SOLICITATION NOTICE
65 -- ORTHOPEDIC TABLE
- Notice Date
- 4/14/2023 11:15:19 AM
- Notice Type
- Presolicitation
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- 262-NETWORK CONTRACT OFFICE 22 (36C262) Gilbert AZ 85297 USA
- ZIP Code
- 85297
- Solicitation Number
- 36C26223Q0874
- Response Due
- 4/20/2023 4:00:00 PM
- Archive Date
- 06/19/2023
- Point of Contact
- John Harrison, Contract Specialist, Phone: 562-766-2267
- E-Mail Address
-
john.harrison2@va.gov
(john.harrison2@va.gov)
- Awardee
- null
- Description
- REQUEST FOR INFORMATION: 36C262-23-Q-0874 THIS IS NOT A SOLICITATION. THIS REQUEST FOR INFORMATION (RFI) IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION. THE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION ARE HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 15.201(e). THIS IS NOT A SOLICITATION ANNOUNCEMENT. This is a sources sought synopsis for market research purposes ONLY. The purpose of this synopsis is to gain knowledge of potential qualified Service-Disabled Veteran-Owned Small Businesses (SDVOSB) or Veteran Owned Small Businesses (VOSB) for relative to NAICS 339112 sources (size standard of 1000 employees). Responses to this synopsis will be used by the Government to make appropriate acquisition decisions. After review of the responses to this source sought synopsis, a solicitation announcement may be published in the FedBizOpps or GSA eBuy websites. Responses to this sources sought synopsis are not considered adequate responses to the solicitation announcement. All interested offerors will have to respond to the solicitation announcement in addition to responding to this sources sought announcement. The Department of Veterans Affairs, Network 22 Contracts Office, is seeking sources to provide: Orthopedic Table for the VA Los Angeles Healthcare System. If you are interested and can provide the required supplies, please provide the requested information as indicated below. All RFI s must provide the following: (1) Company Name: Address: Phone Number: (2) Point of Contact: Email: Phone Number: (3) Company Unique Entity ID (Found at SAM.GOV): (4) Company Business Size (Large, SDVOSB, Small etc.): (5) Are you the manufacturer or distributor of the items being referenced above (or equivalent product/solution)? (6) What is the manufacturing country of origin of these items? (7) If you re a small business and you are an authorized distributor/reseller for the items identified above (or equivalent product/solution), do you alter; assemble; modify; the items requested in anyway, if you do, state how and what is altered; assembled; modified? (8) Does your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract type and number. (9) If you are an FSS GSA/NAC or NASA SEWP contract holder or another federal contract holder, are the referenced items/solutions available on your schedule/contract? (10) Please submit your capabilities regarding the salient characteristics being provided and any information pertaining to brand name or equal to items to establish capabilities for planning purposes (11) Please provide general pricing for your products/solutions for market research purposes (12) Estimated Delivery Date. Responses to this notice shall be submitted via email to: John.harrison2@va.gov Telephone responses will not be accepted. Responses must be received no later than 04/20/2023 at 4:00 PM PST. If a solicitation is issued, it shall be announced later, and all interested parties must respond to that solicitation announcement separately from the responses to this request for information. If a response to the solicitation is not received by the government representative listed above, the vendor will not be considered for award. Responses to this notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation. Please provide unofficial pricing. Notice: No remanufactures or gray market items/ supplies will not be acceptable. Interested parties of RFI must be an authorized reseller, distributor, or dealer of the O.E.M. (Original Equipment Manufacturer). Verification can be provided by an authorization letter or other documents from the OEM. Equipment shall be in accordance with the OEM terms and conditions. Brand Name part numbers are shown for Brand Name or Equal comparison. Brand Name: HANA MZU 6875 1 6530-439571 TABLE, ORTHOPEDIC TABLE HANA, 110V 1 EA MZU 6855DP-5 2 PKIT HANA DISTRACTION PAD W/STRAP 5/CS 1 EA MZU 6855 3 PKIT, HANA AND ProFx 6/CS 1 EA MZU 5857 4 Cross Arm Support w/Pad 1 EA MZU 6875-5005 5 HANA FEMUR LIFT FOOT PEDAL 1 EA MZU 6850-487 6 Hana/ProFx Traction Boot XLarge (pr) 1 EA MZU 6875-500 7 Hana Equipment Cart 1 EA MZU 5855-61 8 Accessory Clamp 1 EA MZU 6850-170 9 Hana/ProFx Lower Leg Support 1 EA MZU 6875-2761 10 FRACTURE KIT, HANA 1 EA MZU 5929DZ 11 DOZEN, 6"" PERINEAL POST COVER 1 EA MZU 6850-110 12 Hana/ProFx Femoral Hook Support Assembly 1 EA MZU 6850-140 13 Hana/ProFx Classic Femoral Hook Left Classic 1 EA MZU 6850-144 14 Hana/ProFx Classic Femoral Hook Right Classic 1 EA MZU 6850-918 15 Hana/ProFx Femoral Hook Right 1 EA MZU 6850-919 16 Hana/ProFx Femoral Hook Left 1 EA MZU FSC-HANA 17 FULL-SERVICE CONTRACT - 6875 1 EA TOTAL COST: $ Purpose The purpose of an Orthopedic fracture surgery table enables surgeons to perform a variety of fracture and orthopedic procedures that require specific patient positioning. Specifically in locking in hyperextension, abduction, adduction, and external rotation of the legs for femoral component placement. The unit must be specifically designed as an orthopedic fracture table. The unit must allow hyperextension, abduction, adduction, and external rotation of the legs for femoral component placement. The unit must be radiolucent (carbon fiber construction) for the table, leg spars, and top. The unit must have a hospital-grade memory foam medical pad. Must have narrow supine and lateral pelvic support options. The unit requires multiple arm board options. The unit must have femoral hooks with an independent foot control powered lift support system for use in anterior approach hip replacement surgery. The unit requires independent locking traction boots. The unit must have independently controlled lift-assisted leg spars. Leg Spar Articulation must range between 28º up and 35º down with 20º adduction and 45º abduction. A minimum lateral tilt of 12º, Trendelenburg of 12º, reverse Trendelenburg of 12º, and a minimum patient weight capacity of 450 lbs.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/44f3d67e3f93470d9835deab86f30871/view)
- Place of Performance
- Address: VA Los Angeles Healthcare System VENDOR DELIVER TO VHAGLA WAREHOUSE BLDG 297
- Record
- SN06651590-F 20230416/230414230112 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |