Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JULY 02, 2023 SAM #7887
AWARD

J -- FY23: Tier2 NRM (PROJ: 546-21-110) BB - Upgrade HVAC System in the Utility Plant BLD 44

Notice Date
6/30/2023 4:15:02 AM
 
Notice Type
Award Notice
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
248-NETWORK CONTRACT OFFICE 8 (36C248) TAMPA FL 33637 USA
 
ZIP Code
33637
 
Solicitation Number
36C24823R0123
 
Archive Date
07/14/2023
 
Point of Contact
Apolinar Vargas, Phone: 7867905241
 
E-Mail Address
apolinar.vargas@va.gov
(apolinar.vargas@va.gov)
 
Small Business Set-Aside
SDVOSBC Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
 
Award Number
36C24823C0060
 
Award Date
06/29/2023
 
Awardee
MILICON INC Sunrise FL 33326 USA
 
Award Amount
2834.79
 
Description
The main objective is to replace and upgrade the Heating, Ventilation, and Air Conditioning (HVAC) components in the Utility Plant in Building 44. The Contractor shall be responsible for the removal and replacement of duct and piping associated with the building HVAC, repairs and improvements to the chilled water system to include removal and replacement of four (4) existing 60 HP horizontal split case chilled water pumps (primary pumps), and removal and replacement of twelve (12) existing end suction chilled water pumps (secondary pumps). Identify and correct corrosion on the condenser water piping. Replacement of insulation on chilled water piping. Repaint all condenser water piping and remove corrosion. Limited insulation shall be replaced where required for installation of new pumps. The electrical power connected to existing mechanical units shall be demolished back to source. All exiting conductors and accessories shall be demolished. Conduits concealed in concrete walls or slabs shall be abandoned. Wiring in abandoned conduits shall be demolished back to source. Existing circuit breakers and disconnect switches shall be demolished back to source. Existing conductors shall be pulled back to the branch circuit protective device and such device shall be identified as a spare. The existing conduit shall be reused if adequate for the new circuit breaker to be installed during construction as per the 100% Final Design, Narrative and Specifications. The contractor shall visually inspect the HVAC system currently installed in building 44 of the VA Miami Hospital before starting work to clarify any questions regarding space, mechanical, electrical, or any other special requirement. The contractor is responsible for the professional quality, technical accuracy, and coordination required of all equipment used and additional work or materials related to performing work herein.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/2bead2ee1d994318bdd141aefcf9becd/view)
 
Place of Performance
Address: Miami, FL 33125, USA
Zip Code: 33125
Country: USA
 
Record
SN06733343-F 20230702/230630230038 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.