
- ZIP Code
- 98662
- Solicitation Number
- 36C26023Q0356
- Response Due
- 3/13/2023 3:00:00 PM
- Archive Date
- 04/12/2023
- Point of Contact
- Maureen Sundstrom, Contract Specialist, Phone: 253-888-4935
- E-Mail Address
-
Maureen.Sundstrom@va.gov
(Maureen.Sundstrom@va.gov)
- Awardee
- null
- Description
- Sources Sought Notice Sources Sought Notice Sources Sought Notice *= Required Field Sources Sought Notice THIS IS A SOURCES SOUGHT NOTICE ONLY. The purpose of this Sources Sought Notice is to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement, and to gain knowledge of potential qualified Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), other Small Businesses interested and capable of providing items requested, as well as any large business interested and capable. This REQUEST FOR INFORMATION/SOURCES SOUGHT NOTICE in support of the Alaska VA Healthcare System, is for market research purposes only to determine the availability of potential vendors with capabilities to provide the requirement described below. This Request for Information/Sources Sought Notice is for information and planning purposes only and is not to be construed as a commitment by the Government. The Government will not pay for information solicited. Respondents will not be notified of the results of the evaluation. Results will be used to determine set-aside. The intended contract is a firm-fixed price supply purchase. Potential contractors shall provide, at a minimum, the following information: 1) Company name, address, and point of contact, phone number, e-mail address, and SAM.gov UEI number/code. 2) Anticipated North American Industry Classification System (NAICS) code is 339114. The largest a firm can be and still qualify as a small business for Federal Government programs is no more than 750 Employees. Please indicate whether you are a Small Business, SDVOSB, VOSB, Small Business Manufacturer, Other Small Business, or Large Business, and whether you are the manufacturer of the item listed below. 3) The Government is not obligated to nor will it pay for or reimburse any costs associated with responding to this sources sought notice. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued. Notice to Potential Offerors: All Offerors who provide goods or services to the United States Federal Government must be registered in the System Award Management (SAM located on the web at www.sam.gov). It is desirable that any Offeror to have completed their business Online Representations and Certifications Application in the System for Award Management (SAM). 4) Any Service-Disabled Veteran Owned Businesses or Veteran Owned Businesses who respond to a solicitation on this project must be registered with the Department of Veterans Affairs Center for Veterans Enterprise VetBiz Registry located at http://vip.vetbiz.gov. 5) If not a manufacturer, only authorized representatives/providers/distributors of the manufacturer will be considered. Equipment must be new, no used or refurbished equipment accepted. Please provide a proof of authorized dealer or reseller letter from manufacturer. 6) If you are the manufacturer, do you have any designated or authorized distributors? If so, please provide their name, telephone, point of contact and size status (if available). 7) This is a brand name only requirement. Please identify manufacturer name (OEM) and manufacturer part number, as well as any warranty information. Please provide a courtesy quote in response to this request to evaluate price reasonableness for any set-aside determination. Please provide the country of origin. It is the intent of the VA to use the information gathered for market research purposes only. If a formal solicitation is released, it will be posted via the Contracting Opportunities website located at beta.sam.gov. or GSA eBuy. DESCRIPTION OF THE REQUIREMENT: The Department of Veterans Affairs is looking to obtain information on vendors who can provide the products as outlined below. This is an Unrestricted/Open Market Brand Name Only Request for Information/Sources Sought Notice. Delivery address: Alaska VA Healthcare System AVAHS Warehouse 5955 Zeamer Ave JBER, AK, 99506 Items: Chairside Solutions: 1 6726561 CEREC Primemill US 1 6482850 SpeedFire Over 1 100006252 Suction Unit (Dry Milling) 120 VAC 1 6286095 CEREC Sustainment Extension years 4 1 6286095CEREC Sustainment Extension years 5 1 6286228 CEREC Sustainment Milling Unit Only Labside Solutions: 1 100003966 INEOS X5 Package (Scanner, PC + Monitor) (6324649+6042548) 1 6149640 INLAB/INEOS On-Site Training (CONT USA) 1 100004344 CEREC Sustainment INEOS Scanner 3 year Warranty Salient Characteristics: Salient Characteristics Dental Milling Unit Description: Device used for computer-aided production of dental restorations, abutments, parts of abutments and drilling templates for implant placement. Must be compatible with CEREC SW software. Specifications: Compatible with CEREC SW 5.1.1 and higher versions Digital feed control with force monitoring Process-controlled tool drives Grinding tools Diamond 1.4 CS (white) Diamond 1.2 CS (white) Diamond 1.0 CS (white) Diamond 0.6 CS (white) Milling tools (wet and dry milling) Bur 2.5 ZrO2 CS (Yellow) Bur 2.5 PMMA CS (Red) Bur 1.0 CS (Black) Bur 0.5 CS (Black) Electrical: Nominal mains voltage 100 V 240 V Nominal mains frequency 50/60 Hz Nominal current 2.1 4.2 A Nominal power output 400 VA Permissible mains voltage fluctuations ±10% of nominal voltage Protection class I device Overvoltage category II Ambient conditions For indoor use Pollution degree 2 Air pressure: 700 hPa 1060 hPa Operating altitude: 3000 m Temperature range 5°C to 40°C 41°F to 104°F Humidity range 80% rel. up to 31°C (87.8°F) decreasing to 50% rel. up to 40°C (104°F) Operating mode: Continuous operation Radio equipment frequency band: 13,553 MHz 13,567 MHz Max. transmission power < 200 mW Dimensions: (WxHxD) in mm 729 x 454 x 465 Approx. weight 46 kg 8.2.3 Controller board 3x 2-axis stepping motor controller with microstepping 4 DC motor controllers with integrated speed and current control and force monitoring Ports: 1 Ethernet, 2 USB, 1 USB B, suction Salient Characteristics Dental Sintering Furnace Description: Induction-based sintering furnace that heats up fine-grained ceramic or metallic materials to create crowns. Heats up material below the melting point of the materials to maintain the shape of the crown. Must be compatible with the CEREC SW crown-modeling software. Components: Furnace chamber with bottom and top door insulation Switches for on/off and main fuses Control panel with communication interface that displays: Temperature of the furnace chamber Settings Overview of received jobs, ability to select jobs Field for oven status information Information menu: Machine name Serial number Furnace firmware User app MAC address Calibration date Ethernet port Two USB ports Specifications: Ability to be network-configured via a WLAN or LAN connection Environmental: Setup location: Indoors in dry area Operating altitude: 2000 m above sea level Temperature range: 5°C to 35°C (41°F to 95°F) Relative humidity max. 80% Pollution degree: 2 Maximum sintering temperature: 1600°C (2912°F) Dimensions and weight: Dimensions of unit (W x H x D in mm): 250 x 425 x 425 Dimensions of packaged unit (W x H x D in mm): 400 x 600 x 500 Furnace chamber: Diameter 38 mm x 20 mm height Approx. weight without packaging: 21 kg Approx. weight including packaging: 30 kg Electrical: Rated line voltage: AC 100V - 240V Rated power frequency: 50/60Hz Admissible line voltage fluctuations: ±10% of nominal voltage Power consumption: max. 1200 W Interfaces: 2x USB 2.0 1x LAN (RJ45) WLAN (optional via WLAN USB dongle) Protection Class I device Approximate required processing times: Approximate required compatible materials: Salient Characteristics inEOS X5 : Scanning Technology Blue Light optical triangulation Canning method(s) Automatic, Manual and/or Rotational Robotics Inside Axes 5 Multi-die Scanning Up to 4 individual dies per scan Triple Scanning capacity Articulator Integration Smart Scanning Technology Field of View per Scan - -30mm X 40mm Software Included InLab CAD Software and Sirona Connect Software If your business is interested and capable, please send the capability statement outlined above, and a courtesy market research quote to Maureen.Sundstrom@va.gov by 3:00pm PST on March 13, 2023. NO PHONE CALLS, PLEASE. Again, this is not a request for quote, and no solicitation is available at this time.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/3bd1f424bc43486ea906f7d992517754/view)
- Place of Performance
- Address: Alaska VA Healthcare System AVAHS Warehouse 5955 Zeamer Ave, JBER, AK 99506, USA
- Zip Code: 99506
- Country: USA
- Zip Code: 99506
- Record
- SN06608602-F 20230305/230304211931 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |