SOURCES SOUGHT
J -- Ventilation & Cleanroom Testing
- Notice Date
- 4/3/2023 6:26:51 AM
- Notice Type
- Sources Sought
- NAICS
- 333413
— Industrial and Commercial Fan and Blower and Air Purification Equipment Manufacturing
- Contracting Office
- 247-NETWORK CONTRACT OFFICE 7 (36C247) AUGUSTA GA 30904 USA
- ZIP Code
- 30904
- Solicitation Number
- 36C24723Q0521
- Response Due
- 4/7/2023 9:00:00 AM
- Archive Date
- 05/07/2023
- Point of Contact
- Alecia Mitchell, Contract Specialist, Phone: (478) 272-1210
- E-Mail Address
-
Alecia.mitchell@va.gov
(Alecia.mitchell@va.gov)
- Awardee
- null
- Description
- Page 3 of 3 THIS IS A SMALL BUSINESS SOURCES SOUGHT NOTICE REPRESENTING A MARKET SURVEY AND IS NOT A REQUEST FOR PROPOSALS, PROPOSAL ABSTRACTS, QUOTATIONS OR INVITATION FOR BIDS The Department of Veterans Affairs is conducting a sources sought to obtain information regarding: (1) the availability and capability of qualified small business sources; (2) whether they are Service-Disabled Veteran-Owned, Veteran-Owned, Small Business, HUB Zone 8(a), Women-Owned, or small disadvantaged business concerns; and (3) their size classification relative to the North American Industry Classification System (NAICS) code for the proposed acquisition. Your responses to the information requested will assist the Government in determining the appropriate acquisition method, including whether a set-aside is possible. An organization that is not considered a small business under the applicable NAICS code should not submit a response to this notice. Small businesses concerns shall be capable of providing the necessary equipment and personnel to furnish service in the volume required for all the items under this contract. Contractor shall meet all requirements of Federal, State or City codes regarding operations of this type of service. The NAICS code is 333413 (Size Standard: 500 employees) The intent of this notice is to determine the availability of qualified commercial sources technically capable of providing the items below: The Contractor shall provide testing, service, transportation, and written reports on the equipment listed below. The rooms and corresponding equipment listed for service are as follows: Pharmacy IV Room (2/year, certification required every 6 months) Biological Safety Cabinet (BSC): next due by June 8, 2023 Nuaire NU-425-300 (2) i. BSC Certification x 2 PER USP 797/NSF/CETA CAGs ii. Viable Air Plate (2 samples) iii. Viable Surface Sample (2 samples) iv. Non-viable particle count v. DCA AVS with Video Recording b. Clean Room i. Air Change Rate, 30 AC/Hr., positive pressure ii. Viable Air Plate (1 sample) iii. Viable Surface (2 samples) iv. Non Viable (3 samples) v. HEPA filter Integrity vi. Room pressurization test 2. Oncology HD Buffer Room: next due by June 8, 2023 (2/year, certification required every 6 months) a. Isolator (PEC) NU-PR797400 i. Isolator Certification: NU-PR797-400 ii. Viable Air Plate (2 sample) iii. Viable Surface Sample (2 sample) iv. PEC AVS with Video Recording v. HEPA Integrity vi. Non-viable particle count b. HD Buffer Room (2/year, certification required every 6 months) i. Air Change Rate, 30 AC/Hr. ii. Viable Air Plate (1 sample) iii. Viable Surface Sample (2 samples) iv. Non Viable particle count v. HEPA filter Integrity vi. Room pressurization test 3. Non-HD Anteroom (2/year, certification required every 6 months) i. Air Change Rate, 30 AC/Hr. ii. Viable Air Plate (1 sample) iii. Viable Surface Sample (1 sample) iv. Non Viable particle count v. HEPA filter Integrity vi. Room pressurization test 4. HD (Negative) Anteroom (2/year, certification required every 6 months) i. Air Change Rate, 30 AC/Hr. ii. Viable Air Plate (1 sample) iii. Viable Surface Sample (1 sample) iv. Non Viable particle count v. HEPA filter Integrity vi. Room pressurization test 5. Canopy Hood Building 3BM Room 101-3W (2/year, certification required every 6 months) i. Face Velocity ii. Total Flow iii. Smoke Capture 6. Class 1 Containment Hood Building 3BM- Histology Basement Air Clean Systems AC632C (2/year, certification required every 6 months) i. Inflow Velocity ii. HEPA Integrity iii. AVS 7. Biological Safety Cabinet (BSC) Baker BCG-401 Building A Microbiology (2/year, certification required every 6 months) i. BSC Certification PER NSF:49 8. Grossing Station 3BM- Histology Basement (2/year, certification required every 6 months) i. Face Velocity ii. Airflow Pattern Test iii. Smoke Capture The vendor shall be a NEBB Certified Cleanroom Performance Testing that employs NSF Accredited Individuals, NEBB-Certified Technicians, and CETA-Registered Cleanroom Officials for Sterile Compounding Facilities. Potential offerors having the skills, experience, professional qualifications, and capabilities necessary to perform the described requirement are invited to provide a capabilities statement via e-mail. The Capability statements shall not exceed three (3) pages and must include the following: 1) Company name and Point of Contact information (address, telephone, e-mail, web-site, etc.); 2) DUNS number and CAGE code; 3) Small Business Size/Certification (to include 8(a), HUB Zone, SDVOSB, etc.); and (4) Familiarity and product knowledge. Responses are due no later than 1200 EST, Friday, April 7, 2023, and shall be electronically submitted to: alecia.mitchell@va.gov. All responses will be used to determine the appropriate acquisition strategy for a potential future acquisition. Response is strictly voluntary; no reimbursement will be made for any costs associated with providing information in response to this synopsis or any follow-up information requests.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/91dbc3d4540944bc80c2d5b617e90803/view)
- Place of Performance
- Address: Dublin VA Medical Center 1826 Veterans Blvd., Dublin, GA 31021, USA
- Zip Code: 31021
- Country: USA
- Zip Code: 31021
- Record
- SN06638602-F 20230405/230403230113 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |