Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF MARCH 24, 2023 SAM #7787
SOURCES SOUGHT

65 -- Chiropractic Tables

Notice Date
3/22/2023 7:00:56 AM
 
Notice Type
Sources Sought
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
244-NETWORK CONTRACT OFFICE 4 (36C244) PITTSBURGH PA 15215 USA
 
ZIP Code
15215
 
Solicitation Number
36C24423Q0623
 
Response Due
3/31/2023 9:00:00 AM
 
Archive Date
05/30/2023
 
Point of Contact
Ronald Kline, Contracting Officer, Phone: 412-822-3755
 
E-Mail Address
ronald.kline@va.gov
(ronald.kline@va.gov)
 
Awardee
null
 
Description
Automatic Manual Flexion Elevation Chiropractic Tables for VA Medical Center Butler, PA Purpose and Objectives: The intent of this Sources Sought Notice is to identify potential businesses, especially any Small Businesses, Service Disabled Veteran Owned Small Businesses (SDVOSB) or Veteran Owned Small Businesses (VOSB) offerors capable of providing Elite Automatic Manual Flexion Elevation Chiropractic Tables as listed in the below General Requirements utilizing NAICS Code 339112. Responses to this Sources Sought Notice shall be submitted via e-mail at ronald.kline@va.gov. Information provided will not be returned. All responses shall be in the English Language. Responses are due by 12:00 pm (EST) on Friday, March 31, 2023. GENERAL REQUIREMENTS: The Chiropractic tables will have the following requirements, as a Brand Name or Equal to the Elite Automatic Manual Flexion Elevation Chiropractic Tables The table must include the ability for multiple positions for patient comfort and clinician ergonomics. The table will have full range of motion and Flexion Distraction to treat spinal stenosis, neuroforaminal stenosis, facet arthrosis, lumbar disc herniation, and sciatica. The table must have a multi-direction cervical headpiece to promote the range of treatment strategies to manage conditions such as cervical facet arthrosis, cervical radiculopathy, and cervical disc herniation. The table design must allow for maximizing clinician ergonomics and safety in delivery of various manual procedures. This includes electronic elevation of the table. The table must permit the clinician to apply and deliver a variety of manual therapies with force parameters in a controlled manner compared to other designs thereby ensuring patient safety. SALIENT CHARACTERISTICS Table model: automatic/manual flex elevation Dimensions: 24 W x 78-84 L x 24-32 H Table Length: extendable range to include 78-84 Table Width: 24 Adjustable Height Elevation: 24 32 Motorized Elevation Weight Rating: 230 kg (500 lbs) Weight Rating on range of motion mechanisms in full retracted position: at least 500 lbs Cervical Headpiece Motions: Tilt, Elevation, Spread, Flexion, Traction, Lateral Flexion Cervical Drop: Forward motion Abdominal breakaway Upper and lower thoracic drop sections Unilateral , manual, adjustable tension on one side and drop cocking levers Pelvic drop section Dual manual, adjustable tension and drop cocking levers Axial Rotation Function: up to 22° of rotation Manual Flexion Function: 22°-25° degrees of flexion, capable of figure 8 range-of-motion, locked in flexion feature Manual Lateral Flexion Function: 20° right or left Distraction Function: up to 6 of distraction, Electric with dual foot switch control Auto Motorized Flexion Function: 22°-25° degrees Flexion Function convertible between manual and automatic control Extendable Ankle Rest Flexion strap clips for ankle and thoracic region for cuff restraints Flexion Handle: removable Control box for wall mount Digital control with flexion speed dial, toggle switch for timer or manual operation modes, duration display, and toggle on/off switch Fuse protected electrical system Electric Dual foot switch control Distraction Elevation Base: Powder Coated Steel Color: Gunmetal Upholstery Fabric: Leather Color: Khaki Table Weight Rating: at least 500 lbs User s manual 1-year commercial warranty DELIVERY Vendor to schedule delivery through a VA-approved contractor. Delivery must occur at the loading dock at VA Butler located at 353 North Duffy Road, Butler, PA 16001. The exact delivery date to be coordinated between the awarded vendor and the responsible staff at VA Butler VA Health Care System. Standard working hours at VA Butler s delivery dock are Monday-Friday, 7:30 a.m. to 4:00 p.m. This RFI will be conducted in accordance with Federal Acquisition Regulation (FAR) Part 13. Telephone responses will not be accepted. Responses must be received via e-mail to Ronald.kline@va.gov no later than, 12:00 PM Eastern Standard Time (EST) on Tuesday, March 21, 2023. This notice will help the VA in determining available potential sources only. Do not contact VA Medical Center staff regarding this requirement, as they are not authorized to discuss this matter related to this procurement action. All questions will be addressed by the Contracting Officer Ronald Kline at ronald.kline@va.gov. Questions or Responses will include the Source Sought number 36C24423Q0623 in the subject line. All firms responding to this Request for Information are advised that their response is not a request for proposal, therefore will not be considered for a contract award. If a solicitation is issued, information will be posted on the beta.sam web site for all qualified interested parties at a later date and interested parties must respond to the solicitation to be considered for award. This notice does not commit the government to contract for any supplies or services. The government will not pay for any information or administrative cost incurred in response to this Request for Information. Information will only be accepted in writing by e-mail to Contracting Officer at ronald.kline@va.gov DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. End of Document
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/205d97daefa14faeb7bd432f85d4d0b2/view)
 
Place of Performance
Address: VA Medical Center Butler 325 New Castle Road, Butler 16001, USA
Zip Code: 16001
Country: USA
 
Record
SN06627504-F 20230324/230322230122 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.