SOURCES SOUGHT
65 -- 521-23-3-237-0195 MANOSCAN ESO Z CATH X1 (VA-23-00064875)
- Notice Date
- 4/18/2023 6:19:15 AM
- Notice Type
- Sources Sought
- NAICS
- 339113
— Surgical Appliance and Supplies Manufacturing
- Contracting Office
- 247-NETWORK CONTRACT OFFICE 7 (36C247) AUGUSTA GA 30904 USA
- ZIP Code
- 30904
- Solicitation Number
- 36C24723Q0579
- Response Due
- 4/21/2023 1:00:00 PM
- Archive Date
- 06/20/2023
- Point of Contact
- Joseph M Locke, Procurement Analyst, Phone: 803-776-4000 x7814
- E-Mail Address
-
Joseph.locke@va.gov
(Joseph.locke@va.gov)
- Awardee
- null
- Description
- This is a sources sought announcement only. All responses will be used for market analysis in determining the availability of potential qualified businesses that may be used to determine appropriate acquisition strategy. No solicitation is being issued at this time but may be issued later. The Columbia Healthcare VA System (WJB Dorn VA Medical Center) located at 6439 Garners Ferry Road, Columbia, SC 29209 is seeking Service Disabled Veteran Owned Small Businesses (SDVOSB), Veteran Owned Small Businesses (VOSB) and vendors falling into other socioeconomic Small Business (SB) categories to provide Medtronic ESOZ Manometry or its brand name equivalent. Interested offerors are encouraged to respond to this notice via e-mail and provide their companies name and associated DUNS number. This notice will be posted for a period of 3+ business days, closing on Friday, April 21, 2023 at 4pm EST. Questions regarding this notice should be forwarded to Joseph Locke via e-mail at joseph.locke@va.gov STATEMENT OF WORK (SOW) GENERAL INFORMATION The GI/Hepatology Department needs Medtronic ESOZ Manometry. The module has not been updated since 2012. The system is at its end-of-life cycle. 1. Title of Project: Medtronic ESOZ Manometry 2. Background: The GI Department currently have a manometry system to detect different GI issues in patients during procedures. We have been having multiple issues with them that have been requiring repair on a frequent basis. 4. Period of Performance: Delivery to be made within 45 days of receipt of order. 5. Type of Contract: Fixed Price Item Product Code Product Name Qty 1 MSE-6013 A120 UPGRADE X1 1 2 3282- 3282 CALIBRATION SET UP MODULAR CARTX1 1 3 3283 MODULAR CART ACCESSORY KIT X1 1 4 FGS-4374 MANOSCAN A120 ACQUISITION MOD 1 5 WIR-0106-01 A120 Power Cord-SJT Jacket 1 6 WIR-0106-01 A120 Power Cord-SJT Jacket 1 7 4189 MANOSCAN Z A200 X1 1 8 80245 MANOMETRY 3 YEAR SVC PLAN ADD'L MOD 1 9 80240- MANOMETRY 3 YEAR SVC PLAN MOD 1 1 10 MANOSCAN ESO Z CATH X1 11 HRM CATHETER EXTENDED WARRANTY 1 YEAR SALIENT CHARACTERSITICS The Birmingham VA desires the following salient Characteristics for the Manometry Probe Probe that looks at pressure within the esophagus. Probe that can detect the pressures that accompany swallowing. Probe/Procedure that can help to diagnose achalasia and other swallowing disorders that can be used for patient who get reflux surgeries (Nissen Fundoplicaiton) System that detects narrowing of the esophagus, assesses the ability of the muscles of the esophagus to contract and pass food in the right direction (preventing aspiration of contents into the lungs) System that can determine the elasticity of the esophagus Probe used to measure the function of the lower esophageal sphincter (the valve that prevents reflux, or backward flow, of gastric acid into the esophagus) and the muscles of the esophagus. Probe/test that will assist MD with determining if your esophagus is able to move food to your stomach normally. Catheter specifications: High resolution esophageal catheter with impedance: 36 channels with 12 measuring points per sensor provide 432 points of measurement 18 impedance channels display bolus transition from pharynx to esophagus 4.2 mm diameter True circumferential sensors Part number MSC-1286 ManoScan ESO module ManoScan ESO module and catheter provide circumferential assessment of bolus movement as well as physiological mapping of esophageal motor function. Maps from the pharynx to the stomach, with a single placement of the catheter Catheter specifications High resolution esophageal catheter: 36 channels with 12 measuring points per sensor provide 432 points of measurement 4.2 mm diameter True circumferential sensors Part number MSC-1286 High resolution esophageal small diameter catheter: 36 channels with 16 measuring points pers sensor provide 576 points of measurement 2.75 mm diameter Part number MSC-3886
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/f3586523d24f4a52b4a9e77a5694ec8d/view)
- Record
- SN06654945-F 20230420/230418230127 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |