SOLICITATION NOTICE
J -- Notice of Intent to Sole Source: Maintenance Service for Two (2) BD LSRFortessa Flow Cytometers and Associated Instrumentation
- Notice Date
- 4/4/2023 1:01:00 PM
- Notice Type
- Presolicitation
- NAICS
- 811210
—
- Contracting Office
- NIH NCI Bethesda MD 20892 USA
- ZIP Code
- 20892
- Solicitation Number
- 75N91023Q00063
- Response Due
- 4/12/2023 1:00:00 PM
- Point of Contact
- Lena Lee, Contract Specialist, Reyes Rodriguez, Contracting Officer
- E-Mail Address
-
lena.lee@nih.gov, reyes.rodriguez@nih.gov
(lena.lee@nih.gov, reyes.rodriguez@nih.gov)
- Description
- The National Institutes of Health (NIH), National Cancer Institute (NCI), Center for Cancer Research (CCR), Center for Immuno-Oncology (CIO) requires preventative maintenance and emergency services for two (2) BD LSRFortessa Flow Cytometers and their associated instrumentation. The Office of Acquisitions (OA) plans to procure, on a sole source basis, maintenance services for this specialized equipment from: BD Biosciences (2350 Qume Drive, San Jose, CA 951311) The response close date of this notice for this requirement is in accordance with FAR 5.203(a)(1). This acquisition will be processed under FAR Part 12 and will be made pursuant to the authority in FAR 13.106-1(b)(2) and, in accordance with FAR 13.501, is exempt from the requirements of FAR Part 6.� The North American Industry Classification System (NAICS) code is 811210 � Electronic and Precision Equipment Repair and Maintenance; and the small business size standard is $34 million. This acquisition is to acquire maintenance services for the following Government-owned equipment: one (1) BD Biosciences LSRFortessa Special Order Research Product (SORP) Flow Cytometer Model Number:� 647177������� Serial Number: H64717700171 inclusive of computer workstation and the following components: Lasers SAPPHIRE 488-100 LP Blue (Serial #11173) OBIS 640-100 LX Red (Serial #11174) SAPPHIRE 561-50 Y/G (Serial #11175) Cube 405-100 SORP Laser (Serial #11176) GENESIS 355-60 UV (Serial #11177) one (1) BD FACS Flow Supply System Model Number:� 337755������� Serial Number: N3492774982 one (1) BD High Throughput Sampler Model Number:� 337756������� Serial Number: U33865907054 one (1) BD Biosciences LSRFortessa Special Order Research Product (SORP) Flow Cytometer Model Number:� 647177������� Serial Number: R64717700214 inclusive of computer workstation and the following components: Lasers OBIS 488-100 LS Blue (Serial# 14112) OBIS 640-100 LX Red (Serial# 14113) OBIS 405-100 LX Violet (Serial# 14114) OBIS 561-100 LS Y/G (Serial# 14115) GENESIS 355-60 w/BD UV (Serial# 14116) one (1) BD FACS Flow Supply System Model Number:� 337755������� Serial Number: N3492775835 To NCI�s knowledge, BD Biosciences is the only maintenance service provider for their flow cytometers, such as the LSRFortessa SORP Flow Cytometer. This instrument is used extensively by CIO research staff to isolate cell subpopulations from patients to better understand their role in fighting specific types of cancers.� It cannot be out of service for any length of time.� BD Biosciences is the only known vendor that can provide the required specialized maintenance services, including access to the proprietary parts that BD uses on its instruments, or the ability to provide on-site repairs within 72 hours of notification.� The hardware and software is proprietary to BD, which makes it the only company capable of providing the specialized maintenance services. This notice is not a request for competitive quotation. However, if any interested party, especially small businesses, believes it can meet the above requirement, it may submit a capability statement, proposal, or quotation, which shall be considered by the agency. �The statement of capabilities and any other information furnished must be in writing and must contain material in sufficient detail to allow the NCI to determine if the party can perform the requirement. �Responses must be received no later than 4:00PM EST, April 12, 2023.� All responses and questions must be in writing and emailed to Lena Lee, Contract Specialist, via electronic mail at lena.lee@nih.gov. �A determination by the Government not to compete this proposed requirement based upon responses to this notice is solely within the discretion of the Government. Information received will be considered solely for the purpose of determining whether to conduct a competitive procurement. No collect calls will be accepted. In order to receive an award, Contractors must be registered and have valid, current Entity Record, including current Representations and Certifications, in the System for Award Management (SAM) through SAM.gov. Reference: 75N91023Q00063 on all correspondence. ***Please reference the attached Statement of Work for more details pertaining to the nature of the work to be performed.*** This notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use the information provided by respondents for any purpose deemed necessary and legally appropriate. Confidentiality. No proprietary, classified, confidential, or sensitive information should be included in your response. The Government reserves the right to use any non-proprietary technical information in any resultant solicitation(s).
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/2ef8cbdc118d4c18b18d26bcf40d7754/view)
- Place of Performance
- Address: Bethesda, MD 20892, USA
- Zip Code: 20892
- Country: USA
- Zip Code: 20892
- Record
- SN06639153-F 20230406/230404230105 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |