Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF MARCH 10, 2023 SAM #7773
SOLICITATION NOTICE

M -- Operation & Maintenance of the Quinault Wastewater Treatment System

Notice Date
3/8/2023 10:07:57 AM
 
Notice Type
Presolicitation
 
NAICS
221320 — Sewage Treatment Facilities
 
Contracting Office
USDA-FS, CSA NORTHWEST 2 Portland OR 972042829 USA
 
ZIP Code
972042829
 
Solicitation Number
1240BD23Q0047
 
Response Due
3/23/2023 12:00:00 PM
 
Point of Contact
A Kay Steffey, Phone: 2084844622
 
E-Mail Address
arlene.steffey@usda.gov
(arlene.steffey@usda.gov)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
This is the pre-solicitation notice for the forthcoming solicitation and attachments, which are expected to be posted on or around 24 MAR 2023.� The scope of the requirement is to perform The Contractor shall perform operation and maintenance (O&M) of the Quinault Sewage Treatment Plant (QSTP), which consists of the Lake Quinault Wastewater Treatment Plant (WWTP); two primary influent pumping stations; four secondary influent grinder pump stations; the associated influent collection piping; and five drain fields including the distribution lines, located along South Shore Road of Lake Quinault. O&M includes normal maintenance tasks, periodic major maintenance tasks, and the disposal of sludge from the WWTP. The Procurement Method will be Contracting by Negotiation. The NAICS Code for this procurement is 221320 with a size standard of $25.5 Million. This is a SMALL BUSINESS SET-ASIDE acquisition.� The USDA Forest Service intends to solicit and award a single-award standalone options contract with a base ordering period of 12 months, and optional ordering periods of 48-months. If the Government does not award a follow-on contract in time, the Government may require the Contractor to continue performance for an additional period up to six months under the Option to Extend Services clause.� The Geographic scope is the NW Washington.� The anticipated award date is June 2023. This contract will replace a contract for similar services awarded in 2017. Statement of Work: This solicitation and any resulting contract are for performance of the following�services: C1.1. The Contractor shall perform operation and maintenance (O&M) of the�Quinault Sewage Treatment Plant (QSTP), which consists of the Lake Quinault�Wastewater Treatment Plant (WWTP); two primary influent pumping stations; four secondary influent grinder pump stations; the associated influent collection piping; and five drain fields including the distribution lines, located along South Shore Road of Lake Quinault. O&M includes normal maintenance tasks, periodic major maintenance tasks, and the disposal of sludge from the WWTP. C1.2. Contractor shall perform emergency repair and provide callback services on the systems listed above; and� C1.3. Contractor shall perform testing and monitoring of the Quinault�Wastewater Sewage System which includes sampling, testing, and reporting as�outlined in the System Operation Manual, Lake Quinault Work Station�Wastewater Treatment Facility. Services shall be performed, as needed, seven (7) days per week for the contract�period. The Forest Service estimates operation and maintenance of this facility�requires 60 operator hours per week. An operator shall be on site at least two�(2) hours per day. Contractor shall furnish all labor, materials, supplies, supervision, transportation,�small tools, equipment, incidentals and services, unless otherwise listed as�Government-furnished, necessary for the day-to-day operation and maintenance�(O&M) of the Quinault Wastewater Sewage System in accordance with the�Washington State, Department of Health Annual Operating Permit and the System�Operation Manual, Lake Quinault Work Station Wastewater Treatment Facility. C-2 Description and Location C2.1. Location The facility is located in Quinault, Washington, along the South Shore Road of Lake�Quinault, Grays Harbor County, Washington. Lake Quinault is approximately 47 miles�north of Aberdeen/Hoquiam, Washington, on US Highway 101. The Forest Service Quinault Work Station is on South Shore Road, 1.5 miles East of Hwy. 101, next to the�Quinault Lodge. The WWTP is � mile up the hill from the Quinault Work Station.� C2.2. Description ? General Plant Description Influent enters the WWTP from Pump Station No. 1 through the mechanical fine�screen, which removes large debris. Influent then enters the equalization tanks�where it is mixed with decanted liquor from the sludge storage tank. Influent then�enters the gravity manhole and is mixed with liquor from the membrane filtration�tanks. The influent is then split and sent to the membrane filtration tanks for�processing. Processed material goes to the effluent tank for distribution to the drain�fields. Some material from the membrane filtration tanks feeds back to the�equalization tanks or gravity manhole and to the sludge tank. Flow to the WWTP fluctuates significantly both diurnally and seasonally.��Seasonally, the flow to the plant will fluctuate from 5,000� gallons per day (gpd), or�less during the winter months, to 60,000 gpd on peak summer days. Usage comes�from the Quinault Lodge, two Forest Service campgrounds and a trailhead parking�area, several intermittently used homes, and the Quinault Work Station. Use varies�significantly throughout the year. The Primary Operator is responsible for plant�adjustments to maintain efficient operation of the plant. Automatic and manual�monitoring assists the plant operators in maintaining efficient plant operation. A process schematic and hydraulic profile of the plant is attached in Section J of this�contract for clarification purposes. It is intended to illustrate the plant only and is�not intended to be a detailed representation of the plant process. Detailed�information can be found in the System Operation Manual, Lake Quinault Work�Station Wastewater Treatment Facility, which is available for physical�inspection at the WWTP and at the Supervisor�s Office (1835 Black Lake Blvd.SW, Olympia, WA 98512). These are the only two physical locations where�copies of the manuals are kept. Critical systems within the plant have been duplexed for redundancy to allow repairs�to be made without shutting down the plant. In addition, the controls have been�designed to allow human control of critical systems in the event of a Programmable�Logic Computer (PLC) failure. The WWTP, primary pump station No. 1 and pump�station No. 2 have backup generators and transfer switches to maintain power during�outages. Other pump stations will accept manually connected generators. The wastewater treatment plant was originally constructed in the 1970s and was�upgraded to a Membrane Bio-Reactor (MBR) facility that utilizes a membrane�filtration package manufactured by Zenon Corporation in 2006. The designed flow�rates are 24,000 gpd average annual flow, 40,000 maximum monthly flows, 80,000�gpd peak day flows, and 360,000 gpd peak instantaneous flow. This plant is operated under a LOSS Annual Operating Permit issued by the�Washington State Department of Health (WA DOH) (Permit No. GHB009). The�permit mandates effluent standards. The permit identifies the plant type as a Membrane Bio-Reactor. The Primary Operator in charge of day-to-day operations�shall be a Group II operator. At a minimum a Secondary Operator certified as�Group I shall be in charge during all regularly scheduled shifts. The Primary�Operator needs to be available to assist the Secondary Operator in a timely manner�to meet permit requirements put forth by DOH. C-3 Government-Furnished Property (GFP) The Government will provide the following item(s) of Government property to the�Contractor for use in the performance of this contract. This property shall be used�and maintained by the Contractor in accordance with the provisions of the�""Government Property"" FAR clause contained elsewhere in the contract.� C3.1. General Description a. Quinault Wastewater Treatment Plant;� b. Control panels, with mechanical and Operation & Maintenance manuals; c. Spare Parts as listed on the �Spare Parts List� spreadsheet, maintained by the Primary Operator, stored onsite at the Treatment Plant; in building #2507 on the Quinault Work Station ; or in the Quinault Office Building, in a locked room designated for �QSTP Storage�; d. Laboratory and other equipment including, but not limited to: 1. Dissolved Oxygen Probe Service Kit: YSI DY 834, or equal; 2. Dissolved Oxygen Meter: YSI model 50B, or equal; 3. Dissolved Oxygen Probe: YSI model DY-833; or equal; 4. Analytical Balance: Cole Parmer model L-11402-00, or equal; 5. Portable pH Meter; 6. Book Standard Method for the Examination of Water and Wastewater,�18th Edition; 7. Graduated Cylinder 500 ml (2 required) Hach, or equal; 8. Thermometer: -30 to 120�F with 1�F increments. VWR 61011-022; 9. Microscope: Reichert L151 MPD, or approved equal; 10. Refrigerator for sample storage: VWR Model R406G, or approved equal; 11. Refrigerator for food storage; 12. Evaporating Dishes: 120 ml, pack of 6, VWR 25310-110, or equal; and 13. Drying Oven: Stabil-Therm Model No OV12A, or approved equal. 14. Fluke Meter and Accessory Kit 15. Lawn Mower 16. Weed Eater 17. Leaf Blower 18. Pressure Washer 19. Portable 250-piece tool kit C3.2. Government-Furnished Expendable Items The Government will not furnish expendable items, the replacement of these�items will be the responsibility of the Contractor. a. Fuel for Forest Service owned equipment, a government project card will�be provided to purchase diesel and gas for Forest Service owned�equipment: generators, mower, weed eater, leaf blower and pressure�washer. b. Electrical panel and Mechanical system parts. These parts shall be stored�at the WWTP or in the designated locked room in the Quinault Forest�Service Office. C3.3. Government-Furnished Property (GFP) and Parts Inventories a. Equipment Condition Inventory� The Contractor and Contracting Officer�s Representative (COR) will jointly�conduct an inventory of Government-furnished property and a condition survey�of all major system components. General condition of individual pieces shall�be agreed upon by the COR and the Contractor in writing. During the course of the contract, the contractor shall be responsible for�maintaining an accurate record of all equipment inventoried. The record shall�include description, dates of repair work, replacement, maintenance, name of�party doing the repair or replacement, and costs.� b. Spare Parts and Materials Inventory Parts for routine repairs, all related lab testing equipment, tools and expendable items shall be inventoried by the COR and Contractor.� The Contractor shall complete the documentation for this inventory. The COR and Contractor shall also establish a list of parts and materials that are�to be maintained on hand for normal operation and maintenance. The contractor�shall prepare this list for documentation purposes and present it to the COR for�approval. This listing shall include item description and quantities and will be�used in conjunction with the inventory to determine a ""maintenance needs list"". The Contractor shall be responsible for maintaining and updating inventories. The Contractor shall produce a computerized spreadsheet preferred format is�Microsoft Excel of inventories for presentation to the COR in electronic format. The Contractor shall maintain a spare parts inventory adequate to bring the�system back into operation within six (6) hours after shutdown due to failure. The Contractor shall maintain accountability and use records of all spare parts in�inventory, and upon completion of contract, promptly transfer spare parts to the�Government. C3.4. Emergency Response The Contractor shall take action to continue operation of the WWTP during power�outages meeting permit. Items acquired and used by the Contractor during storm�events or other emergencies, to continue operation of the WWTP will be�reimbursed by the Government upon receipt of supporting documentation. C.3.5 Government Furnished Services The Forest Service will pay for and provide the following services:� a. Annual WA DOH Operating Permit b. Electrical troubleshooting and repair C-4 Contractor Obligations The contractor shall furnish all labor, supervision, transportation, small tools,�equipment, expendable items and incidentals listed below, unless otherwise listed�as Government-furnished, necessary for the day-to-day operation and maintenance (O&M) of the WWTP in accordance with the Washington State Department of�Health Permit and the System Operation Manual, Lake Quinault Work Station�Wastewater Treatment Facility. The Contractor is responsible for the coordination, removal, and disposal of the�sludge. The sludge tank shall be periodically pumped and biosolids waste hauled�off-site to a disposal site by a licensed service provider The Contractor shall provide a vehicle which is capable of transporting the backup�generators when needed during power outages. This vehicle shall also have a DOT�approved portable diesel tank with pump secured in the bed of the vehicle. The�vehicle shall be less than 10 years old and in good working order at all times. The Contractor shall ensure that all personnel having direct unescorted access to the�WWTP comply with 48 CFR CHAPTER 1, 52.204-9. The Contractor shall create and maintain an inventory system to keep items in�stock, determine cost effective re-stocking levels, and allow adequate time for resupply. C4.1. Contractor-Furnished Expendable Items The Contractor will furnish the initial supply of the following expendable items�and replace these and other items as needed: a. Lab glassware b. Funnel filters c. Filter paper d. Disposable Lab glassware e. Lab chemicals f. Paper towels g. Soaps and cleaners h. Oils and greases i. Oil filters j. Poly-mesh bags for grit k. Sodium Hypochlorite l. Sodium Hydroxide m. Light bulbs C.4.2 Contractor Furnished Services The Contractor will provide the following services: a. Sludge removal and disposal. b. Laboratory analysis of monthly and quarterly sample meeting WA DOH�permit requirements C-5 Definitions C5.1 Wastewater System All sewage main collection lines and appurtenances (gravity and pressure,�manholes, pump stations); treatment plant (including treatment building, pumps,�motors, process controls and electrical schematics); all system controls�(including remote annunciator and pump station controls, lightning arrestors,�and alarm system); effluent lines and drain fields; sewer pumps; O&M manuals;�lab equipment; and emergency power generators. C5.2 Equipment All system mechanical and electrical components used for both normal and�emergency operation, including, but not limited to: lab/office appliances;�sampling equipment; switches; motors; pumps; valves; thermostats; heat tape;�samplers; control panels; and telecommunication equipment; with the necessary�tools and supplies for operation and maintenance of the equipment. C5.3 Expendable Items Items that are consumed due to the routine work process called for in the contract.� C5.4 Routine Operation and Maintenance Time/Proposed Work Schedule Routine operation and maintenance shall be conducted seven (7) days per week.�This time will be used for performing routine operation and maintenance�functions described in Section C. The contractor shall present their proposed normal work schedule to the COR�for review and approval. The contractor's schedule shall be such as to allow for�coordination of activities around heavy use periods of the day as well as for�continued operation of the plant in compliance with the permit requirements. The contractor shall spend a minimum of two hours per day on site. Additional�time may be needed to allow for delivery of samples to the certified lab, or�picking up spare parts or equipment.� C5.5 Routine Repair Routine Repair includes the following: trouble shooting cause of failure; hand�excavation to repair sewer lines; unclogging lines without mechanized line�cleaning equipment; equipment repair within the capabilities of the spare part�inventory; and assisting, when needed, with repairs performed by the�Government, or outside sources. C5.6 Repair Other Than Routine If troubleshooting and/or repair require equipment and/or repair parts outside�the scope of routine repair, Contractor shall notify COR of findings, including�an estimate of time, services, and supplies needed for repair. With CO written�approval, Contractor shall proceed with repair on an approved schedule.� C5.7 Responsible Charge Responsible charge is defined as active, daily, on-site representation and�performance of wastewater system and equipment operations, including routine�operations and maintenance activities. This definition will be applied to the�description of Primary or Secondary operator. The Primary Operator will be�considered the ""operator of record."" Secondary Operator at a minimum shall be�in charge during all regularly scheduled shifts. C5.8 Down Time Down time is the period when the system is not operable due to failure of a�significant component, or due to circumstances beyond the Contractor's control.�� C-6 Personnel Qualifications and Responsibilities C6.1. Operator � General Operator responsibilities (Primary and Secondary Operator) include the�following: a. Implement all provisions in the System Operation Manual, Lake�Quinault Work Station Wastewater Treatment Facility. This includes but�is not limited to: equipment maintenance scheduled and completed as�recommended by individual equipment manufacturers, logs kept and�electronically transmitted to COR on a monthly basis. b. The Contractor shall develop standard operational procedures augmenting information in the System Operation Manual, Lake Quinault�Work Station Wastewater Treatment Facility that may be used later to�update these manuals. Present these written standard operational�procedures to the COR for review and approval within one month of�determination. Operate the WWTP as the manual directs and, if proper�results are not obtained, inform the COR and Contracting Officer. c. Maintain WWTP efficiency, throughout all daily and annual flow�fluctuations. d. Keep working areas clean, orderly, and safe. e. The WWTP is in a highly visible location. The contractor shall maintain�good relations with the public. There may be times when WWTP tours�will be requested by the COR. During these tours, the contractor shall�receive visitors courteously. Show the WWTP with professionalism,�sharing accurate information. f. The contractor may be requested to provide work direction and any�necessary on-the-job training to Government personnel and/or seasonal�employees. This is expected to be infrequent and limited in scope. The�COR will coordinate such training in advance with the contractor.� g. Establish a preventive maintenance program and present the written�description of this program to the Contracting Officer for review and�approval within 30 days of contract award. h. Maintain accurate operating records. Records will show trends and causes�and provide information that must be reported to the DOH within operating�permit requirement timelines. Detailed daily logs are to show a picture of�tests made and actions taken which bear upon WWTP efficiency. i. Communicate with the COR regarding any necessary updates to the�System Operation Manual, Lake Quinault Work Station Wastewater�Treatment Facility. j. Make all necessary negotiated updates to the System Operation Manual,�Lake Quinault Work Station Wastewater Treatment Facility both�physically on the hard copy manual kept at the WWTP and electronically�in the Word, Excel, AutoCAD, etc. files, provided within one month of�determination. k. Maintain communications with the COR at a minimum of monthly and�as needed. l. Operate in a cost effective and efficient manner. m. Keep informed about current operation practices for similar treatment�WWTPs. n. Read and understand the System Operation Manual, Lake Quinault Work Station Wastewater Treatment Facility manual within 3 months of being�assigned to work at the WWTP. o. When the Primary Operator is unavailable for any length of time, it is�critical that a Backup Primary Operator is provided as described below. The Backup Primary Operator shall provide the same services and shall�have the same responsibilities as the Primary Operator. The Backup�Primary Operator shall meet the same education, rating, and work experience minimums as listed for a Group II operator. C6.2 Qualifications and Certification � General A wastewater system Primary Operator shall have a Group II certification, as�defined by Washington State Department of Ecology (WSDOE). The�wastewater system Primary Operator is required to be the responsible person in�charge of operating the WWTP. The wastewater system Primary Operator shall�have a minimum of two years of experience as the on-site responsible person in�charge, including day-to-day operations and maintenance, monitoring,�compliance testing, WWTP adjustment, and emergency response. The�wastewater system Primary Operator shall demonstrate knowledge and�experience in full WWTP operation; or equivalent experience and training which�demonstrates the ability to perform the above-described duties. A wastewater system Secondary Operator, with Group I certification as defined�by WSDOE, may perform the day-to-day operation of the WWTP. The�wastewater system Secondary Operator shall have experience in day-to-day�operations and maintenance,� monitoring, compliance testing, WWTP�adjustment, and emergency response. The wastewater system Secondary�Operator shall demonstrate knowledge and experience in full WWTP operation;�or equivalent experience and training which demonstrates the ability to perform�the above-described duties. C6.3 Training Programs The Contractor shall provide training required to maintain the qualifications of�the WWTP Primary Operator, the Secondary� Operator, and the Backup Primary�Operator. Qualifications are defined by WSDOE in their operator certification�requirements. C.7 BioPreferred Program Requirements The Contractor shall comply with Section 9002 of the Farm Security and Rural�Investment Act of 2002 (FSRIA), Executive Order� (EO) 13423, �Strengthening�Federal Environmental, Energy, and Transportation Management,� and the�Federal Acquisition Regulation to provide biobased products. The Contractor shall utilize products and material made from biobased materials�(e.g., biobased greases, biobased hydraulic fluids, biobased absorbents) to the�maximum extent possible without jeopardizing the intended end use or detracting�from the overall quality delivered to the end user. All supplies and materials shall�be of a type and quality that conform to applicable Federal specifications and�standards. All supplies and materials to be used in the performance of work�described herein are subject to the approval of the Contracting Officer�Representative (COR). The following is an example list of products that may be used in this contract for�operations and maintenance for which biobased products are available. The list is�not all inclusive. It is desirable that vendors be able to supply the greatest number�of biobased products listed meeting the health and environmental specifications. Hydraulic fluids Penetrating lubricants Concrete and asphalt release fluids Absorbents Diesel fuel additives Greases Dust suppressants 2-cycle engine oil Wood and concrete sealers Fertilizers Roof coatings Water tank coatings Adhesive and mastic removers Cleaners Sorbents Floor finish Floor stripper Composite panels Insulating foam Sealers Carpet Metalworking fluids Graffiti and grease removers Stain removers Degreasers De-icers Biobased products that are designated for preferred procurement under USDA�s�BioPreferred program must meet the required minimum biobased content as�stated in the USDA Final Rule available at www.biopreferred.gov. The�Contractor should provide data for their biobased products such as biobased�content. In addition to the biobased products designated by the U.S. Department of�Agriculture in the BioPreferred Program, the Contractor is encouraged to use�other biobased products. The Contractor shall submit with the initial proposal a complete list of biobased�products, indicating the name of the manufacturer, cost of each material, and the�intended use of each of the materials that are to be used in carrying out the�requirements of the contract. Additionally, the winning Contractor on each�anniversary date of the contract shall compile a complete list of biobased�products, including the information above, purchased to carry out the contract�requirements. The Contractor shall list volume to be used and total cost for each�individual product. This information will provided to the COR and will be used�for reporting purpose. The Contractor shall comply with the provision of FAR 52.223-1, Biobased�Product Certification and clause FAR 52.223-2, Affirmative Procurement of�Biobased Products Under Service and Construction Contracts.��Within thirty (30) days of contract award, the Contractor shall submit an�Operations and Maintenance Plan. This submittal shall be approved by the COR�in writing. The Contractor shall not commence work until this submittal is�approved by the COR in writing. The Plan must be reviewed and updated annually, and as required by the COR�and must contain and define the following elements: 1. The Contractor�s written policy stating its commitment to the use of�biobased products, employee health and safety, and sound environmental�management practices. 2. Detail on how the Contractor intends to keep abreast of the increasing�availability of biobased products and how any new or improved products�will be incorporated on an ongoing basis into contract performance. 3. Proposed biobased operations and maintenance products which must be�selected in accordance with the criteria included above. At a minimum, the�Plan must identify products by brand name for each of the product types. NOTE: A Contractor may propose more than one product within a product�category and/or propose a product or products addressing more than one�product category. The product guides which define standard operating procedures for�instructing staff in the proper use, storage, and disposal of biobased�products; proper maintenance of equipment; and other�procedures/instructions to accomplish work under this contract. The Contractor shall provide data on the quantity and dollar values of biobased�products used in this contract. The data will be submitted to the COR annually. A demonstration of proper use, an effective training program, and technical�assistance are essential to the success of the purchase and use of some biobased products that may function differently than a conventional product�
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/eae83fef8ea941a2bb7f3ef84b2abe58/view)
 
Place of Performance
Address: Quinault, WA, USA
Country: USA
 
Record
SN06611910-F 20230310/230309211940 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.