SOLICITATION NOTICE
M -- The U.S. Consulate General Toronto 3rd Floor Washroom Restoration
- Notice Date
- 3/31/2023 1:45:51 PM
- Notice Type
- Presolicitation
- NAICS
- 236220
— Commercial and Institutional Building Construction
- Contracting Office
- AMERICAN CONSULATE TORONTO WASHINGTON DC 20520 USA
- ZIP Code
- 20520
- Solicitation Number
- 19CA7023Q0003
- Response Due
- 5/15/2023 1:00:00 PM
- Point of Contact
- Kelly Gerstbacher, Phone: 416-595-6531, Afrin Sarmin, Phone: 416-595-1700
- E-Mail Address
-
GerstbacherKA@state.gov, AfrinSL@state.gov
(GerstbacherKA@state.gov, AfrinSL@state.gov)
- Description
- Scope of Workfor Washrooms Restoration on 3rd Floor at the U.S. Consulate General Toronto Demolition: 1. Remove and dispose of hallway door and frame to accommodate appropriately sized ABA entranceway to the washrooms 2. Remove and dispose of vestibule door in a manner that allows for proper installation of stainless-steel caps 3. Remove and dispose of 2 toilets 4. Remove and dispose of partitions around toilets 5. Remove and dispose of urinal when applicable 6. Remove and dispose of sink 7. Remove and dispose of floor and wall tiles � 8.�Remove and retain the radiator cover for re-use in the renovated bathrooms. 3RD FLOOR HALLWAY WILL BE BOARDED OFF FROM THE BATHROOM AREAS BEING WORKED ON USING PLYWOOD for the duration of the project. ACCESS TO THE CONSTRUCTION ZONE WILL BE THROUGH A LOCKABLE DOOR BUILT INTO THE END OF THE BOARDING. WORK AREA WILL BE COMPLETELY SEALED AS TO RETAIN ALL DUST AND DEBRIS. Cleaning up of any dust and debris created from the construction activities will be responsibility of the contractor on a daily basis. Construction: � 1. Widen Hallway door opening to accommodate a 36"" door and frame of appropriate thickness for the wall. 2. Install new wooden 36"" hallway door with automatic door operator and 2 operating paddles, handicap/brail signage, frosted site glass, 5 1/4""w x 65""h and stainless-steel push plate on the outside, stainless steel plate and pull handle on the inside Install new 36"" wooden hallway door with automatic door operator and 2 operating paddles, handicap/brail signage, frosted site glass 5 1/4""w x 65""h and stainless-steel push plate on the outside, stainless steel plate and pull handle on the inside 3. The vestibule door opening to be capped off with brushed stainless-steel caps. Vestibule opening must be 36� wide. 4. Install new vestibule light 5. Cap off plumbing and remove terrazzo floor and replace with floor tile throughout the entire bathroom. Transition from hallway to bathroom shall be flush. 6. Replace wall tiles throughout the entire bathroom area from floor level up to the height of the existing tiles. 7. Install new toilet partitions with a 34"" door opening. Partitions to include privacy strips to cover over seams between the partitions and the door������������ 8. Install 1 new ABA comfort height compliant toilet and replace existing flush unit with new similar type. 9. Reinstall trap seal primer. 10. Drill floor and redo plumbing to accommodate relocation of 1 toilet. 11. Install 1 new urinal with assoc. plumbing and new flush unit similar to existing 12. Install 2 stainless steel sanitary napkin disposal boxes 13. Install grab bars behind and beside 1 toilet in accordance with ABA specifications. 14. Install new toilet paper dispenser in accordance with ABA specifications. Dispenser must be able to hold 2 rolls of all brands of 9"" paper rolls. 15. Install new vanity countertop in accordance with ABA specifications. Countertop to contain holes appropriate for the installation of the faucet agreed upon. 16. Install new sink with automatic faucet, mixing valve and proper pipe insulation under counter in accordance with ABA specifications. 17. Install new sink with automatic faucet, mixing valve and proper pipe insulation under counter in accordance with ABA specifications. 18. Install 1 new mirror in accordance with ABA specifications. Size to be 24�w x 36�h. 19. Install new paper towel dispenser. 8"" Hands Free Dispenser, 16"" x 13"" x 10"", Manual, No Batteries Required, Pull towel off, next one appears. No levers or push buttons. 20. Install new garbage can 21. Install manual soap dispenser. Dispenser needs to be able to accommodate Scott 1 liter soap cartridges. 22.�Install new T-Bar ceiling grid and tiles in washroom and vestibule areas 23. Install manual soap dispenser. Dispenser needs to be able to accommodate Scott 1 liter soap cartridges. 24.�Install 2 new LED flat panel light fixtures with ceiling mounted dual sensor motion 25. Install 1 baby change table 26.�Install 6� baseboard around the vestibule area with bathroom�s floor tile material. 27.�Repair wall wherever needed due to plumbing removal and damage that may occur 28.�Retain floor drain �29. Install hot and cold water shut off valve inside the washroom wall area� (if not existing) for hot & cold water.� � � � � � � � � � � � � � � � � � � � � � � � � 30. Install water shut off valve inside the�washroom wall area (if not existing)�for hot and cold water.�������� �31. Retain proper ventilation of the washroom������� 32. Retain proper ventilation of the washroom. Installations to also include repairs as below: Holes where plumbing will be removed and capped.����������������������������������� Damage caused by installing door operating buttons in men's and ladies needs to be remedied. Damage caused by installing grab bar anchors must be repaired. Grab bars/ baby change tables may not be able to be mounted to existing tile due to air gap between tile and the wall.� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � �� Replacement items to be of greater than, or comparable value to the following items:������������������������������� ����������������������������������������������������������������������������������������������������������������������������������������������� DOOR OPERATOR - Electromechanical operator, hardwired, complies with North American and European standards and requirements for low-energy power operated doors. Silent and smart applications with high intelligent functions. Safe, reliable and quiet operation or public service environments door opens automatically when manually pushed from the closed position, and �Power Assist�, providing motorized assistance when the door is pulled opened by hand. The smart control unit offers monitored battery backup for convenience. Features are smart lock functions for security, monitored sensors and low-energy consumption. Technical specifications: Power consumption max. 75 W Auxiliary voltage 24 V DC, max. 400 mA Monitored battery backup unit 24 V DC Electromechanical locking connection 12 V DC max 500 mA or 24 V DC max 250 mA Ambient temperature -20�C to +45�C Relative humidity (non-condensing) max 85% Max recommended Inertia J For PUSH = 45 kgm� For PULL = 16 kgm� J = Door weight x (Door width)�/3. Besam SW-100 or equivalent. PADDLES � Hardwired to match existing, surface mount with stainless enclosure, blue print on stainless steel button BEA push plates, Model # 10PBR451 or equivalent. LIGHT FIXTURE - RECESSED LIGHT, 35 Watts LED equivalent PARTIONS - 304 Stainless Steel, to include all mounting hardware, hinges, coat hooks, etc. as per drawings.� The partitions openings need to be configured as such to maintain privacy. If needed, privacv plates are to be installed at the Governments discretion at no additional cost. TOILETS - Handicapped, White, 6L/fl., elongated bowl, comfort height, toilet seat, (white with open front, no lids), with new flush unit equivalent to existing .��������������������������������������������������������� ����������������������������������������������������������������������������������������������� ����������������������� URINAL - Vitreous china, Low-consumption, (3.8 Lpf/1.0 gpf),� Flushing rim,� Siphon jet flush action,� Extended sides for privacy, 3/4"" inlet spud, Outlet connection threaded 2"" inside (NPTF),� 2 wall hanger,� Meets ANSI flush requirements at 1.0 GPF, 6561.017 Top spud, Nominal Dimensions: 356 x 445 x 679mm (14"" x 17-1/2"" x 26-3/4"") Recommended working pressure � between 20, psi at valve when flushing and 80 psi static2008/CSA B45.1-08 for Vitreous China Fixtures, Meets or Exceeds the Following Specifications: � ASME A112.19.2- Compliance Certifications.������������������������������������������ ����������������������������������������������������������������������������������������������������������������������������� SANITARY NAPKIN DISPOSAL BOX - Surface Mounted Sanitary Napkin Disposal. Stainless steel with a satin finish. Covered. The cover is secured to the cabinet with a stainless-steel piano hinge. Bobrick, Model # 44HBM or equivalent.������������������������������������������������������������������������������������������������ ����������������������������������������������������������������� GRAB BARS - 1 - 36"" long, 1 - 24"" long per ADA specifications.������������������������������������������������������� ����������������������������������������������������������������������������������������������������� TOILET PAPER DISPENSER - Able to hold 2 rolls of all brands of 9"" paper rolls. U-Line, Model # H-1347 or equivalent����������������������������������������������������������������������������������������������������������������������������������� ������������������������ ���������������������������������������� VANITY COUNTERTOP - Marble, approx. 40""w x 24""d, (not less than 40� unless agreed upon by the Government representative prior to fabrication), complete with substantial wall support to avoid damage, (coming lose or falling off the wall during use by the public). Counter to extend the complete distance from the exterior wall to the partition panel on the other side of the countertop.����������������������������������� ����������������������������������������������������������������������������������������������������������������������������� SINK - American Standard, Model # 29196, surface mounted or equivalent.���������������������������������������� ����������������������������������������������������������������������������� AUTOMATIC FLOW CONTROL FAUCET - DELTA COMMERCIAL, model # 591-LGHGMHDF or 590T1250 or equivalent��������������������������������������������������������������������������������������������������������������������� MIXING VALVE - Delta Commercial R2900-MIX, with thermostatic limit stop or equivalent���������������� ����������������������������������������������������������������������������������������������������������� �PIPE INSULATION - Lav Guard 2, pipe covering to include supply lines as well as drains or equivalent����������������������������������������������������������������������������������������������������������������������������������������������������������� MIRROR - 24""w x 36""h with stainless steel frame in accordance with ABA specifications.���������������� ����������������������������� ����������������������������������������������������������������������������������������������������������������������������������������������� Install manually operated soap dispensers that are able to accommodate Scott Brand 1 litre foamy soap cartridges. (not liquid soap dispensers). PAPER TOWEL DISPENSER - 8"" Hands Free Dispenser, 16"" x 13"" x 10"", Manual, No Batteries Required, Pull towel off, next one appears. No levers or push buttons. Kimberly Clark, Model # H-2272 or equivalent������������������������������������������������������������������������������������������������������������� ����������� HAND DRYERS - Dyson hand dryers to be supplied by the Government�������������������������������������� ����������������������������������������������������������������������������������������������������������������������������������������������� GARBAGE CAN - 14""h x 12"" w, open mesh basket type for under the counter - TBD����������������������� ����������������������������������������������������������������������������������������������������������������������������������������� CEILING TILES - Armstrong, 2' x 4', Dune, Second look II, Humiguard Plus, 2712A or equivalent�� ����������������������������������������������������������������������������������������������������������������� ����������������������������������������������������������������������������������������������������������������������������������������������� CEILING LIGHTS - 2x4 foot, LED Flat Panel fixtures, to fit in ceiling grid���������������������������������������� ����������������������������������������������������������������������������������������������������������������������������� CEILING MOUNTED SENSOR FOR LIGHTS - Hubbell ATD500C H-Moss dual occupancy ceiling sensor c/w power pack or equivalent������������������������������������������������������������������������������������������������������� ����������������������������������������������������������������������������������������������������������������� WALL TILE - TBD, 12"" x 24 "" CENTURA or equivalent, GROUT - White or similar tone��������������� ����������������������������������������������������������������������������������������������������������������������������������������� FLOOR TILE - 12""x24"" Slip resistant porcelain or equivalent, GROUT - Color should coordinate with tile BABY CHANGE TABLE - Rubbermaid, FG781888LPLAT, or equivalent.���� All accessories to be cleared off on by the COR before items are placed on order. The COR can refuse any or all of the submitted proposals for accessories as they see fit to comply with the Scope of work as above. Attachment: ABA Standards (enhanced single file version) (access-board.gov) shall be referenced in conjunction with the layout and placement of the above items needed to complete the layout, and installation of partitions and fixtures within the restrooms according to ABA Standards
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/adaa1561d6d04baf98d3cde2d16dcaff/view)
- Place of Performance
- Address: Toronto, ON, CAN
- Country: CAN
- Country: CAN
- Record
- SN06636657-F 20230402/230331230108 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |