SOURCES SOUGHT
66 -- Campbell Scientific HygroVUE10 Temperature/RH Probes and Accessories
- Notice Date
- 6/30/2023 12:16:37 PM
- Notice Type
- Sources Sought
- NAICS
- 334513
— Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables
- Contracting Office
- DEPT OF COMMERCE NOAA SEATTLE WA 98115 USA
- ZIP Code
- 98115
- Solicitation Number
- NRMJ20002301028SML
- Response Due
- 7/10/2023 11:00:00 AM
- Archive Date
- 07/25/2023
- Point of Contact
- Stephanie Long, Phone: 3035786768
- E-Mail Address
-
stephanie.long@noaa.gov
(stephanie.long@noaa.gov)
- Description
- Solicitation Number: NRMJ20002301028SML Notice Type: Sources Sought Synopsis Title: Campbell Scientific HygroVUE10 Temperature/RH Probes and Accessories Response Date: July 10, 2023 This is a SOURCES SOUGHT SYNOPSIS and is not a pre-solicitation announcement. The purpose of this Market Research and Sources Sought Notice is to gain knowledge of potential qualified U.S. Domestic businesses, which could include Small Business, HUBZone, 8(a), Service Disabled Veteran Owned, Women Owned Small Business firms and even Large Businesses. Responses to this Sources Sought Synopsis will be used by the Government in making appropriate acquisition decisions. The National Oceanic and Atmospheric Administration (NOAA), Oceanic and Atmospheric Research (OAR), Earth Systems Research Laboratories (ESRL), Physical Sciences Laboratory (PSL) is currently maintaining a network of meteorological weather monitoring systems in the state of California for the California Department of Water Resources (DWR) and other projects. A critical component of these systems is the temperature/humidity probe that records constant temperature and humidity readings for inclusion to the datalogger that is monitoring weather at each site. The current temperature/humidity probes are manufactured by Campbell Scientific, and the PSL is in need of replacements that are compatible in all aspects (form, fit, and function). INTENDED USE/PURPOSE: The HygroVUE10 offers a combined temperature and relative humidity element in an advanced digital sensor that is ideal for weather networks. The electronics within the sensor provide accurate measurements, and the sensor is easy to use. The digital SDI-12 output allows a simple connection and measurement by many data logging systems. The sensor housing is designed to withstand permanent exposure to various weather conditions and to fit inside a range of radiation shields (including compact shields). A temperature/relative humidity sensor like the Campbell Scientific HygroVUE10 is required to meet the technical specifications and provide the level of accuracy needed for the PSL�s tolerances. SPECIAL REQUIREMENTS/ESSENTIAL SALIENT FEATURES: SPECIFICATIONS Sensing Element SHT35 modified by Campbell Scientific Communication Standard SDI-12 V1.4 (responds to a subset of commands) Supply Voltage 7 to 28 Vdc EMC Compliance Tested and conforms to IEC61326:2013. Standard Operating Temperature Range -40� to +70�C Main Housing Material UV stable, white PET-P Electronics Sealing Classification IP67 Sensor Protection Outer glass-filled polypropylene cap fitted with a stainless-steel mesh dust filter with nominal pore size of 99.99% for particles of 200 nm or larger size. Sensor Connector M12, male, 4-pole, A-coded Cable Polyurethane sheathed, screened cable, nominal diameter 4.8 mm (0.19 in.) Field-Replaceable Chip or Recalibrate Field-replaceable chip Sensor Cap Diameter 12.5 mm (0.5 in.) Body Diameter at Connector 18 mm (0.7 in.) Length 180 mm (7.1 in.) without cable fitted Sensor Body Weight 50 g (1.8 oz) Weight 250 g (8.8 oz) with 5 m (16.4 ft) cable RELATIVE HUMIDITY Measurement Range 0 to 100% RH Accuracy �2% (at 25�C, over the range 80 to 100% RH) -NOTE- The accuracy figures quoted are the 95% confidence limits relative to factory standards. �1.5% (at 25�C, over the range 0 to 80% RH) Short-Term Hysteresis < �1% RH Additional Errors at Other Temperatures < �1% RH (over -40� to +60�C) Long-Term Stability �0.5% per year (maximum drift in clean air conditions) Reported Resolution 0.001% RH Repeatability 0.05% RH (3? noise level) Response Time with Filter < 20 s (63% response time in still air) AIR TEMPERATURE Measurement Range -40�C to +70�C -NOTE- The accuracy figures quoted are the 95% confidence limits relative to factory standards. Accuracy �0.1�C (over the range 20 to 60�C) �0.2�C (over the range -40 to +70�C) Long-Term Drift < 0.03�C per year Reported Resolution 0.001�C Repeatability 0.04�C (3? noise level) Response Time with Filter < 130 s (63% response time in air moving at 1 m/s) Calibration Traceability NIST and NPL standards MAXIMUM CURRENT DRAIN Quiescent 50 ?A During Measurement 0.6 mA (takes 0.5 s) DELIVERY SCHEDULE: Deliver by September 30, 2023. The North American Industry Classification Code (NAICS) is 344513 with a size standard of 750 employees. Interested firms shall provide, in writing, a brief narrative (no more than 3 pages in length) and documentation to support your firm�s capability and experience meeting the requirements herein and include your firm�s name, address, point of contact, telephone number, UEID Number, CCR CAGE Number, business type and size (i.e., small, large, non-profit, educational, etc.). Any response that does not include this information will not be considered. The Government will review your response to determine if your firm has the experience, knowledge and capability to provide the items as specified above. This request for information does not constitute a commitment, implied or otherwise, that a procurement action will be issued. Nor does this request for information constitute a commitment, implied or otherwise, that any procurement action may be issued for the Government�s requirements. No entitlement to payment of direct or indirect costs or charges by the Government will arise because of the submission of contractor�s information. The Government shall not be liable for or suffer any consequential damages for proprietary information not properly identified. Proprietary information will be safeguarded in accordance with the applicable Government regulations. All contractors doing business with the Government are required to be registered and active with the System for Award Management (SAM) website. NOTE: THIS SYNOPSIS IS NOT CONSIDERED A REQUEST FOR PROPOSAL BUT A REQUEST FOR INFORMATION ONLY. No solicitation document is available. No contract will be awarded based on responses received to this notice.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/7bc28e6959e84bc2a35514e9f1c63a83/view)
- Place of Performance
- Address: USA
- Country: USA
- Country: USA
- Record
- SN06734799-F 20230702/230630230049 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |