SOLICITATION NOTICE
44 -- A23-050 Portable Air Filtration Unit Solicitation
- Notice Date
- 6/1/2023 12:39:46 PM
- Notice Type
- Solicitation
- NAICS
- 333415
— Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
- Contracting Office
- FA8125 AFSC PZIMA TINKER AFB OK 73145-3303 USA
- ZIP Code
- 73145-3303
- Solicitation Number
- FA812523Q0072
- Response Due
- 6/9/2023 1:00:00 PM
- Archive Date
- 06/24/2023
- Point of Contact
- Sondra Callaway, Darla DeAngelis
- E-Mail Address
-
Sondra.Callaway@us.af.mil, darla.deangelis@us.af.mil
(Sondra.Callaway@us.af.mil, darla.deangelis@us.af.mil)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Description
- The purpose of this amendment is to add the diagram, approved filters list, and extend the solicitation to June 9, 2023. � � � � � � � �Portable HEPA Air Filtration Unit � � � Item Description The 76th AMXG is requesting the purchase of �Portable HEPA Air Filtration Unit. This unit will be used for collection of dust / debris from blasting operations. �(i.e. paint / coating removal) � � This requirement must have the following specifications: 1.�� �One (1) Portable Air Filtration unit, with the following specifications: a.�� �Shall have an air filtration system comprised of the following types of filter in sequential order (refer to attached sketch):� i.�� �Automatically purging dust collection filter system ii.�� �National Emission Standards for Hazardous Air Pollutants (NESHAP) Method 319 compliant 3-stage dry particulate filter system (2 stages of panel filter, and 5-pocket bag filter) tested and certified in accordance with 40 CFR 63.750(o). A list of approved filter systems is attached. iii.�� �HEPA air filter. b.�� �Shall have a dust collection filter system (comprised of no fewer than six (6) cartridge filters of dimensions no smaller than 12.75"" x 30"" and efficiency no lower than 99.9% at 0.5 microns) mounted upstream of the NESHAP Method 319 compliant filter system per the attached diagram. c.�� �Shall have automated compressed air jet pulsation filter cleaning system for particulate removal/cleaning of dust collection filters. d.�� �Shall have compressed air filter cleaning system, Programmable Logic Controller controlled reverse jet pulse.� i.�� �Shall use compressed air of 1.5 SCF/pulse.� ii.�� �Shall have three (3) diaphragm valves.� iii.�� � Shall have three (3) pilot valves. e.�� �Shall have IEC/NEMA-sized combination start/stop motor starter. � i.�� �Starter is to be 208VAC/240VAC, 3 phase, with portable cord. � ii.�� �Cord is to have four (4) conductors, have 10 AWG wire size, be rubber, be black, be 100 ft long, and be 600V SOOW. f.�� �Shall have analog differential pressure measurement across all three (3) stages of NESHAP Method 319 compliant filter.� i.�� �Shall have ability to establish a set point to measure a pressure drop of up to one (1) inch of water column across the three (3) stages of filters (both panels and bag). ii.�� �Gauge shall have a span of at least three (3) inches of water. g.�� �Shall have HEPA after filters, 99.97% efficiency rating. 24"" x 24"" x 12"" (nominal). h.�� �Each HEPA filter must be metal encased with rubber or neoprene gasket. i.�� �Shall include four (4) extra sets of all stages of filters j.�� �Shall have Minimum Air Flow of 4,000 CFM. k.�� �Shall have Minimum of 5 HP, 3 Phase, 1750 RPM, TEFC Motor with non-overloading blower with overload protection l.�� �Shall have voltage requirements of 208/230V (with L15-30 Amp, 4 Prong Locking Male Plug). m.�� �Shall have 100� power cord n.�� �Shall have tow bar with lunette of toroidal steel construction. o.�� �Shall have epoxy coating (or equivalent protective coating) p.�� �Dimensional Requirements: i.�� �Shall have Maximum Height of 4-1/2 feet ii.�� �Shall have a Maximum Length of 10 feet (not including tow bar). iii.�� �Shall have a Maximum Width of 6 feet q.�� �Shall provide copy of schematic drawings and design specifications for approval prior to shipment. r.�� �Shall have two duct flanges capable of connecting to standard 12"" ID flexible reinforced duct on the dust-collecting side of the unit. s.�� �Must ship with quantity four (4) of 25� sections of flexible, reinforced, collapsible dust collection suction hose.� i.�� � Shall include two (2) connectors, each of which can connect quantity two (2) of 25� sections together. � ii.�� � Hoses shall be compatible with duct flanges installed on the dust-collecting side of the unit. t.�� �Shall have welded, heavy gauge, carbon steel construction. u.�� �Shall have minimum four (4) heavy duty, industrial grade casters. v.�� � Casters on the towbar side shall swivel and casters opposite the towbar shall be rigid. �All Casters shall:� i.�� �have shock absorbers� ii.�� �have wheels of solid material (i.e. rubber versus air filled) iii.�� �have wheels no smaller than 6� diameter iv.�� �be suitable for towing on rough surfaces v.�� �be lockable vi.�� �be suitable for being towed vii.�� �be rated for outdoor use viii.�� �be heavy duty. w.�� �Shall have multipurpose epoxy coating throughout collector. x.�� �Shall include One (1) Manual in PDF format, to be transmitted electronically.� 2.�� �Contractor shall furnish NESHAP Method 319 Filter System certification at time of bid submission. �Method 319 certified filters shall comply with the filter efficiencies in Table 4 (liquid) and 5 (solid) of 40 CFR 63.745.� 3.�� �Contractor shall provide documentation certifying that HEPA Air Filtration Unit provided is NESHAP Method 319 compliant per 40 CFR 63.745 and 40 CFR 63.746 by date of unit shipment.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/4078b70f4a144d2091c825e26c602f3f/view)
- Place of Performance
- Address: Tinker AFB, OK 73145, USA
- Zip Code: 73145
- Country: USA
- Zip Code: 73145
- Record
- SN06701466-F 20230603/230601230114 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |