J -- Kitchen Exhaust Hood Repairs and Duct Cleaning - 47PF0023R0081

Notice Date
7/13/2023 10:02:53 AM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
PBS R5 CHICAGO IL 60604 USA
 
ZIP Code
60604
 
Solicitation Number
RIN12083
 
Response Due
8/11/2023 9:00:00 AM
 
Archive Date
08/26/2023
 
Point of Contact
Shekita M Wimberly, Phone: 3133179615, Fax: 3138457106
 
E-Mail Address
shekita.wimberly@gsa.gov
(shekita.wimberly@gsa.gov)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
The contractor shall perform a pre-alteration test and balance of the existing kitchen exhaust system. Provide a report with a list of deficiencies. The contractor shall perform cleaning of the kitchen exhaust system in compliance with NFPA standards. Observe the vertical ducts for any fluid that escapes the kitchen exhaust ductwork. Provide a report. Visit site to verify the documents reasonably reflect the actual conditions. The contractor shall verify that adequate physical space is available to perform work. Verify the removal and relocation of items necessary to complete work. Develop shop drawings and schedule trade efforts to accommodate the project. Remove the welded kitchen exhaust ductwork from the ceiling of the second floor. Remove any finishes, utilities, equipment, conduits to accommodate demolition and providing new reconfigured kitchen exhaust duct. Provide new kitchen exhaust duct with a reconfigures routing. Connect to the existing vertical black iron exhaust duct and existing kitchen exhaust hood. Provide access panels, supports, UL listed kitchen exhaust duct, etc. Perform leakage test, test and balance and any testing required by kitchen exhaust manufacturer. Submit reports. Re-install ceilings, utilities, equipment, ducts, conduits that were removed to accommodate efforts to demolish and replace kitchen exhaust duct. Relocate items conflicting with the new routing. Provide closeout documents consistent with the front-end specifications. The contractor shall perform efforts when the building is closed to the public. The bid shall reflect working at these times. The contractor shall cordon off the area of work to allow for the partial use of food prep spaces during construction. Provide temporary partitions, dust protection, access doors, etc.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/d829455e373443b489ba58d5dcf880f8/view)
 
Place of Performance
Address: Hammond, IN 46320, USA
Zip Code: 46320
Country: USA
 
Record
SN06747285-F 20230715/230713230051 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.