SOURCES SOUGHT
66 -- 3D Scanning and CMM System
- Notice Date
- 5/18/2023 9:52:52 AM
- Notice Type
- Sources Sought
- NAICS
- 334519
— Other Measuring and Controlling Device Manufacturing
- Contracting Office
- W2R2 CONST ENGRG LAB CHAMPAIGN IL 61822-1072 USA
- ZIP Code
- 61822-1072
- Solicitation Number
- W9132T23N5627
- Response Due
- 5/25/2023 10:00:00 AM
- Point of Contact
- Kasey Davis, Christine L. Wilson
- E-Mail Address
-
Kasey.T.Davis@usace.army.mil, Christine.L.Wilson@usace.army.mil
(Kasey.T.Davis@usace.army.mil, Christine.L.Wilson@usace.army.mil)
- Description
- The ERDC Construction Engineering and Research Laboratory (CERL) is seeking potential sources for a 3D Scanning and CMM System. Potential suppliers of this equipment are invited to provide capabilities and potential solution via email to both Kasey.T.Davis@usace.army.mil and CHL-CT-Quotes@usace.army.mil not later than 12pm (CST) 25 May 2023. Please add Email Subject ""Sources Sought Response - 3D Scanning and CMM System"" to your response.� Quotations are not sought at this time.� When providing a response, please provide CAGE Code, UEI, and Socioeconomic Indicators (if applicable).� Requirements for ALL EQUIPMENT listed below All software (developed by the manufacturer) required to operate the equipment All ancillary electrical components required to operate the equipment Software must be in house developed with a lifetime license and lifetime upgrades included in cost Onsite training for three (3) personnel for one (1) day for each unit Warranty: Lifetime support and repair of equipment; if repairs require downtime exceeding fourteen (14) days, provide temporary replacement during repair period Lifetime updates to software 3D Scanning Requirements For In Lab Analysis Must Execute/Include: Not handheld Achieve 3D scanning via non contact Markers, stickers, tags, etc are not required for 3D imaging 10 micron accuracy or better 2 micron precision or better Includes ISO and NIST certificates with traceability records Automated, 500 mm rotating stage, 360 degrees with 1 (or less) degree increment movement and at least 110 lb stage load capacity A minimum temperature range and relative humidity function of 59-86 oF, 20-80RH Does not require ambient light Supplied with calibration supplies to execute calibrations in house Auto recognizes the size of the object and adjusts scale.� Stage automatically moves to capture full object Can scan multiple objects on the stage.� Resulting data can be separated and saved individually QUATTRO lenses Integrated camera and stage Die cast body Captures color information via red blue and greed LEDs 4 or more megapixel CMOS camera High and low magnification, built-in lenses Calibration certification, inspection report and traceability diagram included Includes internal and working standard Visualizes changes in thickness and color Can change data to x,y,z coordinate system 3D Measurements from any orientation Software, in addition to the above, includes Automated data clean up Ability to combine unlimited, multiple scans Feature recognition GD&T measurements CAD Comparison capabilities CAD alignment for Best Fit, 3 feature alignment with best fit, and datum alignment Export to .STL and point could data Can create virtual cross sections at specified values Indoor Coordinate Measuring Requirements: Must Execute/Include the following Measurements are executed using a hand help probe that communicates to a base. Item being measured does not have to be on a specialized platform Design allows portability Does not require encoders, glass scales, or mechanically driven moving parts Detection via near-IR light emitted from LED panels Guides user via augmented reality Max measurement dimensions for camera base 2000 x 1200 x 1000 mm Operating temperatures at least 50-95oF Operating humidity at least 20-80% Repeatability 3 microns or better 870 nm Light Source Temperature compensation on measurements Wireless, handheld Probe OLED display At least 90 X 30 pixels Touch screen Camera Minimum display unit 0.001 mm Bluetooth, USB and infrared communication at 945 nm Theta rotation +/- 90 degrees Tilt rotation +/- 30 degrees No more than 8 lbs Stage : Detachable Accessories to accommodate full range of samples (magnetic plates, fixture plates) Uses rechargeable batteries and includes at least 4 sets batteries Battery charger Accessory equipment that supports field measurements (tripods, extension poles, setting attachments, Accessory options for the stylus: 2.5mm , 5mm, magnetic stylus, stylus calibration, Probe attachments for robotic integration Calibration cones Probe accessories for stamping Max Horizontal Measurement range: at least 3.5 ft Max Vertical Measurement Range: At least 3 ft Measurement head can fit on multiple supports: benchtop, tripod, in a machine Indoor/Outdoor Wide Area CMM Measurement Equipment Can be used in sunlight / outdoors Operational by a single users (does not require multiple people to obtain measurements) Maximum horizontal measurement range: at least 49 ft Wireless probe, free from tethering from wires, bridges, arms or other parts Mobile case Automatically collects data Can generate reports On screen visual guidance Does not require encoders, glass scales, or mechanically driven moving parts Detection via near-IR light emitted from LED panels Self Calibrated Uses three points of tracking on the probe 3 camera tracking to find the probe, track the probe and a reference camera Meets traceability standards and includes certification certificate Camera Accuracy of 28 microns or better Precision of 10 microns or better Minimum distance of measurement at least 0.001 mm Camera rotation of 90 degrees Theta, 30 degree tilt Communication Bluetooth 5.0 USB 3.0 IR 945 nm Operational temperature range at least 50-95oF Operation Humidity 20-80% RH Camera weight, no more than 29 lbs Probe Light source 870 nm light M5 Stylus Augmented Reality Measurement Guidance Display At least 2.5 inch TFT color LCD At least 240 X 320 pixels Can perform operations and measurements when away from the base Can add hand written notes Communication Bluetooth 5.0 USB 2.0 IR 945 nm Operational temperature range at least 50-95oF Operation Humidity at least 20-80% RH Max weight of base probe 2 lbs Includes all available probe size accessories Includes all calibration accessories Includes all base accessories to include fixture kits Includes accessories for portability / transportation At least 4 sets of rechargeable batteries Battery charger Tripod with accessories for mounting Positioning magnets Software Supports 2D and 3D CAD exporting Can compare CAD files Performs statistical analysis Produces inspection reports Off line sharing of software included Delivery Delivery to ERDC CERL, 2902 Newmark Drive, Champaign, IL 61822 Delivery shall include all costs associated.� Equipment shall be delivered no later than 30 September 2023
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/4f18385b57f1462a83a7e1d9047c1687/view)
- Place of Performance
- Address: Champaign, IL 61822, USA
- Zip Code: 61822
- Country: USA
- Zip Code: 61822
- Record
- SN06688070-F 20230520/230519212002 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |