Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JUNE 24, 2023 SAM #7879
SOLICITATION NOTICE

70 -- Custom Server

Notice Date
6/22/2023 12:04:08 PM
 
Notice Type
Solicitation
 
NAICS
541519 — Other Computer Related Services
 
Contracting Office
255-NETWORK CONTRACT OFFICE 15 (36C255) LEAVENWORTH KS 66048 USA
 
ZIP Code
66048
 
Solicitation Number
36C25523Q0292_1
 
Response Due
6/28/2023 10:00:00 AM
 
Archive Date
07/13/2023
 
Point of Contact
Michael P. Murphy, Phone: 9139461963
 
E-Mail Address
michael.murphy7@va.gov
(michael.murphy7@va.gov)
 
Small Business Set-Aside
SDVOSBC Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
 
Description
Objective The VA Saint Louis Health Care System intends to procure a custom-built server to host their GE Viewpoint software. This document highlights the technical specifications and services being requested by the facility for consideration towards purchase of the units. Vendors under this proposal shall provide all equipment and accessories, installation services, and project management support. Equipment Specifications Requirements PowerEdge R7XD Server PowerEdge R740XD Server (210-AKZR) Intel Xeon Gold 5217 3.0G, 8C/16T, 10.4GT/s, 11M Cache, Turbo, HT (115W) DDR4-2666 (338-BSDT) Intel Xeon Gold 5217 3.0G, 8C/16T, 10.4GT/s, 11M Cache, Turbo, HT (115W) DDR4-2666 (338-BSDT) (8) 8GB RDIMM, 3200MT/s, Single Rank (370-AEVO) (2) 480GB SSD SATA Read Intensive 6Gbps 512 2.5in Hot-plug AG Drive,3.5in HYB CARR, 1 DWPD (400-AXRJ) (5) 4TB 7.2K RPM NLSAS ISE 12Gbps 512n 3.5in Hard Drive (400-ASHY) Windows Server 2019 Standard,16CORE,FI,No Med, No CAL, Multi Language (634-BSFE) RAID 1 + RAID 5 (780-BCDR) Software Vendor shall ensure all software operating on the device provided is supported by the original manufacturer at time of delivery. For example, vendor shall not provide VA Saint Louis a device utilizing the Windows XP or Windows 7 operating system as they are no longer Microsoft supported. Proprietary software systems are acceptable so long as vendor supports the version provided to VA Saint Louis and it is the newest version at time of delivery. Access to all software shall be provided to VA Saint Louis in situations where re-installation is necessary. Software shall be provided to VA Saint Louis with unlimited perpetual licensing for the supported life of the device. In cases where vendor insists on utilizing a licensing fee model this should be noted in the bid provided for VA Saint Louis consideration. Cerner Compatibility All vendors providing a bid to this requirement shall provide a Cerner compatibility statement from the OEM of the equipment that they are proposing to the VA Saint Louis Health Care System. This statement will include an OEM attestation that the product proposed is Cerner verified and provide a list of healthcare organizations that have deployed the project with the Cerner EHR. The statement will also include any relevant information as to what data can be transmitted to Cerner. This statement will be dated within 60 days of the quote being provided to ensure it is recent and accurate. The statement will provide an OEM point of contact who can be reached to further discuss any questions or concerns over Cerner compatibility. If the device/system being proposed does not connect to the network or medical record the vendor shall note this in their proposal. Vendor bids that do not include a Cerner compatibility statement directly from the OEM will be discarded from consideration. Installation and Assembly Vendor shall be responsible for assembly and installation of systems after notification from VA Saint Louis Biomedical Engineering that it has been delivered to station. Installation shall include implementation and testing of all purchased interfaces to VA electronic systems in coordination with Clinical Staff, Biomedical Engineering staff, O&IT staff, and others identified as needed. Install shall include unboxing and transportation of equipment to final use location. Assembly and install shall occur within 30 days of delivery to station. Vendor shall provide all necessary accessories, cables, adaptors, etc. to deliver a fully functional clinical device. Training Vendor shall provide on-site clinical/applications training for relevant VA Saint Louis staff members. Vendor shall provide introductory system/maintenance training to VA Saint Louis Biomedical Engineering staff during installation. Vendor shall include all costs for travel to provide this training in their proposal. Vendor shall coordinate all installation and training dates with VA Saint Louis specified Biomedical Engineering POC who will communicate internally with clinical staff. Warranty and Service Service and Operator Manuals � The vendor shall provide the following documentation for the proposed system: Two (2) copies of operator's instruction manuals per unit purchased Two (2) copies of complete technical service manuals including detailed troubleshooting guides, necessary diagnostic software, service keys, schematic diagrams, parts lists, and any other resources available to the manufacturer�s service technicians. Two (2) copies of a system manager�s manual outlining back-up procedures, managing privilege group limits, routine tasks, etc. Warranty � The system, all accessories, and all software shall be covered under the manufacturer�s warranty and shall include all parts and labor for at least one year following acceptance by the VAMC. A manufacturer�s factory-trained Field Service Engineer shall perform installation and maintenance during the warranty period. The warranty period shall not begin until after the VA Saint Louis Biomedical Engineering POC has accepted the products delivery, installation, and functionality. The warranty shall include all manufacturer recommended Preventive Maintenance procedures for its duration. All available software updates and security patches will be made available to the VA Saint Louis during the warranty period. Vendor shall provide response to applications and technical calls within 8 hours. Vendor shall ship replacement parts within 48 hours of identifying necessity by VA Saint Louis Biomedical Engineering staff. Other Features Value added features in the vendor�s proposal that will be considered include but are not limited to: Options for Trade-in of existing equipment shall be proposed in bid package Extended Warranty options shall be outlined in bid package Service and Biomedical training options shall be outlined in bid package Options for this training should include all registration, travel, and lodging costs when possible Cerner Compatibility All vendors providing a bid to this requirement shall provide a Cerner compatibility statement from the OEM of the equipment that they are proposing to the VA Saint Louis Health Care System. This statement will include an OEM attestation that the product proposed is Cerner verified and provide a list of healthcare organizations that have deployed the project with the Cerner EHR. The statement will also include any relevant information as to what data can be transmitted to Cerner. This statement will be dated within 60 days of the quote being provided to ensure it is recent and accurate. The statement will provide an OEM point of contact who can be reached to further discuss any questions or concerns over Cerner compatibility. If the device/system being proposed does not connect to the network or medical record the vendor shall note this in their proposal. Vendor bids that do not include a Cerner compatibility statement directly from the OEM will be discarded from consideration. Installation and Assembly Vendor shall be responsible for assembly and installation of systems after notification from VA Saint Louis Biomedical Engineering that it has been delivered to station. Installation shall include implementation and testing of all purchased interfaces to VA electronic systems in coordination with Clinical Staff, Biomedical Engineering staff, O&IT staff, and others identified as needed. Install shall include unboxing and transportation of equipment to final use location. Assembly and install shall occur within 30 days of delivery to station. Vendor shall provide all necessary accessories, cables, adaptors, etc. to deliver a fully functional clinical device. Training Vendor shall provide on-site clinical/applications training for relevant VA Saint Louis staff members. Vendor shall provide introductory system/maintenance training to VA Saint Louis Biomedical Engineering staff during installation. Vendor shall include all costs for travel to provide this training in their proposal. Vendor shall coordinate all installation and training dates with VA Saint Louis specified Biomedical Engineering POC who will communicate internally with clinical staff. Warranty and Service Service and Operator Manuals � The vendor shall provide the following documentation for the proposed system: Two (2) copies of operator's instruction manuals per unit purchased Two (2) copies of complete technical service manuals including detailed troubleshooting guides, necessary diagnostic software, service keys, schematic diagrams, parts lists, and any other resources available to the manufacturer�s service technicians. Two (2) copies of a system manager�s manual outlining back-up procedures, managing privilege group limits, routine tasks, etc. Warranty � The system, all accessories, and all software shall be covered under the manufacturer�s warranty and shall include all parts and labor for at least one year following acceptance by the VAMC. A manufacturer�s factory-trained Field Service Engineer shall perform installation and maintenance during the warranty period. The warranty period shall not begin until after the VA Saint Louis Biomedical Engineering POC has accepted the products delivery, installation, and functionality. The warranty shall include all manufacturer recommended Preventive Maintenance procedures for its duration. All available software updates and security patches will be made available to the VA Saint Louis during the warranty period. Vendor shall provide response to applications and technical calls within 8 hours. Vendor shall ship replacement parts within 48 hours of identifying necessity by VA Saint Louis Biomedical Engineering staff. Other Features Value added features in the vendor�s proposal that will be considered include but are not limited to: Options for Trade-in of existing equipment shall be proposed in bid package Extended Warranty options shall be outlined in bid package Service and Biomedical training options shall be outlined in bid package Options for this training should include all registration, travel, and lodging costs when possible Delivery Vendor shall deliver purchased equipment within 30 business days of receiving completed Contracting package from the VISN 15 Contracting Officer. If delivery delays occur vendor shall notify the Contracting Officer and the VA Saint Louis Biomedical Engineering POC. Delivery will be to one of the two VA Saint Louis Health Care System main campuses. Vendor shall coordinate exact delivery location with the Contracting Officer and VA Saint Louis Biomedical Engineering POC at the time of the purchase. Vendor will ensure that equipment is sent to the Attention of Biomedical Engineering and will include the VA Saint Louis PO Number on the shipping label. Delivery of oversized, palletized orders or orders that contain a large number of components will be coordinated with VA Saint Louis Biomedical Engineering POC who will communicate internally with Warehouse Staff.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/0ced13abff064a5db9450de2ec8779b8/view)
 
Place of Performance
Address: Saint Louis, MO 63106, USA
Zip Code: 63106
Country: USA
 
Record
SN06725291-F 20230624/230622230119 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.