Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF MARCH 12, 2023 SAM #7775
SOURCES SOUGHT

W -- SPS Mobile Unit Rental - QTY = 2

Notice Date
3/10/2023 10:09:43 AM
 
Notice Type
Sources Sought
 
NAICS
532120 — Truck, Utility Trailer, and RV (Recreational Vehicle) Rental and Leasing
 
Contracting Office
248-NETWORK CONTRACT OFFICE 8 (36C248) TAMPA FL 33637 USA
 
ZIP Code
33637
 
Solicitation Number
36C24823Q0703
 
Response Due
3/15/2023 8:00:00 AM
 
Archive Date
04/14/2023
 
Point of Contact
Janice Fornaro, Contract Specialist, Phone: 727-398-9335
 
E-Mail Address
janice.fornaro@va.gov
(janice.fornaro@va.gov)
 
Awardee
null
 
Description
This is an RFI (Request for Information) for commercial items included in this notice. The Department of Veterans Affairs, C.W. Bill Young VA Healthcare System, Contracting Office, Bay Pines, FL 33744 has a need for BRAND NAME or EQUAL MSPSU (Mobile Sterile Processing Services Units, Quantity = two (2)) mobile trailers referenced in the below Statement of Need. The RFI # is 36C24823Q0703. All interested vendors shall provide a response to Janice Fornaro by 15 March 2023 at 11 PM EST via e-mail to: janice.fornaro@va.gov. The Subject Line of the response e-mail shall include RFI 36C24823Q0703 . DISCLAIMER: This RFI is issued solely for informational and planning purposes and does not constitute a solicitation. Responses to this notice are not offers and cannot be accepted by the Department of Veterans Affairs to form a binding contract. Respondents are solely responsible for all expenses associated with responding to this RFI. Statement of Need Bay Pines Healthcare System 10000 Bay Pines Blvd Bay Pines, FL 33744 (Steris Corp. Brand Name or Equal) Project Title: Mobile Sterile Processing Services Units (MSPSU) PROJECT DESCRIPTION: Bay Pines VA Healthcare System (BPVAHCS) is seeking to lease two Mobile Surgical Processing Services Units (MSPSU). The facility s Sterile Processing Services (SPS) will be closed for approximately 10 months for an HVAC renovation project. Using an MSPSU will allow the facility to continue performing decontamination, manual cleaning, and sterilization procedures during the renovation project. The MSPSUs at the main hospital at the Bay Pines VA Medical Center (one unit at building 100 and one unit at building 23). The units will be needed approximately beginning April 1, 2023. DESCRIPTION OF NEED: MSPSU: The selected vendor will deliver, set up, and certify two fully enclosed functioning Mobile Sterile Processing Services units that include: 3 Bay Decontamination Sink with Acu-sinQ Enzymatic Dosing System Two Vision Washers Electric Approximately 24 sets per hour. Caviwave Pro Pass Thru Window Four Prep and Pack Tables Two Steam Sterilizers Approximately 18 20 total sets per hour capacity Two (2) V-Pro Max VHP Low Temp Sterilizers RO/DI Water System (for final rinse on washers) Two Steam Generators ProConnect Response Center Hand wash sink with eye wash Water treatment system Sterile room HVAC system Continuous Air Pressure Monitoring Decontamination room Emergency Exit stairs and platform Power: The selected vendor shall be responsible for providing MSPSU that includes: Electrical Service: 480VAC, 3 phase, (2) 250 AMP Configuration: 4 wire (L1, L2, L3, G) Frequency: 60hz Shoreline Cable: (2) cables will be provided; facility end hard wired 100 if possible. Disconnects must be within 50 of the front/nose of the unit Request this be 100 if possible. Earth ground provided; installation per NEC Article 250 (1) single point female bayonet type located directly under the roadside power connection (1) 20 ground cable with (2) clamps The Facility will Provide: Emergency power Termination of wiring from the emergency power source to MSPSU connection Appropriate cable covers and fencing Hot Weather Package: The Facility will Provide: Electric Service: 480VAC, 3-Phase, 60hz 30 AMP breakers STERIS will supply HVAC pre-cooling unit including all ancillary components. Plumbing: The selected vendor will provide: 4-inch wastewater connection Functional validation of all sinks 1 ¼ inch connection (#5 Roadside Belly Box) External lines must be facility protected Minimum 40 psi dynamic at SPD The Facility will Provide: Potable cold water, minimum 25 GPM at 40-50 psi (dynamic) External piping from facility to MSPSU Insulation and heat tape to external pipe from facility to MSPSU connection Dedicated circuit for pipe heat tape Termination of heat tape to facility panel External drain piping from facility to MSPSU Water Testing: The selected vendor will provide water testing services and a monthly report showing compliance with AAMI standards and AAMI TIR34. Fire Alarm and Sprinkler System: The selected vendor will provide: Conventional analog fire alarm system with local audible visual, horn strobe alarm devices for occupant warning. 2 zones with detection and pull stations Sprinkler supply: 2-inch Victaulic coupling (rear of unit) Fire alarm remote dry contacts The Facility will Provide: Dedicated sprinkler supply 143 GPM at SPD Residual Pressure 46 psi minimum at SPD Termination wiring from trailer fire alarm dry contacts to facility Certification of system via third party Security Alarm: The selected vendor will supply: Intrusion alarm system on MSPSU exterior doors Exterior audible alarm at the trailer. Security alarm dry contacts The Facility will Provide: Termination wiring from MSPSU intrusion alarm dry contacts to facility Telephone and data: The selected vendor will supply: two unmanaged IT switches: 1 switch dedicated to trailer equipment 1 switch dedicated to Customer equipment The Facility will Provide: Managed switches Termination wiring from termination block Termination wiring from MSPSU data router to facility Functional validation of communications Integrated Medical Equipment: The selected vendor will supply and maintain: 3 Bay Decontamination Sink with Acu-sinQ Enzymatic Dosing System Two Vision Washers Electric Caviwave Pro Pass Thru Window Four Prep and Pack Tables Two Steam Sterilizers Approximately 18 20 total sets per hour capacity Two V-Pro Max VHP Low Temp Sterilizers RO/DI Water System (for final rinse on washers) Two Steam Generators ProConnect Response Center Heating and Cooling System: The selected vendor will supply: Nominal ¾ pipe(s) at front and rear of unit The Facility will Provide: The Facility will Provide: Connection and routing of ¾ condensate drains Unit Anchoring: The selected vendor will provide: 8) at 5,000 lb. tensile capacity (2 each per corner). (For wind rating. If in Seismic zone it is 10,000 LB. tensile capacity). Strapping and hardware attaching each trailer tie down ring to its corresponding ground anchor point The Facility will Provide: Anchor points to be located on the ground at 30 45 degrees from the unit tiedown points Education: Provide in-service education and support for facility staff on use of all trailer/equipment ADDITIONAL INFORMATION: Please provide: Capabilities of your system that are not listed above Floorplans, schematics and technical information All necessary unscheduled and preventative maintenance of equipment, per OEM standard, that is included with the unit Point of contact for service Cleaning instructions Include delivery and set-up as specified above Include pick-up at the end of the lease
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/1969a059883c487f9bc62c49dafed801/view)
 
Place of Performance
Address: C.W. Bill Young VA Healthcare Syste 10,000 Bay Pines Boulevard, Bay Pines, FL 33744, USA
Zip Code: 33744
Country: USA
 
Record
SN06615263-F 20230312/230310230108 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.