AWARD
41 -- 4120 MRI Chiller Replacement - CI
- Notice Date
- 3/23/2023 12:49:54 PM
- Notice Type
- Award Notice
- NAICS
- 333415
— Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
- Contracting Office
- NETWORK CONTRACT OFFICE 23 (36C263) Saint Paul MN 55101 USA
- ZIP Code
- 55101
- Solicitation Number
- 36C26323P0404
- Archive Date
- 04/07/2023
- Point of Contact
- Timothy E. Kimmel, Steve Hernandez
- E-Mail Address
-
Timothy.Kimmel@va.gov, Steven.Hernandez3@va.gov
(Timothy.Kimmel@va.gov, Steven.Hernandez3@va.gov)
- Award Number
- 36C26323P0404
- Award Date
- 03/23/2023
- Awardee
- Carrier Corporation FL 33418-7231 USA
- Award Amount
- 64750.00
- Description
- STATEMENT OF WORK ������������������������������������������������������������������������������������������������������������������ ����� SCOPE: Engineering has a need to replace the �Chiller which supplies chilled water to the air handler and air conditioner for the MRI room and MRI mechanical room in building 1. The chiller has been having many issues and it has R-22 refrigerant in it which is being phased out by the EPA. �Because of the many issues and the R22 it has a high risk of possible failure and is a possible environmental hazard. If the chiller would fail it would leave the MRI without cooling for direct patient care and the MRI equipment. The Chiller is located outside on the east side of the MRI building at the Des Moines, IA VACIHCS. �All work will be performed during after normal hours and or on the weekend and must be coordinated with the COR at a minimum of 60 days prior to the start date to allow VA staff to prepare for the electrical outage. Each transformer will be replaced on separate days. �������������� Services to be performed by the Contractor. ��������� 1. Complete a pre removal inspection/test of existing equipment. ������������������������� 2. Supply the chiller, all parts, materials, and supplies needed and transport to the work site. 3. Coordinate with the COR to shut down the MRI Chiller and Imaging staff. 4. Isolate and disconnect the chiller water lines/piping. 5. Isolate and disconnect/remove all power sources. 6. Remove the old Chiller and dispose of it at no additional cost to the Government. 7. Reconnect the chiller water lines/piping. 8. Insulate piping 9. Reconnect all power sources. Install new external electrical disconnect switch � 60 Amp- NEMA 4) 10. Ensure controls wires are installed. 11. Preform the factory startup. 12. Test for proper operation and inform COR when work has been completed. 13. Provide training for the new chiller operation. 14. Provide the COR with copies of the owner/operator manuals and warranty documentation/items. 15. Rigging and lifting devices needed to lift the chillers will be provided by the contractor. � 16. The Contractor will provide and use proper personnel barricades during use of lifting equipment. Emergency Services: Contractor shall respond immediately to the COR after identification of an emergent problem or damage that may occur during the removal or installation of the fore mentioned equipment. Under these conditions of equipment failure, the Contractor shall be required to perform necessary and immediate repairs to the area at no cost to the Government and will be expected to continue work until the repairs are made and the equipment is fully operational. Clean up: The Contractor at the end of each workday shall thoroughly clean the work area, removing all dirt, debris and waste that accumulate because of the services performed. All hazardous waste resulting from the repairs will be removed and properly disposed of in accordance with all State, Local, and Federal regulations at no additional costs to the Government. It shall be the sole responsibility of the Contractor to comply with all State, Local, and Federal regulations including but not limited to maintaining any and all current State and Federal certifications.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/29ec57debef34a95b077b9a350123c14/view)
- Place of Performance
- Address: Palm Beach Gardens, FL 33418, USA
- Zip Code: 33418
- Country: USA
- Zip Code: 33418
- Record
- SN06627707-F 20230325/230323230108 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |