SOURCES SOUGHT

Z -- 657-21-117JB Correct Deficiencies Identified During Triennial Testing - STL, Construction

Notice Date
3/24/2023 11:15:54 AM
 
Notice Type
Sources Sought
 
NAICS
238210 — Electrical Contractors and Other Wiring Installation Contractors
 
Contracting Office
255-NETWORK CONTRACT OFFICE 15 (36C255) LEAVENWORTH KS 66048 USA
 
ZIP Code
66048
 
Solicitation Number
36C25523R0090
 
Response Due
3/31/2023 12:00:00 PM
 
Archive Date
05/30/2023
 
Point of Contact
Jennifer.Sotomayor@va.gov, Jennifer Sotomayor, Phone: 913-946-1144
 
E-Mail Address
jennifer.sotomayor@va.gov
(jennifer.sotomayor@va.gov)
 
Awardee
null
 
Description
Request for information (RFI) 36C25523Q0090, Title of Project: Correct Deficiencies Identified During Triennial Testing, Project #657-21-117JB This is a SOURCES SOUGHT ANNOUNCEMENT ONLY. It is for information and planning purposes only and shall not be construed as a solicitation announcement nor a request for proposals or quotes and does not obligate the Department of Veterans Affairs (VA) to award a contract. Responses will not be considered as proposals nor will any award be made to any parties responding to the sources sought announcement. The purpose of this Sources Sought Announcement is to conduct market research to locate interested, experienced and potential qualified constructions firms capable of completing this project. Firm must identify their socio-economic status for NAICS Code 238210, Electrical Contractors and Other Wiring Installation Contractors. The appropriate North American Industry Classification System (NAICS) code for this acquisition is 238210 with the applicable business size of $19.0 million. This sources sought seeks information for SDVOSB, VOSB and 8a companies for NAICS code 238210 Electrical Contractors and Other Wiring Installation Contractors. GENERAL SCOPE OF WORK: The Construction firm must provide construction services as delineated in the Plans and Specifications. The following deficiencies below were identified during the FY2019 Triennial Electrical Testing required under VHA Directive 1028. This project will correct deficiencies remaining after testing. New equipment shall have all the required working clearances. A. Building 1 Replacement of panels per plans and specifications. B. Building 3 Replace Panel P3 in Basement Mechanical Room 001. Provide NEMA 3R, and misc per plans and specifications. C. Building 18 Replace transformer and panel(s) per plans and specifications. D. Building 24 Replace panels in Ground Floor Kitchen Room G06 per plans and specifications. E. Building 25 replace panels per plans and specifications. F. Building 51A Replace switchboard and other issues per plans and specifications. G. Building 53 - Replace (3) obsolete transfer switches and transformer per plans and specifications. H. The majority of electrical equipment in this facility has sprinkler heads, related water pipes and drainpipes directly over or within the spray pattern of the electrical equipment as represented by the picture to the right. Install protective covers to prevent water from getting into the electrical equipment nor are physical protective devices installed to protect the actual sprinkler heads from physical damage. Both are required by National Electric Code section 110.26(F)(1)(a) through (F)(1)(d). Shields need to be installed in all areas where electrical components are within the spray pattern or have overhead water lines to prevent damage to prevent overhead water sources (sprinklers and water lines) from penetrating the enclosures. Such penetration could lead to a potentially catastrophic failure. Protective covers or cages need to be installed on unprotected sprinkler heads to prevent accidental activation with the same potential for catastrophic failure as mentioned above per plans and specifications.. END OF SCOPE OF WORK. The Government is not obligated, nor will it pay for or reimburse any costs associated with responding to this sources sought synopsis request. This notice shall not be construed as a commitment by the VA to issue a solicitation or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued.  If interested in this opportunity, please provide Capability Statement via email. The Capability Statement is designed to inform the Department of Veteran Affairs, of any prospective construction contractors' project execution capabilities. The submission is limited to 10 pages which shall include the following information: 1) Offeror's name, address, point of contact, phone number, e-mail address, and DUNS number; 2) Offeror's interest in bidding on the solicitation when it is issued; 3) Offeror's capability to perform a contract of this magnitude and complexity and comparable work performed within the past 5 years - brief description of the project, customer name, timeliness of performance, customer satisfaction, and dollar value of the project) - provide at least 1 no more than 3 examples; 4) Offeror's CVE certification if a Veteran owned business; 5) Please provide Socio-economic status for NAICS code 238210, Electrical Contractors and Other Wiring Installation Contractors and provide percentage of self-performed labor your company can perform for this type of project. 6) Offeror's Joint Venture information if applicable - existing and potential; 7) Offeror's Bonding Capability in the form of a letter from Surety providing bonding level per contract and aggregate. 8) Letter from Insurance Company identifying Contractors Insurance Experience Modification Rate (EMR). Notice to Potential Offerors: All Offerors who provide goods or services to the United States Federal Government must be registered in the System for Award Management (SAM located on the web at www.sam.gov). It is desirable that any Offeror have completed their business Online Representations and Certifications Application (ORCA). Additionally, all Service-Disabled Veteran Owned Businesses or Veteran Owned Businesses who respond to a solicitation on this project must be registered with the Department of Veterans Affairs Center for Veterans Enterprise VetBiz Registry located at http://vip.vetbiz.gov.  Submittal Information: Responses shall indicate the RFI #36C25523Q0090, Title of Project: Correct Deficiencies Identified During Triennial Testing, Project #657-21-117JB. Please be advised that all submissions become Government property and will not be returned. All interested Offerors should submit information by e-mail to: Jennifer.Sotomayor@va.gov. All information submissions should be received no later than 2:00 pm CDT on Friday, March 31, 2023. END OF RFI.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/c3dda8a3ea3f4b5982707c68f64fd166/view)
 
Place of Performance
Address: Sl Louis VAMC Jefferson Barracks 1 Jefferson Barracks Drive, St. Louis 63125, USA
Zip Code: 63125
Country: USA
 
Record
SN06630128-F 20230326/230324230115 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.