SOLICITATION NOTICE
65 -- Treadmill
- Notice Date
- 5/30/2023 1:10:23 PM
- Notice Type
- Presolicitation
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- 262-NETWORK CONTRACT OFFICE 22 (36C262) Gilbert AZ 85297 USA
- ZIP Code
- 85297
- Solicitation Number
- 36C26223Q1167
- Response Due
- 6/2/2023 11:00:00 AM
- Archive Date
- 08/01/2023
- Point of Contact
- John Harrison, Contract Specialist, Phone: 562-766-2267
- E-Mail Address
-
john.harrison2@va.gov
(john.harrison2@va.gov)
- Awardee
- null
- Description
- REQUEST FOR INFORMATION: 36C262-23-Q-1167. THIS IS NOT A SOLICITATION. THIS REQUEST FOR INFORMATION (RFI) IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION. THE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 15.201(e). THIS IS NOT A SOLICITATION ANNOUNCMENT. This is a sources sought synopsis for market research purposes ONLY. The purpose of this synopsis is to gain knowledge of potential qualified Service-Disabled Veteran Owned Small Businesses (SDVOSB) or Veteran Owned Small Businesses (VOSB) for relative to NAICS 339112 sources (size standard of 1000 employees). Responses to this synopsis will be used by the Government to make appropriate acquisition decisions. After review of the responses to this source sought synopsis, a solicitation announcement may be published in the FedBizOpps or GSA eBuy websites. Responses to this sources sought synopsis are not considered adequate responses to the solicitation announcement. All interested offerors will have to respond to the solicitation announcement in addition to responding to this source sought announcement. The Department of Veterans Affairs, Network 22 Contracts Office, is seeking sources to provide: Brand Name or Equal AV Equipment for the VA Tucson Healthcare System. Brand name items are listed solely for a comparison for the brand name or equal Purchase Request. Brand name: Multiple Distributors. If you are interested and can provide the required supplies, please provide the requested information as indicated below. All RFI s must provide the following information: (1) Company Name: Address: Phone Number: (2) Point of Contact: Email: Phone Number: (3) Company Unique Entity ID (Found at SAM.GOV): (4) Company Business Size (Large, SDVOSB, Small etc.): (5) Are you the manufacturer or distributor of the items being referenced above (or equivalent product/solution)? (6) What is the manufacturing country of origin of these items? (7) If you re a small business and you are an authorized distributor/reseller for the items identified above (or equivalent product/solution), do you alter; assemble; modify; the items requested in anyway, if you do, state how and what is altered; assembled; modified? (8) Does your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract type and number. (9) If you are an FSS GSA/NAC or NASA SEWP contract holder or another federal contract holder, are the referenced items/solutions available on your schedule/contract? (10) Please submit your capabilities regarding the salient characteristics being provided and any information pertaining to brand name or equal to items to establish capabilities for planning purposes (11) Please provide general pricing for your products/solutions for market research purposes (12) Estimated Delivery Date. Responses to this notice shall be submitted via email to: John.harrison2@va.gov Telephone responses will not be accepted. Responses must be received no later than 06/07/2023 at 11:00 AM PST. If a solicitation is issued, it shall be announced later, and all interested parties must respond to that solicitation announcement separately from the responses to this request for information. If a response to the solicitation is not received by the government representative listed above, the vendor will not be considered for award. Responses to this notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation. Please provide unofficial pricing. Notice: No remanufactures or gray market items/ supplies will not be acceptable. Interested parties of RFI must be an authorized reseller, distributor, or dealer of the O.E.M. (Original Equipment Manufacturer). Verification can be provided by an authorization letter or other documents from the OEM. Equipment shall be in accordance with the OEM terms and conditions. 2062898-001 1 CASE V6.7 1 EA 0.0000 2062898-826 2 CASE WINDOWS 8.1 PREMIUM PKG w/ display 1 EA 20744.1000 2062898-490 3 CASE LANGUAGE V6.73 SP2 ENG US 1 EA 0.0000 2026714-078 4 PHTM CASE NORTH AMERICAN POWER CORD 1 EA 0.0000 2062898-740 5 PHTM Casev6.7 CAM 14 Stress AHA 1 EA 0.0000 2062898-050 6 PHTM CASE V6.7 12SL 1 EA 668.2500 2079072-001 7 TANGO M2 GENERIC ATO MODEL 1 EA 0.0000 2079072-020 8 TANGO M2 BASE UNIT - ROHS 1 EA 5265.0000 2079072-006 9 PHTM TANGO M2 PWRCRD US-CANADA 1 EA 0.0000 2079072-021 10 PHTM TANGO M2 LANG ENG - ROHS 1 EA 0.0000 2071179-006 11 SPLY TANGO M2 CUFF ORBIT-K SMALL ADULT 1 EA 222.7500 2071179-013 12 SPLY TANGO M2 LPXPOD KIT 1 EA 850.5000 2073320-065 13 ECG SPLITTER CABLE - ROHS 1 EA 101.2500 2040577-001 14 SET ADDITIONAL DEVICE MOUNTING for CASE 1 EA 243.0000 1092405-001 15 T2100-ST TREADMILL 1 EA 0.0000 1092405-022 16 T2100-ST2 TREADMILL 220V 1 EA 5572.8000 1092405-041 17 CABLE RS232 INTERFACE T2100ST to CASE/PC 1 EA 52.6500 2104768-001 18 GE Thermal Paper 8.5""x11"", Red Grid 1 EA 88.0000 200mm Wide, 88.000 88.00 Z-Fold, Hole Queue, 300 Sheets/8 Packs 2104779-001 19 ECG Snap Electrode Foam Tear Drop 1 EA 154.7100 Wet Gel, 38.1mm/1.5"", 600 Electrodes/Case INSTALL CASE 20 INSTALLATION CASE 1 EA 0.0000 INSTALL CASE 21 INSTALLATION CASE 1 EA 0.0000 HANDL LING 22 SPECIAL HANDLING SERVICE 1 EA 250.0000 2091267-001 23 DCAR ONE DAY ON-SITE CLINICAL PRODUCT 1 EA 2500.0000 TRAINING for CARTS & STRESS, 1.00 EA INSTALL CARD INSTALLATION CARDIOLOGY SERVICE INSTALL CARD 24 INSTALLATION CARDIOLOGY SERVICE 1 EA 0.0000 ET WARRANTY 25 CASE STRESS SYSTEM Extended Warranty 1 EA 4395.0000 TOTAL COST: $ Salient Characteristics: Treadmill Safety Dual comparative speed sensors Auto runaway shutdown Auto communication loss shutdown Manual twist lock Emergency Stop button Manual Stop Tether Braking system for safe patient off-loading Fire-rated motor pan hood enclosure Weight Patient weight capacity 500 lb., 227 kg Treadmill net weight: 425 lb., 193 kg Drive System Heavy-duty 6-peak hp. brushless, DC servo motor Power Requirements 110-120VAC, 1-phase, 60 Hz, 20-amp power supply Must have dedicated 20A service Speed Range 0.1 to 15.0 mph, 0.2 to 24.0 km/h, self-calibrating and adjustable in 0.1 mph 0.1 km/h increments. Incline Range 0 to 25%, 0.5% incremental movements, self-calibrating. Running Surface 22 in. x 63 in., 56 cm x 160 cm Master Track® running belt tracking system Cushioned running deck absorbs shock of foot falls Self-lubricated and reversible running deck Step-up, low profile deck height (7 in., 18 cm from floor) Communication Ports RS232 Female Serial port USB 1.0 B port Floor Surface Footprint 33.0 in. x 78.5 in., 84 cm x 200 cm level surface. Operating and Storage Condition Recommendations Operating Temperature Range: 4.5° to +38° C (+40° to +85° F) Storage Temperature Range: -40° to +70° C (-40° to +158° F) Operating and Storage Relative Humidity Range: 10% - 90%, non-condensing Altitude: -50 to 5,280 feet Optional Features Adjustable height handrail:31.2 in (79 cm) to 37.5 in (92.5 cm) as measured from the top of the running surface
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/c29aff5120404dacbf4c02bf315de0fb/view)
- Place of Performance
- Address: VA Tucson Healthcare System
- Record
- SN06698351-F 20230601/230530230122 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |