SOURCES SOUGHT
Y -- Barkley Dam Water and Compressed Air Lines Replacement
- Notice Date
- 4/6/2023 1:30:56 PM
- Notice Type
- Sources Sought
- NAICS
- 237110
— Water and Sewer Line and Related Structures Construction
- Contracting Office
- US ARMY ENGINEER DISTRICT NASHVILLE NASHVILLE TN 37203-1070 USA
- ZIP Code
- 37203-1070
- Solicitation Number
- W912P523SSAR0003
- Response Due
- 4/20/2023 11:00:00 AM
- Point of Contact
- Andrew Roth, Phone: 6157367793
- E-Mail Address
-
andrew.r.roth@usace.army.mil
(andrew.r.roth@usace.army.mil)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Description
- Sources Sought Notice for Barkley Dam� Water Lines� BARKLEY DAM WATER AND COMPRESSED AIR LINES REPLACEMENT THIS IS NOT A SOLICITATION, INVITATION FOR BID (IFB), REQUEST OFR QUOTE (RFQ), OR A REQUEST FOR PROPOSAL (RFP).� This is a sources sought announcement only. This sources sought is for acquisition planning purposes only and shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract. Any cost incurred as a result of the announcement shall be borne by the interested party (prospective offeror) and will not be charged to the government for reimbursement. Respondents will not be notified of the results of any government assessments.� PURPOSE:� The U.S. Army Corps of Engineers Nashville District is conducting this Sources Sought in support of Market Research to notify and seek potential qualified members of industry to gain knowledge of capabilities, interest, and qualificaitons; to include the Small Business Community for completing the work effort relative to the installation of new potable water liens, compressed air lines, replacement of vertical pipe hangers, demolition of abandoned compressed air line, water lines, and assorted valves. Responses to this Sources Sought Synopsis will be used by the Government in making appropraite acquisition decisions. The Government must ensure there is adequate competition in making appropriate decisions. The type of set-aside acquisition will depend upon the responses to this sources sought announcement.� NO SOLICITATION EXISTS AT THIS TIME.� SCOPE OF WORK (SUBJECT OT CHANGE):� The work consists of the effort related to installation of approximately 1,200 feet of 3"" HDPE DR 9 potable water pipe and approximately 1,200 feet of galvanized steel compressed air pipe in the dam grouting gallery. The contractor will also be responsible for replacing the vertical seciton of 3"" potable water pipe and 2"" compressed air pipe in the powerhouse hoistway. The Contractor will also be responsible for the replacement of 9 vertical hangers for the 3"" potable water line, the demolition of abandoned 2"" compressed air line and water lines, and assorted valves.� Location: Barkley Dam SIte, Grand Rivers, KY� Period of Performance: Unknown Disclosure of the Magnitude of the Proposed Construction Project: Between $250,000 and $500,000.� ANTICIPATED NAICS CODE AND SIZE STANDARD: 237110- Water and Sewer Line and Related Structures Construction; $45.0M CAPABILITY STATEMENT TO SHOW INTEREST AND INTENT:� Respondents interested in performing the proposed project as a prime contractor should submit a capability statement for consideration that incldue the follwoing (in A through I):� A. Offeror's name, address, points of contact with telephone numbers and email addresses.� B. UEI and CAGE Code� C.� Are you a small business under this NAICS Code? D.� Business size/ classification to include any designations (Small Business, HUBZone, 8(a), Women Owned, Service-Disabled Veteran Owned, etc.) E.� A Statement of Capability (SOC) stating your skills, experience, and knowledge to perform the specified type of work as described above. This SOC should be brief description of your company�s capability. Include a statement detailing any special qualifications and certifications, applicable to the scope of this project, held by your firm and/or in-house personnel. Please provide up to three (3) projects of similar scope or size performed within the last ten (10) years. F.��Indicate whether your company will perform the work directly or intends to subcontract the work. If subcontracting, identify the percentage of work to be subcontracted. Identify the percentage of work your firm may be capable of directly performing. G.��A statement regarding past bonding and evidence of your bonding capability. H.��Please indicate whether your firm will submit an offer for this project. I.��Any other information that would assist in determining your company�s capability in performing the described construction work.� SUBMISSION OF CAPACILITY STATEMENT:� Submit this informaiton to Andrew Roth, Contract Specilaist, U.S. Army Corps of Engineers via email to Andrew.R.Roth@usace.army.mil.�Your response to this Sources Sought notice must be received by 1:00PM Central Time on Thursday 20 April 2023. DO NOT SUBMIT PROPIETARY INFORMATION AND/OR BUSINESS CONFIDENTIAL DATA. EMAIL IS THE PREFERRED METHOD WHEN RECEIVING RESPOSNES TO THIS SYSNOPSIS. As a reminder, this Sources Sought announcement notice should not be construed in any manner to be an obligation to issue a contract or result in any claim for reimbursement of costs for any effort you expend in responding to this request. No solicitation is currently available. Any future solicitation package will be made available on the SAM website https://sam.gov. Interested parties are solely responsible for monitoring SAM.gov for the release of a solicitation package and/or any updates/amendments. Search keyword �W912P5� to obtain a complete listing of all Nashville District U.S. Army Corps of Engineers opportunities.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/365ffb5cd2b84f6ca0a2e0b53d330992/view)
- Place of Performance
- Address: Grand Rivers, KY 42045, USA
- Zip Code: 42045
- Country: USA
- Zip Code: 42045
- Record
- SN06643900-F 20230408/230406230124 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)