Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF MARCH 23, 2023 SAM #7786
SOURCES SOUGHT

99 -- Exhaust Stack Industry Chimney Inspection

Notice Date
3/21/2023 6:08:22 AM
 
Notice Type
Sources Sought
 
NAICS
926150 — Regulation, Licensing, and Inspection of Miscellaneous Commercial Sectors
 
Contracting Office
SRNS - DOE CONTRACTOR Aiken SC 29801 USA
 
ZIP Code
29801
 
Solicitation Number
SRNS32023EXHAUSTSTACKINSPECTION
 
Response Due
4/20/2023 2:00:00 PM
 
Point of Contact
Barbara McCarty, Phone: 8039526119
 
E-Mail Address
barbara.mccarty@srs.gov
(barbara.mccarty@srs.gov)
 
Description
****This is a REQUEST FOR INTEREST ONLY! This request does not constitute a request for proposal, request for quote, or invitation for bid. The intent of this request is to identify potential offerors for market research purposes only***** Savannah River Nuclear Solutions, LLC (SRNS), which manages and operates portions of the Savannah River Site (SRS) under a Department of Energy (DOE) prime contract, solicits expressions of interest from potential suppliers who have a strong background in Exhaust Stack and/or Industrial Chimney inspections. The SRS complex is located approximately 15 miles south of Aiken, South Carolina and is 310 contiguous square miles. Request for Information (RFI) Scope Summary: Provide an internal and external inspection of a 200� tall reinforced concrete stack exterior chimney and internal acid proof brick liner at an active nuclear facility. Inspection of a connecting structural steel breeching duct house and an adjacent 100� tall structural steel stair tower is also requested. The stack was built in 1954. Pictures nor drawing of the stack are not provided at this time. The diameter at the base of the 291-H stack is approximately 18� decreasing to approximately 12�-7� outer diameter at the top with approximately 12� thick walls at the base decreasing to approximately 6� thick walls at the top. The thickness of the acid proof brick lining is approximately 12� at the base extending to the 24�-4� elevation, approximately 8� thick from the 24�-4� elevation to the 149�-4� elevation, and approximately 4� thick from the 149�-4� elevation to the 199�-4� elevation. There are 3/8� diameter stainless steel threaded studs anchored into the exterior of the reinforced concrete stack at approximately 4� on center from the top of the stair tower to the top of the stack for inspection ladder purposes. There are no known studs on the interior of the reinforced concrete stack chimney or brick liner wall to attach ladders. Thickness measurements of the reinforced concrete stack wall are to be performed including coring into the reinforced concrete stack chimney and thickness measurements using nondestructive examination methods (e.g., GPR, ultrasonic tomography, etc.) Environmental working conditions include Airborne radiological contamination requiring the use of plastic suits, full-face respirators, and radiological monitoring of personnel exposure to radiation Airborne chemical vapors requiring the use of plastic suits and full-face respirators� Working in permit required confined spaces � A reduced airflow rate of 220,000 to 230,000 cfm and exit velocity of approximately 25 mph Possible performance of work on elevated platforms, ladders, and scaffolds requiring use of safety harnesses (rigging) Possible use of a crane to raise/lower personnel and equipment inside the stack Experienced Subcontractor personnel not already trained and qualified to work in accordance with the SRS safety and operational procedure requirements will be provided training by SRNS. The provision of a final inspection report with assessments of the condition of the structures and recommendations will be required.� Subcontractor shall be NQA-1 certified and subcontractor personnel shall be qualified/certified to provide visual inspection, NDE, and destructive examinations of the following: Reinforced concrete structures and concrete anchorages (ACI inspection standards) Masonry (brick) structures Steel structures, stainless steel components Weldments (ANSI/AISC, AWS CWI � crack detection only) Bolted connections (snug tight, hand tight) Coating systems (paint and galvanized coating failures) Coring/regrouting of reinforced concrete stack chimney Required Codes/Standards ACI 201.1R-08 Guide for Conducting a Visual Inspection of Concrete in Service ACI 207.3R-18 Practices for Evaluation of Concrete in Existing Massive Structures for Service Conditions ASTM C174-17 Standard Test Method for Measuring Thickness of Concrete Elements Using Drilled Concrete Cores ASTM C803-18 Standard Test Method for Penetration Resistance of Hardened Concrete ASTM C805-18 Standard Test Method for Rebound Number of Hardened Concrete ASNT SNT-TC-1A Personnel Qualification and Certification in Nondestructive Testing, 2020 Edition Research Council on Structural Connections (RCSC) Specification for Structural Joints Using High-Strength Bolts, August 1; 2014 Edition AWS D1.1/D1.1M Structural Welding Code�Steel, 24th Edition 2022 ANSI/AISC 360-22, Specification for Structural Steel Buildings ASME NQA-1 2008, Addenda 2009 5.4Quality Assurance Requirements for Nuclear Facility Applications A supplier's response to the RFI does not guarantee they will be selected to participate in the RFP. Suppliers responding to this RFI shall include evidence of the following: 1.� Overview of how the subcontractor intends to perform non-destructive and visual inspection on an active stack with similar specs. 2.� The Subcontractor shall submit examples of past performance of similar stack inspections.� For example, a report of an inspection that was previously completed. 3. Lead time required for mobilization and estimated inspection completion date. The preference is for completion before end of this fiscal year, Sep. 24, 2023.�� E-mail response addressing Items 1-3 above shall be submitted by 5:00 p.m. est. on 4/20/23 to Barbara McCarty at barbara.mccarty@srs.gov.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/bf57c8fe6bc14b48ad47a0deb0a688eb/view)
 
Place of Performance
Address: Aiken, SC 29808, USA
Zip Code: 29808
Country: USA
 
Record
SN06625919-F 20230323/230321230111 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.